Haw Par Healthcare Limited
2 Chia Ping Road, #09-03 Haw Par Tiger Balm Building, Singapore, Singapore
FEI 3001432470DUNS 659207039
FDA has 6 inspections on file for Haw Par Healthcare Limited in Singapore, Singapore (FEI 3001432470), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
The most recent OAI inspection ended on Aug 19, 2022. FDA has issued 2 warning letters under this FEI, the latest on (CDER). 4 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
10 regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is Haw Par Healthcare Ltd. (D-U-N-S 659207039).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2009–2024
- 3 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 5 of 6
- Form 483s posted by FDA
- None held for this FEI
- Import refusals
- 4 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Status of Each Lot Identified
Each lot of components was not appropriately identified as to its status in terms of being quarantined, approved or rejected.
Reason for Not Conducting Complaint Investigation
Complaint records are deficient in that they do not document the reason and the individual making the decision not to conduct a complaint investigation.
Written Procedures Not Followed
Written procedures are not followed for the approval of components.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 2 more citations
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Lot or control number assigned
The drug product is not identified with a lot or control number that permits the determination of the history of the manufacture and control of the batch.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Show 3 more citations
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
SOPs not followed / documented
Written production and process control procedures are not documented at the time of performance.
Approve or reject procedures or specs
The quality control unit lacks responsibility to approve all procedures or specifications impacting on the quality of drug products.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Show 9 more citations
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Buildings not maintained in good state of repair
Buildings used in the manufacturing of a drug product are not maintained in a good state of repair.
Written Procedures Not Followed
Written procedures are not followed for the approval of components.
Lot or control number assigned
The drug product is not identified with a lot or control number that permits the determination of the history of the manufacture and control of the batch.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Reserve drug product sample quantity - all tests
The reserve sample of drug product does not consist of at least twice the quantity necessary to perform all the required tests of drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of insecticides designed to prevent the contamination of equipment, components, drug product containers, packaging, labeling materials and drug products.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Show 1 more citation
Calibration - at intervals, written program, remedial action
The calibration of apparatus is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Storage conditions
Drug product expiration dates are not related to the storage conditions stated on the labeling, as determined by stability studies.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, and packing of a drug product lack the education required to perform their assigned functions.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Show 3 more citations
Identification of Persons Performing Significant Steps
The batch production and control records are deficient in that they do not include identification of persons supervising and checking each significant step in the operation.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Postmarket Surv. and EpidemiologyCitations not published
Regulations FDA cited here
The 25 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.111Time limitations on production3 of 5
- 21 CFR 211.160General requirements3 of 5
- 21 CFR 211.192Production record review3 of 5
- 21 CFR 211.22Responsibilities of quality control unit2 of 5
- 21 CFR 211.67Equipment cleaning and maintenance2 of 5
- 21 CFR 211.80General requirements2 of 5
- 21 CFR 211.100Written procedures; deviations2 of 5
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 5
Show all 25
- 21 CFR 211.130Packaging and labeling operations2 of 5
- 21 CFR 211.142Warehousing procedures2 of 5
- 21 CFR 211.165Testing and release for distribution2 of 5
- 21 CFR 211.186Master production and control records2 of 5
- 21 CFR 211.25Personnel qualifications1 of 5
- 21 CFR 211.56Sanitation1 of 5
- 21 CFR 211.58Maintenance1 of 5
- 21 CFR 211.63Equipment design, size, and location1 of 5
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 5
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 5
- 21 CFR 211.125Labeling issuance1 of 5
- 21 CFR 211.137Expiration dating1 of 5
- 21 CFR 211.166Stability testing1 of 5
- 21 CFR 211.170Reserve samples1 of 5
- 21 CFR 211.188Batch production and control records1 of 5
- 21 CFR 211.194Laboratory records1 of 5
- 21 CFR 211.198Complaint files1 of 5
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3001432470, one row per refused product line.
4 refusals from 2019-03-14 to 2023-04-11 · charged DRUG GMPS on 3, FRNMFGREG on 1 · no FDA sample analysis
FDA firm profile- 2023-04-11
ANALGESIC, N.E.C.60LBJ99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of West Coast ImportsEFG-0047598-3/11/1
- 2023-03-29
ANALGESIC, N.E.C.60LBY99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of West Coast ImportsK80-5124291-6/11/2
- 2023-03-29
ANALGESIC, N.E.C.60LBY99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of West Coast ImportsK80-5124291-6/11/1
- 2019-03-14
MENTHOL (ANTI-PRURITIC)62MAY08
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of Northeast Imports9K9-1003705-7/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- Haw Par Healthcare Ltd.D-U-N-S 659207039
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3001432470 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3001432470. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.