21 CFR 1271.90: Are there other exceptions and what labeling requirements apply?

FDA's inspection data lists 105 Form 483 citations of 21 CFR 1271.90 at 85 facilities, from May 2009 to May 15, 2025.

Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.

Form 483 citations
105
At 101 inspections
Facilities cited
85
Distinct FEIs
Most recent citation
May 15, 2025
Ohio Fertility Providers LLC
Warning letters
0
State a violation of it

The regulation

The current text of 21 CFR 1271.90 from the Electronic Code of Federal Regulations.

§ 1271.90 Are there other exceptions and what labeling requirements apply?

(a) Donor-eligibility determination not required. You are not required to make a donor-eligibility determination under § 1271.50 or to perform donor screening or testing under §§ 1271.75, 1271.80 and 1271.85 for:

(1) Cells and tissues for autologous use; or

(2) Reproductive cells or tissue donated by a sexually intimate partner of the recipient for reproductive use; or

(3) Cryopreserved cells or tissue for reproductive use, other than embryos, originally excepted under paragraphs (a)(1) or (a)(2) of this section at the time of donation, that are subsequently intended for directed donation, provided that:

(i) Additional donations are unavailable, for example, due to the infertility or health of a donor of the cryopreserved reproductive cells or tissue; and

(ii) Appropriate measures are taken to screen and test the donor(s) before transfer to the recipient.

(4) A cryopreserved embryo, originally excepted under paragraph (a)(2) of this section at the time of recovery or cryopreservation, that is subsequently intended for directed or anonymous donation. When possible, appropriate measures should be taken to screen and test the semen and oocyte donors before transfer of the embryo to the recipient.

(b) Exceptions for reproductive use. An embryo originally intended for reproductive use for a specific individual or couple that is subsequently intended for directed or anonymous donation for reproductive use is excepted from the prohibition on use under § 1271.45(c) even when the applicable donor eligibility requirements under subpart C of this part are not met. Nothing in this paragraph creates an exception for deficiencies that occurred in making the donor eligibility determination for either the oocyte donor or the semen donor as required under § 1271.45(b), or for deficiencies in performing donor screening or testing, as required under §§ 1271.75, 1271.80, and 1271.85.

(c) Required labeling. As applicable, you must prominently label an HCT/P described in paragraphs (a) and (b) of this section as follows:

(1) “FOR AUTOLOGOUS USE ONLY,” if it is stored for autologous use.

(2) “NOT EVALUATED FOR INFECTIOUS SUBSTANCES,” unless you have performed all otherwise applicable screening and testing under §§ 1271.75, 1271.80, and 1271.85. This paragraph does not apply to reproductive cells or tissue labeled in accordance with paragraph (c)(6) of this section.

(3) Unless the HCT/P is for autologous use only, “WARNING: Advise recipient of communicable disease risks,”

(i) When the donor-eligibility determination under § 1271.50(a) is not performed or is not completed; or

(ii) If the results of any screening or testing performed indicate:

(A) The presence of relevant communicable disease agents and/or

(B) Risk factors for or clinical evidence of relevant communicable disease agents or diseases.

(4) With the Biohazard legend shown in § 1271.3(h), if the results of any screening or testing performed indicate:

(i) The presence of relevant communicable disease agents and/or

(ii) Risk factors for or clinical evidence of relevant communicable disease agents or diseases.

(5) “WARNING: Reactive test results for (name of disease agent or disease),” in the case of reactive test results.

(6) “Advise recipient that screening and testing of the donor(s) were not performed at the time of recovery or cryopreservation of the reproductive cells or tissue, but have been performed subsequently,” for paragraphs (a)(3) or (a)(4) of this section.

21 CFR Part 1271: Human Cells, Tissues, and Cellular and Tissue-Based Products, Subpart CRead on eCFR

Citations by year

Form 483 citations of 21 CFR 1271.90 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).

Peak: 13 in 2023

Form 483 citations of 21 CFR 1271.90 by inspection year
YearForm 483 citations
20091
20106
20116
20125
201312
20147
20157
20165
20171
20185
20199
20204
20219
20225
202313
20246
20254

How FDA words this citation

FDA's short descriptions and citation text on these 105 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.

Short descriptions

  • Eligibility not required--warning labels92 citations
  • Autologous use only--labeling13 citations

Citation text

  • “HCT/Ps for which the donor eligibility determination was not performed were not prominently labeled with the appropriate warning statements.”53 citations
  • “HCT/Ps for which the applicable donor eligibility requirements were not met were not prominently labeled with the appropriate warning statements.”25 citations
  • “HCT/Ps for autologous use and for which the donor eligibility determination was not performed were not labeled for autologous use only.”13 citations
  • “HCT/Ps for which the donor eligibility determination was not required were not prominently labeled with the appropriate warning statements.”11 citations
Show 1 more
  • “HCT/Ps for which the donor eligibility determination was not required and applicable donor eligibility requirements were not met were not prominently labeled with the appropriate warning statements.”3 citations

Facilities cited most recently

The latest inspections where FDA cited 21 CFR 1271.90, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.

Show 4 more

What the observations say

Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 1271.90 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 2 observations tie this way. The highlighted sentence is the matched wording.

  • Fort Worth Fertility P.A.2025-04-24 · Observation 4

    HCT/Ps for which the donor eligibility determination was not required and applicable donor eligibility requirements were not met were not prominently labeled with the appropriate warning statements. Specifically, Labeling for subsequently donated reproductive HCT/Ps does not contain the following warning statements: -"NOT EVALUATED FOR INFECTIOUS SUBSTANCES." -"WARNING: Advise patient of communicable disease risks." Recipient (b) (6), (b) (7) …

    This observation opens with FDA's standard wording for 21 CFR 1271.90(c).

  • Lin, James P MD Inc. d.b.a. Reproductive Fertility Center2025-03-12 · Observation 2

    HCT/Ps for which the donor eligibility determination was not required were not prominently labeled with the appropriate warning statements. Specifically, a) Review of records for directed oocyte and semen donors from found that HCT/Ps were not labeled with a statement advising recipient that screening and testing of the donor(s) . For example, Directed Donor, (Oocytes) Tissue Donation Date Donor Eligibility, Date 09/28/2022 Donor Testing Date …

    This observation opens with FDA's standard wording for 21 CFR 1271.90(c).

Often cited at the same inspection

Of the 101 inspections where FDA cited 21 CFR 1271.90, the share where it also cited each of these sections.

  • 21 CFR 1271.50How do I determine whether a donor is eligible?42 (42%)
  • 21 CFR 1271.47What procedures must I establish and maintain?38 (38%)
  • 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?37 (37%)
  • 21 CFR 1271.75How do I screen a donor?37 (37%)
  • 21 CFR 1271.60What quarantine and other requirements apply before the donor-eligibility determination is complete?15 (15%)
  • 21 CFR 1271.65How do I store an HCT/P from a donor determined to be ineligible, and what uses of the HCT/P are not prohibited?15 (15%)

Ask FDAgent about 21 CFR 1271.90

FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
  • Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
  • A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 1271.90; FDAgent quotes that sentence exactly.