Skip to content

Multaler Et Cie S.A.S.

Zone Industrielle, 1 rue Ambroise Croizat, Argenteuil, France

FEI 3010165406

FDA has 2 inspections on file for Multaler Et Cie S.A.S. in Argenteuil, France (FEI 3010165406), from 2017 to 2024. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2017–2024
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    2. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    3. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

    4. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    5. Calibration/Inspection/Checking not done

      Routine checking of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.

    Show 2 more citations
    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Description of containers, labels, et. al.

      Master production and control records lack a specimen or copy of each label and all other labeling.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance11 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

    2. Suitability of testing methods verified

      The suitability of all testing methods is not verified under actual conditions of use.

    3. Procedures Written and Followed

      Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written.

    4. Lack of quality control unit

      There is no quality control unit.

    5. Calibration - at intervals, written program, remedial action

      The calibration of instruments is not done at suitable intervals with provisions for remedial action in the event accuracy and/or precision limits are not met.

    Show 6 more citations
    1. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    3. SOPs not followed / documented

      Written production and process control procedures are not documented at the time of performance.

    4. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not followed.

    5. Samples (various types) representative, identified properly

      Samples taken to determine conformance to appropriate written specifications for the acceptance of each lot within each shipment of components and drug product containers are not representative and adequately identified.

    6. Batch production and Batch Control Record Requirements

      The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing.

Regulations FDA cited here

The 14 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.

Show all 14

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010165406 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010165406. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.