Skip to content

B & J Group

1001 New Mill Ford Road, Morrisville, Pennsylvania, United States

FEI 3010096700

FDA has 3 inspections on file for B & J Group in Morrisville, Pennsylvania (FEI 3010096700), from 2016 to 2023. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations I). No court action or import refusal is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2016–2023
0 OAI · 3 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
2 requests, latest Sep 9, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    2. Calibration - at intervals, written program, remedial action

      The calibration of instruments is not done at suitable intervals in accordance with an established written program.

    3. Active ingredient retained sample kept

      A sample which is representative of each lot in each shipment of each active ingredient is not retained.

    4. Identification of Persons Performing Significant Steps

      The batch production and control records are deficient in that they do not include identification of persons each significant step in the operation.

    5. Component identification test

      Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.

    Show 1 more citation
    1. Personnel dating/signing equipment log

      The persons performing the cleaning and maintenance are not dating and signing or initialing the equipment cleaning and use log.

  2. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices15 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

    2. Accurate reproduction

      The batch production and control records are deficient in that they are not checked for accuracy, dated, and signed.

    3. Components withheld from use pending release

      Each lot of components is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.

    4. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    5. Test methods

      The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.

    Show 10 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    2. Actual vs. theoretical yields not determined

      Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing and packaging of the drug product.

    3. GMP Training Frequency

      GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.

    4. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    5. Examinations documented

      The results of the examination of the packaged and labeled products were not documented in the batch production or control records.

    6. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

    7. Quality control unit review of records

      Drug product production and control records, are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

    8. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    9. Reserve drug product sample quantity - all tests

      The reserve sample of drug product does not consist of at least twice the quantity necessary to perform all the required tests of drug product.

    10. Records not made readily available to FDA

      Records associated with drug product components, containers, closures, labeling, production, control and distribution and within the retention period for such records, were not made readily available for authorized inspection.

  3. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices16 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Handling and Storage to Prevent Contamination

      There was a failure to handle and store components at all times in a manner to prevent contamination.

    2. Changes to Procedures Not Reviewed, Approved

      Changes to written procedures are not reviewed and approved by the quality control unit.

    3. Batch production and Batch Control Record Requirements

      The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing and packing.

    4. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    5. Cleaning/maintenance records not kept

      Records are not kept for the maintenance, cleaning and inspection of equipment.

    Show 11 more citations
    1. Subdivided component container identification

      Containers holding subdivided components for drug product manufacturing are deficiently identified in that they lack the component name and item code.

    2. Acceptance criteria for sampling & testing

      Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet as a condition for their approval and release.

    3. Identification of persons involved, each significant step

      Batch production and control records do not include the identification of the persons performing, directly supervising and checking each significant step in the operation, for each batch of drug product produced.

    4. Signature and checking of records -- 2 persons

      The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.

    5. Dates not included for each significant step

      Batch production and control records do not include dates of each significant step in the manufacture of the batch for each batch of drug product produced.

    6. Calibration/Inspection/Checking not done

      Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance.

    7. Identification of each component or in-process material

      Batch production and control records do not include the specific identification of each batch of component used for each batch of drug product produced.

    8. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    9. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    10. Prevention of contamination

      Your facilities are not adequate to ensure the prevention of contamination of product by substances and environmental conditions that could reasonably be expected to have an adverse effect on product quality.

    11. Rejecting When Specifications Not Met

      Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Sep 9, 2025. Each one asked for a Form 483.

  • Inspection ending Oct 2, 2023VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jan 2, 2024FDA-FOIA-2024-22Form 483Closed
  • Inspection ending Feb 9, 2022

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Sep 9, 2025FDA-FOIA-2025-10757Form 483No records found

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 22 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.

Show all 22

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010096700 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010096700. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.