Verde Cosmetic Labs, LLC
19845 Nordhoff St, Northridge, California, United States
FEI 3014015976
FDA has 2 inspections on file for Verde Cosmetic Labs, LLC in Northridge, California (FEI 3014015976), from 2021 to 2023. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two of the four FOIA requests for this site have asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations IV). No court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.100(a) and 21 CFR 211.22(d).
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2021–2023
- 2 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 4 requests, latest FY2023
- Warning letters
- · CDER · Division of Pharmaceutical Quality Operations IV ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and followed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance20 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls and returned or salvaged drug products.
No written record of investigation
Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
Specific information required in individual logs
Individual equipment logs do not show date, product and lot number of each batch processed.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Show 15 more citations
Personnel dating/signing equipment log
The persons double-checking the cleaning and maintenance are not dating and signing or initialing the equipment cleaning and use log.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Calibration/Inspection/Checking not done
Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices.
Mfg / Processing Operations Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure.
Sampling and testing plans not followed
Written procedures for sampling and testing plans are not followed for each drug product.
Component addition checked by 2nd person
Each component is not added to a batch by one person and verified by a second person.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing of the drug product.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.
Inspection ending Feb 9, 2023OAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2023-4151Form 483Closed
- Jul 30, 2024FDA-FOIA-2024-6641Form 483Closed
Inspection ending Oct 15, 2021OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 30, 2024FDA-FOIA-2024-6642Form 483Closed
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Aug 25, 2022FDA-FOIA-2022-6184Form 483· 1 of 2 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 17 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.100Written procedures; deviations2 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.63Equipment design, size, and location1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
- 21 CFR 211.101Charge-in of components1 of 2
Show all 17
- 21 CFR 211.103Calculation of yield1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.180General requirements1 of 2
- 21 CFR 211.182Equipment cleaning and use log1 of 2
- 21 CFR 211.186Master production and control records1 of 2
- 21 CFR 211.192Production record review1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Division of Pharmaceutical Quality Operations IV · DrugsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014015976 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014015976. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.