Biokosmes Srl
Via Dei Livelli 1, Bosisio Parini, Italy
FEI 3005488444DUNS 436948830
FDA has 5 inspections on file for Biokosmes Srl in Bosisio Parini, Italy (FEI 3005488444), from 2010 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant is Biokosmes s.r.l. -socio unico (D-U-N-S 436948830).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2010–2026
- 0 OAI · 4 VAI · 1 NAI
- Inspections with 483 observations shown
- 4 of 5
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written record not kept of program and validation data
A written record of the program along with appropriate validation data has not been maintained in situations where backup data is eliminated by computerization or other automated processes.
GMP Training Frequency
GMP training is not conducted on a continuing basis to assure that employees remain familiar with CGMP requirements applicable to them.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Labeling Control Records and Label Copies
The batch production and control records are deficient in that they do not include specimen and copy of labeling.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Buildings of Suitable Size, Construction, Location
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable size, construction and location to facilitate cleaning, maintenance, and proper operations.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Verification of component addition
Each component is not added to the batch by one person and verified by a second person..
Show 4 more citations
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Sampling and testing procedures described
Written specifications for laboratory controls do not include a description of the sampling procedures used.
Sample size - test intervals
The written stability program for drug products does not include test intervals based on statistical criteria for each attribute examined to assure valid estimates of stability.
Instruments, apparatus, et. al. not meeting specs
The use of apparatus not meeting established specifications was observed.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Show 4 more citations
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.
Calibration/Inspection/Checking not done
Routine calibration, inspection and checking of mechanical equipment is not performed according to a written program designed to assure proper performance.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Product rework documentation, DHR {see also 820.184}
Rework and reevaluation activities have not been fully documented in the device history record.
Software validation for automated processes
Software used as part of production has not been validated for its intended use according to an established protocol.
Regulations FDA cited here
The 16 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.68Automatic, mechanical, and electronic equipment3 of 4
- 21 CFR 211.160General requirements3 of 4
- 21 CFR 211.25Personnel qualifications2 of 4
- 21 CFR 211.67Equipment cleaning and maintenance2 of 4
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 4
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
- 21 CFR 211.42Design and construction features1 of 4
- 21 CFR 211.101Charge-in of components1 of 4
Show all 16
- 21 CFR 211.111Time limitations on production1 of 4
- 21 CFR 211.113Control of microbiological contamination1 of 4
- 21 CFR 211.125Labeling issuance1 of 4
- 21 CFR 211.166Stability testing1 of 4
- 21 CFR 211.180General requirements1 of 4
- 21 CFR 211.188Batch production and control records1 of 4
- 21 CFR 820.70Production and process controls1 of 4
- 21 CFR 820.90Nonconforming product1 of 4
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Biokosmes s.r.l. -socio unicoD-U-N-S 436948830
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3005488444 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3005488444. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.