Straight Arrow Products, Inc.
2020 Highland Ave, Bethlehem, Pennsylvania, United States
FEI 2244008
FDA has 6 inspections on file for Straight Arrow Products, Inc. in Bethlehem, Pennsylvania (FEI 2244008), from 2010 to 2022. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 6, 2010–2022
- 0 OAI · 5 VAI · 1 NAI
- Inspections with 483 observations shown
- 5 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest Sep 15, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards.
Complaint Investigation/Follow-Up Findings
Complaint records are deficient in that they do not include the findings of the investigation and follow-up.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Show 2 more citations
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written records kept in individual logs
Written records of major equipment maintenance and use are not included in individual equipment logs.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Lab controls established, including changes
The establishment of specifications, standards, sampling plans, test procedures, and laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance15 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Identifying Sample Containers
Sample container identification of sampled item is deficient in that it does not include the container from which the sample was taken and date on which the sample was taken.
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Variation in the Amount of Components Used
The master production and control records are deficient in that they lack a justification for the variation in the amount of components used in the preparation of a dosage form.
Incoming material area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the receipt, identification, storage, and withholding from use of components, drug product containers, closures, and labeling pending sampling, testing, or examination by the quality control unit before release for manufacturing or packaging.
Show 10 more citations
Description of containers, labels, et. al.
Master production and control records lack a description of the drug product containers, closures and packaging materials, a specimen or copy of each label and all other labeling, and the signatures and dates entered by the person or persons responsible for the approval of labeling.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure.
Identifying Containers Sampled
Markings of containers from which samples have been taken are deficient in that they do not show that samples have been removed from them.
Review of representative number of batches
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Theoretical Yield and Percentages
The master production and control records are deficient in that they do not include a statement of theoretical yield and minimum, maximum, and yield percentages.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of drug product containers and closures.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Sep 15, 2025. It asked for a Form 483.
Inspection ending Nov 22, 2019VAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 8, 2025. FDAgent holds no copy that FDA posted.
- Sep 15, 2025FDA-FOIA-2025-10924Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 18 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.63Equipment design, size, and location3 of 5
- 21 CFR 211.80General requirements3 of 5
- 21 CFR 211.67Equipment cleaning and maintenance2 of 5
- 21 CFR 211.100Written procedures; deviations2 of 5
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 5
- 21 CFR 211.192Production record review2 of 5
- 21 CFR 211.25Personnel qualifications1 of 5
- 21 CFR 211.42Design and construction features1 of 5
Show all 18
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 5
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 5
- 21 CFR 211.137Expiration dating1 of 5
- 21 CFR 211.160General requirements1 of 5
- 21 CFR 211.166Stability testing1 of 5
- 21 CFR 211.180General requirements1 of 5
- 21 CFR 211.182Equipment cleaning and use log1 of 5
- 21 CFR 211.186Master production and control records1 of 5
- 21 CFR 211.194Laboratory records1 of 5
- 21 CFR 211.198Complaint files1 of 5
Other FEIs recorded as Straight Arrow Products, Inc.
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Straight Arrow Products, Inc.FEI 3014727651Easton, Pennsylvania, United States
Last inspected 2024-10-15VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2244008 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2244008. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.