21 CFR 1271.270: Records
FDA's inspection data lists 164 Form 483 citations of 21 CFR 1271.270 at 126 facilities, from October 2008 to August 15, 2025.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 164
- At 140 inspections
- Facilities cited
- 126
- Distinct FEIs
- Most recent citation
- Aug 15, 2025
- Solid MD Inc
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 1271.270 from the Electronic Code of Federal Regulations.
§ 1271.270 Records.
(a) General. You must maintain records concurrently with the performance of each step required in this subpart and subpart C of this part. Any requirement in this part that an action be documented involves the creation of a record, which is subject to the requirements of this section. All records must be accurate, indelible, and legible. The records must identify the person performing the work and the dates of the various entries, and must be as detailed as necessary to provide a complete history of the work performed and to relate the records to the particular HCT/P involved.
(b) Records management system. You must establish and maintain a records management system relating to core CGTP requirements. Under this system, records pertaining to a particular HCT/P must be maintained in such a way as to facilitate review of the HCT/Ps history before making it available for distribution and, if necessary, subsequent to the HCT/Ps release as part of a followup evaluation or investigation. Records pertinent to the manufacture of HCT/Ps (e.g., labeling and packaging procedures, and equipment logs) must also be maintained and organized under the records management system. If records are maintained in more than one location, then the records management system must be designed to ensure prompt identification, location, and retrieval of all records.
(c) Methods of retention. You may maintain records required under this subpart electronically, as original paper records, or as true copies such as photocopies, microfiche, or microfilm. Equipment that is necessary to make the records available and legible, such as computer and reader equipment, must be readily available. Records stored in electronic systems must be backed up.
(d) Length of retention. You must retain all records for 10 years after their creation, unless stated otherwise in this part. However, you must retain the records pertaining to a particular HCT/P at least 10 years after the date of its administration, or if the date of administration is not known, then at least 10 years after the date of the HCT/Ps distribution, disposition, or expiration, whichever is latest. You must retain records for archived specimens of dura mater for 10 years after the appropriate disposition of the specimens.
(e) Contracts and agreements. You must maintain the name and address and a list of the responsibilities of any establishment that performs a manufacturing step for you. This information must be available during an inspection conducted under § 1271.400.
21 CFR Part 1271: Human Cells, Tissues, and Cellular and Tissue-Based Products, Subpart DRead on eCFR
Citations by year
Form 483 citations of 21 CFR 1271.270 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 24 in 2009
| Year | Form 483 citations |
|---|---|
| 2008 | 2 |
| 2009 | 24 |
| 2010 | 12 |
| 2011 | 16 |
| 2012 | 12 |
| 2013 | 9 |
| 2014 | 5 |
| 2015 | 1 |
| 2016 | 4 |
| 2017 | 7 |
| 2018 | 6 |
| 2019 | 20 |
| 2021 | 5 |
| 2022 | 2 |
| 2023 | 15 |
| 2024 | 13 |
| 2025 | 11 |
How FDA words this citation
FDA's short descriptions and citation text on these 164 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Records incomplete60 citations
- Records maintained concurrently41 citations
- Accurate, indelible, legible27 citations
- Retention time (10 year rules)16 citations
- Management system re: core CGTPs7 citations
Show 3 more
- Contract firms--identities and responsibilities6 citations
- Prompt retrieval from multiple locations3 citations
- Back-up of electronic records2 citations
Citation text
- “Records were not maintained concurrently with the performance of each step.”41 citations
- “Records were not detailed as necessary to provide a complete history of work performed.”24 citations
- “Records were not retained for the appropriate length of time, 10 years after their creation.”12 citations
- “Records did not identify the person performing the work and were not detailed as necessary to provide a complete history of work performed.”11 citations
Show 2 more
- “Records were not accurate, indelible and legible.”11 citations
- “Records did not identify the person performing the work, did not show the dates of entries and were not detailed as necessary to provide a complete history of work performed.”9 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 1271.270, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Eurofins Donor & Product Testing, LLC, San Ramon2025-07-18 · FEI 3015136858Accurate, indelible, legible
Show 4 more
What the observations say
Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 1271.270 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 4 observations tie this way. The highlighted sentence is the matched wording.
Donor Services Laboratories Inc Tampa2025-09-12 · Observation 1
Records were not maintained concurrently with the performance of each step. Specifically, incubation times for the (b) (4) are not concurrently documented. On 9/9/2025, technologist (b) (6), (b) (7)(C) was observed recording the incubation stop time (b) (4) the (b) (4) of incubation. When questioned, the technologist stated that the time recorded represented the (b) (4) rather than the (b) (4) the plate (b) (4) from the incubator. A second …
This observation opens with FDA's standard wording for 21 CFR 1271.270(a).
Elite Orthopedics, LLC2025-07-15 · Observation 4
Records were not maintained concurrently with the performance of each step. Specifically, From 08/28/2018, your firm failed to document on the Tissue Tracking Log, as instructed in the procedure, titled, Human Tissue Product Distribution Guidance, Manual, Version 1.0, Effective 2.1.16. the following acceptance criteria of received tissue. • Label verification • Package Integrity, such as no tears, rips, or holes in packaging • Temperature …
This observation opens with FDA's standard wording for 21 CFR 1271.270(a).
Performance Orthopedics Associates Inc2025-06-13 · Observation 3
Records were not retained for the appropriate length of time, at least 10 years after the date of a particular HCT/Ps distribution, disposition, or expiration, whichever is latest, when the date of administration is not known. Specifically, 1. The firm did not retain any records of HCT/Ps stored and/or distributed for at least 10 years after distribution, disposition, or expiration.
This observation opens with FDA's standard wording for 21 CFR 1271.270(d).
Often cited at the same inspection
Of the 140 inspections where FDA cited 21 CFR 1271.270, the share where it also cited each of these sections.
- 21 CFR 1271.180Procedures48 (34%)
- 21 CFR 1271.160Establishment and maintenance of a quality program44 (31%)
- 21 CFR 1271.200Equipment32 (23%)
- 21 CFR 1271.265Receipt, predistribution shipment, and distribution of an HCT/P32 (23%)
- 21 CFR 1271.260Storage30 (21%)
- 21 CFR 1271.195Environmental control and monitoring25 (18%)
Ask FDAgent about 21 CFR 1271.270
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 1271.270; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.