FEI 3002600322
FDA has 5 inspections on file for Laboratorios Jaloma S.A. de C.V. in Guadalajara, Mexico (FEI 3002600322), from 2011 to 2025. The latest ended on and was classified OAI, official action indicated. FDA has issued 3 warning letters under this FEI, the latest on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two FOIA requests have asked FDA for this inspection's 483.
14 import refusals are filed under this FEI, the latest on . FDA’s Red Lists for Import Alerts 66-40, 66-78 and 79-01 name this firm at this address. FDA printed no FEI on the entries. No court action is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 5, 2011–2025
- 2 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 5
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 2 requests, latest Feb 6, 2026
- Import refusals
- 14 refusals
- Import alerts
- 66-40, 66-78, 79-01Red List
- Matched on FDA’s firm name and street address
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written record not kept of program and validation data
A written record of the program along with appropriate validation data has not been maintained in situations where backup data is eliminated by computerization or other automated processes. Electronic records are used, but they do not meet systems validation requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
Actual yield, % of theoretical yield
The batch production and control records do not include a statement of the actual yield and percentage of theoretical yield at appropriate stages of processing for each batch of drug product produced.
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Show 2 more citations
Washing and toilet facilities are deficient
Washing and toilet facilities lack hot and cold water.
Identification of Each Lot in Each Shipment
Each lot in each shipment received was not identified with a distinctive code for each container or grouping of containers for components.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance17 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing and processing of the drug product.
Quarantined Drug Products Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the quarantine storage of drug products prior to release.
Show 12 more citations
Status of Each Lot Identified
Each lot of components and closures was not appropriately identified as to its status in terms of being quarantined, approved or rejected.
Label storage access limited to authorized personnel
Access to the storage area for labels and labeling materials is not limited to authorized personnel.
Storage off Floor, Spaced Suitably
Bagged or boxed components of drug product containers and closures are not suitably spaced to allow cleaning and inspection.
Identifying Containers Sampled
Markings of containers from which samples have been taken are deficient in that they do not show that samples have been removed from them.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions.
Washing and toilet facilities are deficient
Washing and toilet facilities lack hot and cold water.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Documentation of Batch Investigations
The batch production and control records are deficient in that they do not include documentation of batch investigations performed.
Defined areas of adequate size for operations
The separate or defined areas necessary to prevent contamination or mix-ups are deficient.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Feb 6, 2026. Each one asked for a Form 483.
Inspection ending Dec 19, 2025OAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Mar 20, 2026. FDAgent holds no copy that FDA posted.
- Feb 6, 2026FDA-FOIA-2026-1272Form 483· 1 of 2 sitesRecords released
- Date not givenFDA-FOIA-2026-4300Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 17 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.52Washing and toilet facilities2 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 3
- 21 CFR 211.80General requirements2 of 3
- 21 CFR 211.186Master production and control records2 of 3
- 21 CFR 211.188Batch production and control records2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.42Design and construction features1 of 3
- 21 CFR 211.56Sanitation1 of 3
Show all 17
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 3
- 21 CFR 211.103Calculation of yield1 of 3
- 21 CFR 211.122Materials examination and usage criteria1 of 3
- 21 CFR 211.160General requirements1 of 3
- 21 CFR 211.166Stability testing1 of 3
- 21 CFR 211.180General requirements1 of 3
- 21 CFR 211.182Equipment cleaning and use log1 of 3
- 21 CFR 211.192Production record review1 of 3
- 21 CFR 211.194Laboratory records1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002600322, one row per refused product line.
