FDA has 3 inspections on file for Raf LLC in Greenville, South Carolina (FEI 3006795778), from 2008 to 2016. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Five regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2008–2016
0 OAI · 3 VAI · 0 NAI
Inspections with 483 observations shown
2 of 3
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Examination of packaging and labeling

      Examination of packaging and labeling materials for suitability and correctness before packaging operations is not performed and not documented in the batch production records .

    2. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    3. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established .

    4. Cleaning SOPs/instructions

      Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.

    5. Calibration - at intervals, written program, remedial action

      The calibration of instruments , apparatus , gauges and recording devices is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met .

    Show 7 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed .

    2. Acceptance of in-process materials

      Determinations of conformance to appropriate written specifications for acceptance are deficient for in-process materials.

    3. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals .

    4. Potable water standards not met

      The potable water being permitted for use in the potable water system fails to meet standards prescribed by the Environmental Protection Agency.

    5. Description of containers and closures

      Batch production and control records do not include a description of drug product containers and closures used for each batch of drug product produced.

    6. Top/Middle/Bottom container sampling

      Sampling procedures are deficient regarding sampling components from the top, middle, and bottom of container.

    7. Written records kept in individual logs

      Written records of major equipment cleaning , maintenance and use are not included in individual equipment logs.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance22 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Approval and review of procedures

      Written procedures are not drafted, reviewed and approved by the appropriate organizational units and reviewed and approved by the quality control unit.

    2. Sampling and testing plans not described

      Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.

    3. Calibration/Inspection/Checking not done

      Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.

    4. Sample identification and other information

      Laboratory records do not include a description of the sample received for testing, the quantity of the sample, the lot number or other distinctive code of the sample, the date the sample was taken, and the date the sample was received for testing.

    5. Statement of methods and data

      Laboratory records do not include a statement of each method used in the testing of a sample.

    Show 17 more citations
    1. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component.

    2. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include assignment of responsibility, description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance, and instructions for protection of clean equipment from contamination prior to use.

    3. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    4. Lab controls established, including changes

      The establishment of specifications, sampling plans, and test procedures including any changes thereto, are not reviewed and approved by the quality control unit.

    5. In-process materials - sampling, testing procedures

      Laboratory controls do not include a description of testing procedures for in-process materials.

    6. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    7. Written in-process control procedures

      Written procedures are not established that describe the in-process controls, tests, and examinations to be conducted on appropriate samples of in-process materials of each batch.

    8. Laboratory equipment calibration records

      Laboratory records do not include complete records of the periodic calibration of laboratory instruments.

    9. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components conform to appropriate standards of identity, strength, quality and purity.

    10. Status of Each Lot Identified

      Each lot of components, drug product containers, and closures was not appropriately identified as to its status in terms of being quarantined, approved or rejected.

    11. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.

    12. Calibration - at intervals, written program, remedial action

      The calibration of instruments and apparatus is not done at suitable intervals in accordance with an established written program.

    13. Description of containers and closures

      Batch production and control records do not include a description of drug product containers and closures used for each batch of drug product produced.

    14. Records of any sampling performed

      Batch production and control records do not include a record of any sampling performed, for each batch of drug product produced.

    15. Distinctive ID or code not recorded in batch record

      The batch records do not record the distinctive identification number, code, and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.

    16. Identity of major equipment and lines used

      Batch production and control records do not include the identity of individual major equipment used for each batch of drug product produced.

    17. Actual vs. theoretical yields not determined

      Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing, and packaging of the drug product.

Regulations FDA cited here

The 18 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

Show all 18

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006795778 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006795778. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.