Skip to content

Sun Pharmaceutical Industries, Inc.

29 Dunham Rd, Billerica, Massachusetts, United States

FEI 3009395771DUNS 037074409

Company: Sun Pharmaceutical Industries, Inc. · Linked by exact D-U-N-S match (146974886) in FDA registration data

FDA has 14 inspections on file for Sun Pharmaceutical Industries, Inc. in Billerica, Massachusetts (FEI 3009395771), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 9 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three FOIA requests have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Seven regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Sun Pharmaceutical Industries, Inc. (D-U-N-S 146974886), has registered 1 other site.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
14, 2009–2025
0 OAI · 11 VAI · 3 NAI
Inspections with 483 observations shown
6 of 14
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
3 requests, latest May 18, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

14 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Defined areas of adequate size for operations

      The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    3. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

    4. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    5. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    Show 4 more citations
    1. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing and holding of a drug product are not maintained in a good state of repair.

    2. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

    3. Label storage access limited to authorized personnel

      Access to the storage area for labels and labeling materials is not limited to authorized personnel.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Components withheld from use pending release

      Each lot of components is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.

    2. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    3. Contamination, chemical or physical change, deterioration

      An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Training , Education , Experience overall

      Employees engaged in the processing of a drug product lack the training required to perform their assigned functions.

    2. Calibration/Inspection/Checking not done

      Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance.

    3. Extent of discrepancy, failure investigations

      Investigations of an unexplained discrepancy did not extend to other drug products that may have been associated with the specific failure or discrepancy.

    4. Test methods

      The accuracy and specificity of test methods have not been documented.

    5. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    Show 1 more citation
    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

  10. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  11. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    2. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    3. Actual yield, % of theoretical yield

      The batch production and control records do not include a statement of the percentage of theoretical yield at appropriate stages of processing for each batch of drug product produced.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    5. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    Show 1 more citation
    1. Individual inventory record

      Records fail to include an individual inventory record of each reconciliation of the use of each component with sufficient information to allow determination of any associated batch or lot of drug product.

  12. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  13. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed.

    2. Defined areas of adequate size for operations

      The control systems necessary to prevent contamination or mix-ups are deficient.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    4. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not justified.

    5. Reactive/Additive/Absorptive Containers/Closures

      Drug product containers or closures are reactive and additive so as to alter the safety, identity, strength, quality, and purity of the drug beyond the official or established requirements.

    Show 4 more citations
    1. Calibration/Inspection/Checking not done

      Routine inspection and checking of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.

    2. Contamination, chemical or physical change, deterioration

      An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.

    3. Following/documenting laboratory controls

      Established standards and test procedures are not followed and documented at the time of performance.

    4. Examination on receipt, before acceptance

      Each container or grouping of containers of components is not examined visually upon receipt and before acceptance for appropriate labeling as to contents.

  14. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on May 18, 2026. Each one asked for a Form 483.

  • Inspection ending Apr 18, 2025VAI

    3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 22, 2025. FDAgent holds no copy that FDA posted.

    1. May 18, 2026FDA-FOIA-2026-5063Form 483· 1 of 5 sitesWithdrawn
    2. Jul 7, 2025FDA-FOIA-2025-8298Form 483· 1 of 4 sitesRecords released
    3. May 16, 2025FDA-FOIA-2025-4498Form 483· 1 of 8 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 22 sections of 21 CFR in FDA’s published citations for 6 of this facility’s 14 inspections, with how many of them cited each.

Show all 22

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Sun Pharmaceutical Industries, Inc.D-U-N-S 146974886

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Sun Pharmaceutical Industries, Inc. (D-U-N-S 146974886) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • Ohm Laboratories Inc.New Brunswick, New Jersey · FEI 300413205822 inspections22latestOct 31, 2024NAINone on file

Other FEIs recorded as Sun Pharmaceutical Industries, Inc.

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3009395771 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3009395771. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.