21 CFR 1271.250: Labeling controls
FDA's inspection data lists 24 Form 483 citations of 21 CFR 1271.250 at 22 facilities, from January 2009 to May 2, 2024.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 24
- At 23 inspections
- Facilities cited
- 22
- Distinct FEIs
- Most recent citation
- May 2, 2024
- North American Science Associates, LLC
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 1271.250 from the Electronic Code of Federal Regulations.
§ 1271.250 Labeling controls.
(a) General. You must establish and maintain procedures to control the labeling of HCT/Ps. You must design these procedures to ensure proper HCT/P identification and to prevent mix-ups.
(b) Verification. Procedures must include verification of label accuracy, legibility, and integrity.
(c) Labeling requirements. Procedures must ensure that each HCT/P is labeled in accordance with all applicable labeling requirements, including those in §§ 1271.55, 1271.60, 1271.65, 1271.90, 1271.290, and 1271.370, and that each HCT/P made available for distribution is accompanied by documentation of the donor eligibility determination as required under § 1271.55.
21 CFR Part 1271: Human Cells, Tissues, and Cellular and Tissue-Based Products, Subpart DRead on eCFR
Citations by year
Form 483 citations of 21 CFR 1271.250 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 6 in 2009
| Year | Form 483 citations |
|---|---|
| 2009 | 6 |
| 2010 | 4 |
| 2011 | 2 |
| 2012 | 1 |
| 2013 | 2 |
| 2014 | 3 |
| 2015 | 1 |
| 2016 | 2 |
| 2018 | 1 |
| 2024 | 2 |
How FDA words this citation
FDA's short descriptions and citation text on these 24 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Controlling the labeling of HCT/Ps13 citations
- All labeling requirements met5 citations
- Verification of label accuracy, legibility, integrity3 citations
- Design of labeling procedures2 citations
- Documentation of donor eligibility1 citations
Citation text
- “Labeling procedures did not ensure that HCT/Ps are labeled in accordance with all labeling requirements.”5 citations
- “Procedures to control the labeling of HCT/Ps were not established.”5 citations
- “Labeling procedures did not include verification of label accuracy.”2 citations
- “Labeling procedures were not designed to ensure proper HCT/P identification and to prevent mix-ups.”2 citations
Show 2 more
- “Labeling procedures did not ensure that HCT/Ps made available for distribution are accompanied by documentation of the donor eligibility determination.”1 citations
- “Labeling procedures did not include verification of label accuracy, legibility, and integrity.”1 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 1271.250, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Lions Eye Bank of Delaware Valley, Inc.2016-03-30 · FEI 3000718080Controlling the labeling of HCT/Ps
Show 4 more
What the observations say
Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 1271.250 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 1 observation ties this way. The highlighted sentence is the matched wording.
AVEM Labs LLC2025-05-21 · Observation 2
Labeling procedures did not include verification of label accuracy. Specifically, your quality assurance personnel are not reviewing and approving all appropriate finished product labels as they relate to the amniotic membrane (b) (4) of BioVair DL that are distributed as (b) (4) , and (b) (4) (b) (4).
This observation opens with FDA's standard wording for 21 CFR 1271.250(b).
Often cited at the same inspection
Of the 23 inspections where FDA cited 21 CFR 1271.250, the share where it also cited each of these sections.
- 21 CFR 1271.160Establishment and maintenance of a quality program11 (48%)
- 21 CFR 1271.195Environmental control and monitoring10 (43%)
- 21 CFR 1271.200Equipment8 (35%)
- 21 CFR 1271.230Process validation8 (35%)
- 21 CFR 1271.210Supplies and reagents7 (30%)
- 21 CFR 1271.265Receipt, predistribution shipment, and distribution of an HCT/P7 (30%)
Ask FDAgent about 21 CFR 1271.250
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 1271.250; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.