FDA issued this Form 483 to Performance Orthopedics Associates Inc in Mountain Brk, Alabama (FEI 3014678321) at the end of a biologics inspection that ended June 13, 2025. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 26, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jun 13, 2025
Biologics · Human Cellular, Tissue, and Gene Therapies
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 26, 2026
500 days after the inspection
Facility
FEI 3014678321
Mountain Brk, Alabama

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Missing core CGTP procedures

    Procedures appropriate to meet core CGTP requirements for all steps that you perform in the manufacture of HCT/Ps were not established. Specifically, 1. There is no established procedure or records that address receipt and distribution of HCT/Ps. 2. There is no established procedure or records that addresses facility cleaning and sanitation. 3. There is no evidence of review or approval of any SOP provided.

  2. 2

    Quality program lacking complaint procedures

    The quality program has not ensured that procedures exist for information relating to core CGTP requirements, including complaints. Specifically, 1. There is no established procedure or records addressing complaint handling. 2. There are no established procedures or records addressing investigation of HCT/P deviations relating to core CGTP requirements or adverse reactions.

  3. 3

    Records not retained for 10 years

    Records were not retained for the appropriate length of time, at least 10 years after the date of a particular HCT/Ps distribution, disposition, or expiration, whichever is latest, when the date of administration is not known. Specifically, 1. The firm did not retain any records of HCT/Ps stored and/or distributed for at least 10 years after distribution, disposition, or expiration.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.