Skip to content

Human cells and tissues (HCT/Ps) in FDA Form 483 observations

Establishments that recover, process and distribute human cells and tissues under 21 CFR Part 1271: donor eligibility, screening and testing, and processing controls. FDAgent finds 66 such observations in 21 Form 483s issued to 21 facilities, for inspections that ended between December 2024 and April 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
66
Each quoted below
Form 483s
21
Posted by FDA
Facilities
21
Distinct FEIs
Most recent
Apr 30, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 48 in 2025

Human cells and tissues observations in Form 483s by inspection year
YearObservations
20245
202548
202613

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR Part 1271

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“HCT/P*” · “donor eligibility” · “donor screening” · “donor testing” · “human cells” · “human tissue*” · “tissue bank*” · “tissue establishment*” · “tissue recover*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 66 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. NCFMC, a Medical CorporationInspection ended Aug 19, 2025 · FEI 3003971346 · Observation 1

    Donors were not determined to be ineligible that had risk factors or clinical evidence of communicable disease agents. Specifically, your firm did not determine ineligible known sperm donor (b) (4), (b) (6), (b) (7)(C) after he reported (b) (6), (b) (7)(C) (b) (6), (b) (7)(C) within the preceding five years. Your firm determined the donor to be eligible on 5/7/2021. Sperm was collected on (b) (6), (b) (7)(C) and transferred to a gestational …

    Opens with FDA's citation wording for 21 CFR 1271.75(d)Read the Form 483 →

  2. NCFMC, a Medical CorporationInspection ended Aug 19, 2025 · FEI 3003971346 · Observation 2

    Testing for communicable disease agents was not performed in accordance with the manufacturer's instructions. Your firm is not following the manufacturer's instructions for testing reproductive tissue donors for evidence of Chlamydia trachomatis and Neisseria gonorrhea. Specifically, 1. Your firm collects (b) (4) of urine rather than the required amount of between 20 mL to 30 mL. According to the manufacturer's instructions, collection of more …

    Opens with FDA's citation wording for 21 CFR 1271.80(c)Read the Form 483 →

  3. NCFMC, a Medical CorporationInspection ended Aug 19, 2025 · FEI 3003971346 · Observation 3

    Procedures were not designed to ensure compliance with the donor eligibility requirements. Your firm's written procedures have not been designed to ensure compliance with donor eligibility requirements. Specifically, 1. Your firm's written procedures do not always establish donor acceptance criteria for donors with identified risk factors. For example, your firm's procedures do not specify the criteria or timeframe for when donors will be …

    Opens with FDA's citation wording for 21 CFR 1271.47(a)Read the Form 483 →

  4. Elite Orthopedics, LLCInspection ended Jul 15, 2025 · FEI 3011803392 · Observation 1

    Procedures for core CTGP requirements were not available to personnel in the area where operations are performed, or in a nearby area when such availability is impractical. Specifically, On 07/15/2025, your firm was observed using an outdated procedure, titled, Human Tissue Product Distribution Guidance Manual - Version 1, Effective Date 2.1.16 to ensure the prevention, transmission, or spread of communicable diseases and disease agents during …

    Opens with FDA's citation wording for 21 CFR 1271.180(c)Read the Form 483 →

  5. Elite Orthopedics, LLCInspection ended Jul 15, 2025 · FEI 3011803392 · Observation 2

    Documentation of equipment maintenance, cleaning, sanitization, and calibration was not maintained. Specifically, Since 06/09/2023, your firm did not document pre-installation information, preventative maintenance, and control programming for the (b) (4) use to store (b) (4). As instructed in the (b) (4) Instructions User Manual for the following elements, • Unit requirements • As needed preventative maintenance, such as battery alarm check and …

    Opens with FDA's citation wording for 21 CFR 1271.200(e)Read the Form 483 →

  6. Elite Orthopedics, LLCInspection ended Jul 15, 2025 · FEI 3011803392 · Observation 3

    Storage temperatures of HCT/Ps were not recorded and maintained. Specifically, From (b) (4), your firm distributed (b) (4) tissue products and failed to record (b) (4) temperature of storage areas and perform a (b) (4) review of the (b) (4) Temperature Log. Also, did not maintained (b) (4) calibrations records for the (b) (4) thermometer.

