Skip to content

Regenerative Sciences, LLC

403 Summit Blvd Unit 201, Broomfield, Colorado, United States

FEI 3006039994

FDA has 2 inspections on file for Regenerative Sciences, LLC in Broomfield, Colorado (FEI 3006039994), from 2009 to 2010. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 28 citations from this inspection: 27 under 21 CFR Part 211, the manufacturing rules for finished drugs, and 1 under 21 CFR Part 600, the general rules for biological products. They are listed below.

FDA's compliance record also lists one other action under this FEI: Injunction, . No warning letter or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2009–2010
2 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies28 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning/maintenance records not kept

      Records are not kept for the cleaning and sanitizing of equipment.

    2. Written Procedures Not Followed

      Written procedures are not followed for the receipt and handling of components.

    3. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    4. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed. Electronic records are used, but they do not meet systems validation requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components, drug product containers, closures, in-process materials, and drug products conform to appropriate standards of identity, strength, quality and purity.

    Show 23 more citations
    1. Mfg / Processing Operations Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.

    2. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    3. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    4. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    5. Sterile & pyrogen free

      There is no assurance that final containers and closures for products intended for use by injection are sterile and pyrogen free.

    6. Floors, walls, ceiling surfaces

      Aseptic processing areas are deficient in that floors, walls, and ceilings are not smooth and/or hard surfaces that are easily cleanable.

    7. Lack of quality control unit

      There is no quality control unit.

    8. Air Supply

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

    9. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

    10. Air filtration system lacking in production area

      The production area air supply lacks an appropriate air filtration system.

    11. Components withheld from use pending release

      Each lot of components, drug product containers, and closures is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.

    12. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not justified.

    13. No written record of investigation

      Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.

    14. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    15. Temperature / Humidity Controls

      Aseptic processing areas are deficient regarding humidity controls.

    16. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    17. Manufacturing Instructions and Specifications

      The master production and control records are deficient in that they do not include complete instructions.

    18. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    19. Reprocessing procedures lack steps to be taken

      Reprocessing procedures lack the steps to be taken to insure that reprocessed batches will conform with all established standards, specifications, and characteristics.

    20. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    21. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing of drug products is not appropriate for the duties they perform.

    22. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    23. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Bioresearch MonitoringCitations not published

Regulations FDA cited here

The 20 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Show all 20

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006039994 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006039994. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.