Continental Manufacturing Chemist, Inc.
912 S State St, Madrid, Iowa, United States
FEI 1910648DUNS 005278007
FDA has 7 inspections on file for Continental Manufacturing Chemist, Inc. in Madrid, Iowa (FEI 1910648), from 2009 to 2023. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
11 regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and repacking, through Dec 31, 2026. Its registrant is Continental Manufacturing Chemist, Inc. (D-U-N-S 005278007).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 7, 2009–2023
- 3 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 7 of 7
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Representative Samples
Representative samples are not taken of each shipment of each lot of components for testing or examination.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Rejecting When Specifications Not Met
Failure to reject any lot of components and drug product containers that did not meet the appropriate written specifications for identity, strength, quality, and purity.
Calibration/Inspection/Checking not done
Routine calibration, inspection and checking of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Review of representative number of batches
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Show 5 more citations
Labeling Control Records and Label Copies
The batch production and control records are deficient in that they do not include copy of labeling.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are not written or followed and deficiently written or followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Quarantine - actual practice
Drug products are not quarantined before being released by the quality control unit.
Deviations from laboratory control requirements
Deviations from written test procedures and laboratory mechanisms are not recorded.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Sampling and testing plans not followed
Written procedures for sampling and testing plans are not followed for each drug product.
Record maintenance 1 year (except exempt OTC)
All records of production, control, and distribution associated with a batch of drug product are not maintained at least one (1) year after the expiration date.
GMP Training Frequency
GMP training is not conducted to assure that employees remain familiar with CGMP requirements applicable to them.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Show 2 more citations
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Retest of approved components/containers/closures
Approved components are not retested or reexamined as appropriate for identity, strength, quality and purity after storage for long periods with subsequent approval or rejection by the quality control unit.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit and reviewed and approved by the quality control unit.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Sampling and testing plans not described
Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Show 9 more citations
Components withheld from use pending release
Each lot of components is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Labels and labeling stored separately
Labels and other labeling materials are not stored separately with suitable identification for each different drug product, strength, dosage form or quantity of contents.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Identification of containers, lines, equipment
All compounding and storage containers used during the production of a batch of drug product is not properly identified at all times to indicate contents and the phase of processing of the batch.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Test methods
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established.
Written record of investigation incomplete
Written records of investigations into the failure of a batch or any of its components to meet specifications do not include the conclusions and follow-up.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Test methods
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include parameters relevant to the operation.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Drug products-sampling procedures/specifications
Laboratory controls do not include a determination of conformance to appropriate specifications for drug products.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include maintenance and cleaning schedules and description in sufficient detail of methods, equipment and materials used.
Show 7 more citations
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair.
Instruments, apparatus, et. al. not meeting specs
The use of instruments not meeting established specifications was observed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Written records kept in individual logs
Written records of major equipment maintenance and use are not included in individual equipment logs.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Regulations FDA cited here
The 21 sections of 21 CFR in FDA’s published citations for this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance5 of 7
- 21 CFR 211.165Testing and release for distribution5 of 7
- 21 CFR 211.192Production record review5 of 7
- 21 CFR 211.160General requirements4 of 7
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures3 of 7
- 21 CFR 211.188Batch production and control records3 of 7
- 21 CFR 211.22Responsibilities of quality control unit2 of 7
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 7
Show all 21
- 21 CFR 211.100Written procedures; deviations2 of 7
- 21 CFR 211.142Warehousing procedures2 of 7
- 21 CFR 211.170Reserve samples2 of 7
- 21 CFR 211.180General requirements2 of 7
- 21 CFR 211.25Personnel qualifications1 of 7
- 21 CFR 211.58Maintenance1 of 7
- 21 CFR 211.63Equipment design, size, and location1 of 7
- 21 CFR 211.87Retesting of approved components, drug product containers, and closures1 of 7
- 21 CFR 211.105Equipment identification1 of 7
- 21 CFR 211.122Materials examination and usage criteria1 of 7
- 21 CFR 211.182Equipment cleaning and use log1 of 7
- 21 CFR 211.194Laboratory records1 of 7
- 21 CFR 211.198Complaint files1 of 7
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, repacking
- Registration runs through
- Dec 31, 2026
- Registrant
- Continental Manufacturing Chemist, Inc.D-U-N-S 005278007
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1910648 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1910648. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.