    Opens with FDA's citation wording for 21 CFR 1271.260(e)Read the Form 483 →

  7. Elite Orthopedics, LLCInspection ended Jul 15, 2025 · FEI 3011803392 · Observation 4

    Records were not maintained concurrently with the performance of each step. Specifically, From 08/28/2018, your firm failed to document on the Tissue Tracking Log, as instructed in the procedure, titled, Human Tissue Product Distribution Guidance, Manual, Version 1.0, Effective 2.1.16. the following acceptance criteria of received tissue. • Label verification • Package Integrity, such as no tears, rips, or holes in packaging • Temperature …

    Opens with FDA's citation wording for 21 CFR 1271.270(a)Read the Form 483 →

  8. Elite Orthopedics, LLCInspection ended Jul 15, 2025 · FEI 3011803392 · Observation 5

    A records management system relating to core CGTP requirements was not followed. Specifically, Your firm failed to follow procedure, titled, Human Tissue Product Distribution Guidance Manual - Version 7, Effective Date 6.23.25 to document and maintain the following records relating to core Current Good Tissue Practices. • Packing List • Tissue Tracking Form • Incident Report Form • Corrective Action Request Form • Weekly Freezer Maintenance Form …

    Contains “human tissue*”Read the Form 483 →

  9. Conceive Fertility CenterInspection ended Jun 13, 2025 · FEI 3014721365 · Observation 1

    After the completion of the donor-eligibility determination, HCT/Ps were not accompanied with a statement whether the donor has been determined to be eligible or ineligible, based on the results of screening and testing. Specifically, (b) (4) out of (b) (4) directed semen donor eligibility records reviewed from 2022 to 2025 were determined ineligible. The (b) (4) directed semen donor eligibility records did not contain a statement with the reason …

    Opens with FDA's citation wording for 21 CFR 1271.55(a)(2)Read the Form 483 →

  10. Conceive Fertility CenterInspection ended Jun 13, 2025 · FEI 3014721365 · Observation 2

    The eligibility of an HCT/P donor was not determined and documented by a responsible person, based on results of donor screening and donor testing. Specifically, (b) (4) out of (b) (4) donor eligibility records reviewed from 2022 to 2025, the donor eligibility was performed by different nurse practitioners and physician assistants not by the Medical Director or a designated licensed physician. Your Standard Operating Procedure "Office Screening …

    Opens with FDA's citation wording for 21 CFR 1271.50(a)Read the Form 483 →

  11. Conceive Fertility CenterInspection ended Jun 13, 2025 · FEI 3014721365 · Observation 3

    A standard operating procedure for the release of HCT/Ps from donors that test reactive for cytomegalovirus (CMV) was not established, defined, documented and implemented. Specifically, Your Standard Operating Procedure "Office Screening of Patients Donating Human Cells (Oocytes and Sperm)" does not contain procedures describing donors whose specimens test reactive for cytomegalovirus (CMV) and how to interpret those CMV test results including …

    Opens with FDA's citation wording for 21 CFR 1271.85(b)(2)Read the Form 483 →

  12. Conceive Fertility CenterInspection ended Jun 13, 2025 · FEI 3014721365 · Observation 4

    You did not establish and maintain procedures for testing, screening and determining the eligibility of HCT/P donors. Specifically, Your Standard Operating Procedure "Office Screening of Patients Donating Human Cells (Oocytes and Sperm)" does not contain donor eligibility procedures describing requirements that must be met to determine a donor as eligible or ineligible. In addition, You do not have documented written or electronic procedures …

    Opens with FDA's citation wording for 21 CFR 1271.47(a)Read the Form 483 →

  13. Conceive Fertility CenterInspection ended Jun 13, 2025 · FEI 3014721365 · Observation 5

    Information on of donors of HCT/Ps were not in English and not accompanied by a statement of authenticity by the translator that specifically identifies the translated document. Specifically, the donor screening questionnaire for (b) (4) out of (b) (4) directed semen donor and (b) (4) out of (b) (4) directed oocyte donor records reviewed from the year 2022 to 2025 were not in (b) (4), translated to (b) (4), and not accompanied by a statement of …

    Contains “HCT/P*”Read the Form 483 →

  14. Performance Orthopedics Associates IncInspection ended Jun 13, 2025 · FEI 3014678321 · Observation 1

    Procedures appropriate to meet core CGTP requirements for all steps that you perform in the manufacture of HCT/Ps were not established. Specifically, 1. There is no established procedure or records that address receipt and distribution of HCT/Ps. 2. There is no established procedure or records that addresses facility cleaning and sanitation. 3. There is no evidence of review or approval of any SOP provided.