14 refusals from 2017-04-04 to 2026-01-21 · charged DRUG GMPS on 12, UNAPPROVED on 7 · FDA sample analysis on 3
FDA firm profile- 2026-01-21
MISCELLANEOUS PATENT MEDICINES, ETC.66VCB99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-2726959-0/150003/1
- 2026-01-21
MISCELLANEOUS PATENT MEDICINES, ETC.66VCB99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-2726959-0/140003/1
- 2023-09-07
SUPPRESSANT N.E.C.66FDY99
DR QUALITY 501(b), 801(a)(3); ADULTERATION
REDUCED 501(d)(1), 801(a)(3); ADULTERATION
INSANITARY 501(a)(2)(A), 801(a)(3); ADULTERATION
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
SUBSTITUTE 501(d)(2), 801(a)(3); ADULTERATION
DR QUALITC 501(c), 801(a)(3); ADULTERATION
Division of Southeast Imports799-6626814-6/11/1
- 2022-10-03
GENTIAN VIOLET (ANTI-INFECTIVE, TOPICAL)62FCY14
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast Imports799-1090658-5/31/1
- 2022-03-03
ETHYL ALCOHOL (ANTI-MICROBIAL)62HAL05
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports705-1188045-5/21/1
Show 9 more
- 2022-03-03
ETHYL ALCOHOL (ANTI-MICROBIAL)62HAL05
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports705-1188045-5/11/1
- 2022-02-17
ETHYL ALCOHOL (ANTI-MICROBIAL)62HAL05
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
SUBSTITUTE 501(d)(2), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
FDA sample analysis
Division of Southwest Imports705-1188536-3/31/1
- 2022-02-17
ETHYL ALCOHOL (ANTI-MICROBIAL)62HAL05
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
SUBSTITUTE 501(d)(2), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
FDA sample analysis
Division of Southwest Imports705-1188536-3/21/1
- 2022-02-17
ETHYL ALCOHOL (ANTI-MICROBIAL)62HAL05
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
SUBSTITUTE 501(d)(2), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
FDA sample analysis
Division of Southwest Imports705-1188536-3/11/1
- 2021-06-09
ETHYL ALCOHOL (ANTI-MICROBIAL)62HBL05
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest ImportsWC1-9476105-0/21/1
- 2020-09-11
ETHYL ALCOHOL (ANTI-MICROBIAL)62HAL05
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest ImportsWC1-9487630-4/11/1
- 2020-09-10
ETHYL ALCOHOL (ANTI-MICROBIAL)62HAL05
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest ImportsWC1-9487631-2/11/1
- 2017-09-28
LISINOPRIL (ANTI-HYPERTENSIVE)62CDC65
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-2399222-3/21/1
- 2017-04-04
LISINOPRIL (ANTI-HYPERTENSIVE)62CCH65
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-9856843-5/11/3
Import alerts
FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.
- 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov
Date published 2026-04-23
- FDA’s entry
- Laboratorios Jaloma S.A. de C.V. · Calle Aquiles Serdan No. 438, Colonia Oblatos, Guadalajara, Jalisco MEXICO
- FDA’s inspection record for FEI 3002600322
- Laboratorios Jaloma S.A. de C.V. · Calle Aquiles Serdan No. 438, Colonia Oblatos, Guadalajara, Mexico
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
15 products
- 54 - D - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx 1 Ingr
- 54 - E - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx Comb Ingr
- 54 - F - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx 1 Ingr
Show 12 more products
- 54 - G - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx Comb Ingr
- 54 - I - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Investigational
- 55 - - - --Pharm Necess & Ctnr For Drug/Bio
- 56 - - - --Antibiotics (Human/Animal)
- 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
- 60 - - - --Human and Animal Drugs
- 61 - - - --Human and Animal Drugs
- 62 - - - --Human and Animal Drugs
- 63 - - - --Human and Animal Drugs
- 64 - - - --Human and Animal Drugs
- 65 - - - --Human and Animal Drugs
- 66 - - - --Human and Animal Drugs
- 66-78Red ListDetention Without Physical Examination of Drugs, Based Upon Analytic Test ResultsImport alert pageAlert on fda.gov
Date published 2020-08-03
- FDA’s entry
- Laboratorios Jaloma S.A. de C.V. · Calle Aquiles Serdan No. 438, Colonia Oblatos, Guadalajara, Jalisco MEXICO
- FDA’s inspection record for FEI 3002600322
- Laboratorios Jaloma S.A. de C.V. · Calle Aquiles Serdan No. 438, Colonia Oblatos, Guadalajara, Mexico
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
10 products
- 55 - - - --Pharm Necess & Ctnr For Drug/Bio
- 56 - - - --Antibiotics (Human/Animal)
- 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
Show 7 more products
- 60 - - - --Human and Animal Drugs
- 61 - - - --Human and Animal Drugs
- 62 - - - --Human and Animal Drugs
- 63 - - - --Human and Animal Drugs
- 64 - - - --Human and Animal Drugs
- 65 - - - --Human and Animal Drugs
- 66 - - - --Human and Animal Drugs
- 79-01Red ListDetention Without Physical Examination of Topical/External Bandages, Dressings, Gauzes/Sponges and Cotton Pads Due to Microbiological ContaminationImport alert pageAlert on fda.gov
Date published 2009-09-16
- FDA’s entry
- Laboratorios Jaloma S.A. de C.V. · Calle Aquiles Serdan No. 438, Colonia Oblatos, Guadalajara, Jalisco MEXICO
- FDA’s inspection record for FEI 3002600322
- Laboratorios Jaloma S.A. de C.V. · Calle Aquiles Serdan No. 438, Colonia Oblatos, Guadalajara, Mexico
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
1 product
- 79 N - - ABGauze/Sponge, Nonresorbable For External Use
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002600322 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002600322. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.