21 CFR 1271.160: Establishment and maintenance of a quality program
FDA's inspection data lists 279 Form 483 citations of 21 CFR 1271.160 at 175 facilities, from December 2008 to August 22, 2025.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 279
- At 203 inspections
- Facilities cited
- 175
- Distinct FEIs
- Most recent citation
- Aug 22, 2025
- Dental Implant Technologies, Inc
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 1271.160 from the Electronic Code of Federal Regulations.
§ 1271.160 Establishment and maintenance of a quality program.
(a) General. If you are an establishment that performs any step in the manufacture of HCT/Ps, you must establish and maintain a quality program intended to prevent the introduction, transmission, or spread of communicable diseases through the manufacture and use of HCT/Ps. The quality program must be appropriate for the specific HCT/Ps manufactured and the manufacturing steps performed. The quality program must address all core CGTP requirements listed in § 1271.150(b).
(b) Functions. Functions of the quality program must include:
(1) Establishing and maintaining appropriate procedures relating to core CGTP requirements, and ensuring compliance with the requirements of § 1271.180 with respect to such procedures, including review, approval, and revision;
(2) Ensuring that procedures exist for receiving, investigating, evaluating, and documenting information relating to core CGTP requirements, including complaints, and for sharing any information pertaining to the possible contamination of the HCT/P or the potential for transmission of a communicable disease by the HCT/P with the following:
(i) Other establishments that are known to have recovered HCT/Ps from the same donor;
(ii) Other establishments that are known to have performed manufacturing steps with respect to the same HCT/P; and
(iii) Relating to consignees, in the case of such information received after the HCT/P is made available for distribution, shipped to the consignee, or administered to the recipient, procedures must include provisions for assessing risk and appropriate followup, and evaluating the effect this information has on the HCT/P and for the notification of all entities to whom the affected HCT/P was distributed, the quarantine and recall of the HCT/P, and/or reporting to FDA, as necessary.
(3) Ensuring that appropriate corrective actions relating to core CGTP requirements, including reaudits of deficiencies, are taken and documented, as necessary. You must verify corrective actions to ensure that such actions are effective and are in compliance with CGTP. Where appropriate, corrective actions must include both short-term action to address the immediate problem and long-term action to prevent the problem's recurrence. Documentation of corrective actions must include, where appropriate:
(i) Identification of the HCT/P affected and a description of its disposition;
(ii) The nature of the problem requiring corrective action;
(iii) A description of the corrective action taken; and
(iv) The date(s) of the corrective action.
(4) Ensuring the proper training and education of personnel involved in activities related to core CGTP requirements;
(5) Establishing and maintaining appropriate monitoring systems as necessary to comply with the requirements of this subpart (e.g., environmental monitoring);
(6) Investigating and documenting HCT/P deviations and trends of HCT/P deviations relating to core CGTP requirements and making reports if required under § 1271.350(b) or other applicable regulations. Each investigation must include a review and evaluation of the HCT/P deviation, the efforts made to determine the cause, and the implementation of corrective action(s) to address the HCT/P deviation and prevent recurrence.
(c) Audits. You must periodically perform for management review a quality audit, as defined in § 1271.3(gg), of activities related to core CGTP requirements.
(d) Computers. You must validate the performance of computer software for the intended use, and the performance of any changes to that software for the intended use, if you rely upon the software to comply with core CGTP requirements and if the software either is custom software or is commercially available software that has been customized or programmed (including software programmed to perform a user defined calculation or table) to perform a function related to core CGTP requirements. You must verify the performance of all other software for the intended use if you rely upon it to comply with core CGTP requirements. You must approve and document these activities and results before implementation.
21 CFR Part 1271: Human Cells, Tissues, and Cellular and Tissue-Based Products, Subpart DRead on eCFR
Citations by year
Form 483 citations of 21 CFR 1271.160 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 57 in 2009
| Year | Form 483 citations |
|---|---|
| 2008 | 3 |
| 2009 | 57 |
| 2010 | 36 |
| 2011 | 23 |
| 2012 | 40 |
| 2013 | 13 |
| 2014 | 13 |
| 2015 | 13 |
| 2016 | 12 |
| 2017 | 5 |
| 2018 | 3 |
| 2019 | 13 |
| 2020 | 1 |
| 2021 | 8 |
| 2022 | 7 |
| 2023 | 10 |
| 2024 | 13 |
| 2025 | 9 |
How FDA words this citation
FDA's short descriptions and citation text on these 279 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- All core requirements covered in program46 citations
- Deviations--evaluation, cause, corrective action35 citations
- Quality audits performed periodically33 citations
- Ensuring appropriate core requirements followed28 citations
- Deviations--Investigation, documenting, trending19 citations
Show 3 more
- Program is appropriate for the HCT/Ps19 citations
- Training of personnel16 citations
- Actions verified, short and long term solutions14 citations
Citation text
- “Periodic quality audits of activities related to core CGTP requirements have not been performed.”33 citations
- “Investigation of deviations related to core CGTP requirements did not include a review and evaluation of the deviation, efforts to determine the cause of the deviation and corrective action(s) to address the deviation and prevent recurrence.”17 citations
- “A quality program which addresses all of the core CGTP requirements, appropriate for the HCT/Ps manufactured and the manufacturing steps performed, has not been established.”16 citations
- “The quality program has not ensured the proper training and education of personnel involved in core GTP activities.”16 citations
Show 2 more
- “The quality program has not ensured that procedures exist for receiving, investigating, evaluating and documenting information relating to core CGTP requirements, including complaints.”10 citations
- “The quality program has not established and maintained appropriate monitoring systems.”10 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 1271.160, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Charlotte Mecklenburg Hospital Authority dba Lifeshare Carolinas2025-03-04 · FEI 3001237890Deviations--Investigation, documenting, trending
Show 4 more
- Eurofins Donor & Product Testing, Inc. Atlanta2024-11-05 · FEI 3012822744Actions verified, short and long term solutions
What the observations say
Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 1271.160 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 1 observation ties this way. The highlighted sentence is the matched wording.
Donor Services Laboratories Inc Tampa2025-09-12 · Observation 2
The quality program does not include the investigation and the documentation of HCT/P deviations relating to core CTGP requirements. Specifically, approximately 21 failed test runs from June 2024 to present were reviewed and 18 appeared to be lacking details specific to the investigation, outcome, and actions taken. For example: a) (b) (4) Failed Run Report dated 4/5/2025 documents that the cause of fail is (b) (4) (b) (4) b) (b) (4) Failed Run …
This observation opens with FDA's standard wording for 21 CFR 1271.160(b)(6).
Often cited at the same inspection
Of the 203 inspections where FDA cited 21 CFR 1271.160, the share where it also cited each of these sections.
- 21 CFR 1271.180Procedures71 (35%)
- 21 CFR 1271.200Equipment49 (24%)
- 21 CFR 1271.265Receipt, predistribution shipment, and distribution of an HCT/P49 (24%)
- 21 CFR 1271.270Records44 (22%)
- 21 CFR 1271.195Environmental control and monitoring39 (19%)
- 21 CFR 1271.260Storage37 (18%)
Ask FDAgent about 21 CFR 1271.160
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 1271.160; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.