    Opens with FDA's citation wording for 21 CFR 1271.180(a)Read the Form 483 →

  15. Performance Orthopedics Associates IncInspection ended Jun 13, 2025 · FEI 3014678321 · Observation 2

    The quality program has not ensured that procedures exist for information relating to core CGTP requirements, including complaints. Specifically, 1. There is no established procedure or records addressing complaint handling. 2. There are no established procedures or records addressing investigation of HCT/P deviations relating to core CGTP requirements or adverse reactions.

    Contains “HCT/P*”Read the Form 483 →

  16. Performance Orthopedics Associates IncInspection ended Jun 13, 2025 · FEI 3014678321 · Observation 3

    Records were not retained for the appropriate length of time, at least 10 years after the date of a particular HCT/Ps distribution, disposition, or expiration, whichever is latest, when the date of administration is not known. Specifically, 1. The firm did not retain any records of HCT/Ps stored and/or distributed for at least 10 years after distribution, disposition, or expiration.

    Opens with FDA's citation wording for 21 CFR 1271.270(d)Read the Form 483 →

  17. Seattle Sperm BankInspection ended Jun 12, 2025 · FEI 3028170589 · Observation 1

    HCT/Ps from ineligible donors which were made available for limited use were not prominently labeled with the Biohazard legend and a statement warning of communicable disease risks. Specifically, your firm did not label all ineligible directed donors with the following warning statement, "WARNING: Advise recipient of communicable disease risks" and the biohazard legend when shipping the vials to your main storage facility. Since February 2024, …

    Opens with FDA's citation wording for 21 CFR 1271.65(b)(2)Read the Form 483 →

  18. Seattle Sperm BankInspection ended Jun 12, 2025 · FEI 3028170589 · Observation 2

    After completion of the donor-eligibility determination, HCT/Ps were not accompanied with the summary of the records used to make the donor-eligibility determination. Specifically, when shipping vials of donated semen from ineligible directed donors, your firm does not include a summary of record with the following documented information: 1. The reason for ineligibility. 2. A statement that the communicable disease testing was performed by a …

    Opens with FDA's citation wording for 21 CFR 1271.55(a)(3)Read the Form 483 →

  19. AVEM Labs LLCInspection ended May 21, 2025 · FEI 3017596057 · Observation 1

    Processes with results which could not be fully verified by inspection and tests, were not validated and approved according to established procedures. Specifically, your firm has not validated the manufacturing process for amniotic membrane (b) (4) derived from human amniotic membrane. Since January 2025, you have manufactured and distributed (b) (4) amniotic membrane (b) (4)

    Opens with FDA's citation wording for 21 CFR 1271.230(a)Read the Form 483 →

  20. AVEM Labs LLCInspection ended May 21, 2025 · FEI 3017596057 · Observation 2

    Labeling procedures did not include verification of label accuracy. Specifically, your quality assurance personnel are not reviewing and approving all appropriate finished product labels as they relate to the amniotic membrane (b) (4) of BioVair DL that are distributed as (b) (4) , and (b) (4) (b) (4).

    Opens with FDA's citation wording for 21 CFR 1271.250(b)Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

  • 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?In this theme's rule12
  • 21 CFR 1271.50How do I determine whether a donor is eligible?In this theme's rule9
  • 21 CFR 1271.47What procedures must I establish and maintain?In this theme's rule8
  • 21 CFR 1271.75How do I screen a donor?In this theme's rule6
  • 21 CFR 1271.270RecordsIn this theme's rule4
  • 21 CFR 1271.80What are the general requirements for donor testing?In this theme's rule3
  • 21 CFR 1271.85What donor testing is required for different types of cells and tissues?In this theme's rule3
  • 21 CFR 1271.65How do I store an HCT/P from a donor determined to be ineligible, and what uses of the HCT/P are not prohibited?In this theme's rule2
  • 21 CFR 1271.90Are there other exceptions and what labeling requirements apply?In this theme's rule2
  • 21 CFR 1271.180ProceduresIn this theme's rule2

Ask FDAgent about human cells and tissues in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.