Skip to content

Osteolife Biomedical I LLC

1951 Nw 7th Ave Sanibel Suite, Miami, Florida, United States

FEI 3014623896

FDA has 3 inspections on file for Osteolife Biomedical I LLC in Miami, Florida (FEI 3014623896), from 2018 to 2023. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published one citation from this inspection, under 21 CFR Part 1271, the rules for human cell and tissue products. It is listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483, and one more for the 483 from a later inspection, ending Feb 13, 2026, that FDA's Data Dashboard doesn't list yet.

FDA issued a warning letter on (CBER · Office of Biological Products Operations - Division I). No court action or import refusal is filed under this FEI.

One regulation was cited at more than one inspection: 21 CFR 1271.230(a).

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2018–2023
0 OAI · 2 VAI · 1 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
3 requests, latest FY2023
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Validation & approval--established procedures

      Processes with results which could not be fully verified by inspection and tests, were not validated and approved according to established procedures.

  2. NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic Products8 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Program is appropriate for the HCT/Ps

      A quality program appropriate for the HCT/Ps manufactured and manufacturing steps performed has not been defined and implemented.

    2. Causing contamination, increasing risks

      HCT/Ps were not processed in a way that does not cause contamination or cross contamination during processing.

    3. Design appropriate, suitably located

      Equipment used in the manufacture of HCT/Ps was not of appropriate design for its use.

    4. Evaluation--microorganisms, damage

      Incoming HCT/Ps were not evaluated for the presence and significance of microorganisms.

    5. Improperly released for distribution

      HCT/Ps that were determined to not meet release criteria designed to prevent communicable disease transmission were made available for distribution.

    Show 3 more citations
    1. Deviations--evaluation, cause, corrective action

      Investigation of deviations related to core CGTP requirements did not include a review and evaluation of the deviation, efforts to determine the cause of the deviation and corrective action(s) to address the deviation and prevent recurrence.

    2. Validation & approval--established procedures

      Processes with results which could not be fully verified by inspection and tests, were not validated and approved according to established procedures.

    3. Monitoring--cross contamination, exposure to CD

      Environmental conditions are not monitored when such conditions could cause contamination or cross contamination of HCT/Ps or equipment.

  3. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Verification elements

      Documentation of the verification of reagents did not include a certificate of analysis from the vendor.

    2. Procedures inadequate

      Procedures for the cleaning, sanitizing and maintenance of equipment were not established, maintained, defined and documented.

    3. Validation & approval--established procedures

      Processes with results which could not be fully verified by inspection and tests, were not validated and approved according to established procedures.

    4. Release criteria verified, documented

      Release criteria were not documented to have been met through a review of manufacturing and tracking records before HCT/Ps were made available for distribution.

    5. Controlling the labeling of HCT/Ps

      Procedures to control the labeling of HCT/Ps were not established, defined, documented and implemented.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending Feb 13, 2026

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on May 22, 2026. FDAgent holds no copy that FDA posted.

    1. Apr 16, 2026FDA-FOIA-2026-3867Form 483· 1 of 5 sitesRecords released
  • Inspection ending Feb 14, 2023VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-4201Form 483Closed
  • Inspection ending Feb 4, 2022NAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-4519Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3014623896 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3014623896. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.