Raf LLC
200 Pate Dr, Greenville, South Carolina, United States
FEI 3006795778
FDA has 3 inspections on file for Raf LLC in Greenville, South Carolina (FEI 3006795778), from 2008 to 2016. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2008–2016
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Examination of packaging and labeling
Examination of packaging and labeling materials for suitability and correctness before packaging operations is not performed and not documented in the batch production records .
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established .
Cleaning SOPs/instructions
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
Calibration - at intervals, written program, remedial action
The calibration of instruments , apparatus , gauges and recording devices is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met .
Show 7 more citations
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed .
Acceptance of in-process materials
Determinations of conformance to appropriate written specifications for acceptance are deficient for in-process materials.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals .
Potable water standards not met
The potable water being permitted for use in the potable water system fails to meet standards prescribed by the Environmental Protection Agency.
Description of containers and closures
Batch production and control records do not include a description of drug product containers and closures used for each batch of drug product produced.
Top/Middle/Bottom container sampling
Sampling procedures are deficient regarding sampling components from the top, middle, and bottom of container.
Written records kept in individual logs
Written records of major equipment cleaning , maintenance and use are not included in individual equipment logs.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance22 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Approval and review of procedures
Written procedures are not drafted, reviewed and approved by the appropriate organizational units and reviewed and approved by the quality control unit.
Sampling and testing plans not described
Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.
Calibration/Inspection/Checking not done
Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.
Sample identification and other information
Laboratory records do not include a description of the sample received for testing, the quantity of the sample, the lot number or other distinctive code of the sample, the date the sample was taken, and the date the sample was received for testing.
Statement of methods and data
Laboratory records do not include a statement of each method used in the testing of a sample.
Show 17 more citations
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include assignment of responsibility, description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance, and instructions for protection of clean equipment from contamination prior to use.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Lab controls established, including changes
The establishment of specifications, sampling plans, and test procedures including any changes thereto, are not reviewed and approved by the quality control unit.
In-process materials - sampling, testing procedures
Laboratory controls do not include a description of testing procedures for in-process materials.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Written in-process control procedures
Written procedures are not established that describe the in-process controls, tests, and examinations to be conducted on appropriate samples of in-process materials of each batch.
Laboratory equipment calibration records
Laboratory records do not include complete records of the periodic calibration of laboratory instruments.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Status of Each Lot Identified
Each lot of components, drug product containers, and closures was not appropriately identified as to its status in terms of being quarantined, approved or rejected.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.
Calibration - at intervals, written program, remedial action
The calibration of instruments and apparatus is not done at suitable intervals in accordance with an established written program.
Description of containers and closures
Batch production and control records do not include a description of drug product containers and closures used for each batch of drug product produced.
Records of any sampling performed
Batch production and control records do not include a record of any sampling performed, for each batch of drug product produced.
Distinctive ID or code not recorded in batch record
The batch records do not record the distinctive identification number, code, and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
Identity of major equipment and lines used
Batch production and control records do not include the identity of individual major equipment used for each batch of drug product produced.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing, and packaging of the drug product.
Regulations FDA cited here
The 18 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.67Equipment cleaning and maintenance2 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 2
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.188Batch production and control records2 of 2
- 21 CFR 211.48Plumbing1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
- 21 CFR 211.80General requirements1 of 2
Show all 18
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.103Calculation of yield1 of 2
- 21 CFR 211.105Equipment identification1 of 2
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 2
- 21 CFR 211.111Time limitations on production1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.130Packaging and labeling operations1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.182Equipment cleaning and use log1 of 2
- 21 CFR 211.194Laboratory records1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006795778 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006795778. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.