Accu Bio-Chem Laboratories LLC
1755 Victory Blvd, Glendale, California, United States
FEI 3004876794DUNS 146789651
FDA has 6 inspections on file for Accu Bio-Chem Laboratories LLC in Glendale, California (FEI 3004876794), from 2010 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Feb 10, 2023. FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations IV). No court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.68(b), 21 CFR 211.192 and 21 CFR 211.160(b).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for analysis, through Dec 31, 2026. Its registrant is ACCU BIO-CHEM LABS (D-U-N-S 146789651).
Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2010–2024
- 2 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 4 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 2 requests, latest Oct 4, 2024
- Warning letters
- · CDER · Division of Pharmaceutical Quality Operations IV ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Following/documenting laboratory controls
Established laboratory control mechanisms are not documented at the time of performance.
Comparison of Test Results to Specifications
Laboratory records are deficient in that they do not include a statement of the results of tests and how they compare to the established specifications.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Laboratory Test Method Verification
Verification of the suitability of the testing methods is deficient in that they are not documented on the laboratory records.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and completeness.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance11 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Establishment of calibration procedures
Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug product containers and drug products conform to appropriate standards of identity, strength, quality and purity.
Written records kept in individual logs
Written records of major equipment maintenance and use are not included in individual equipment logs.
SOPs not followed / documented
Written production and process control procedures are not documented at the time of performance.
Show 6 more citations
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints and investigations conducted for each drug product.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Test method modification records do not include
Records maintained of any modification of an established method employed in testing do not include the reason for the modification.
Calibration/Inspection/Checking not done
Routine calibration and checking of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.
Buildings not maintained in good state of repair
Buildings used in the processing of a drug product are not maintained in a good state of repair.
Written record of investigation incomplete
Written records of investigations into do not include the conclusions and follow-up.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Buildings of Suitable Size, Construction, Location
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable size to facilitate cleaning, maintenance, and proper operations.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Oct 4, 2024. Each one asked for a Form 483.
Inspection ending Jul 30, 2024VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 4, 2024FDA-FOIA-2024-8758Form 483· 1 of 5 sitesClosed
Inspection ending Aug 31, 2021OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Mar 10, 2022FDA-FOIA-2022-1941Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.68Automatic, mechanical, and electronic equipment3 of 4
- 21 CFR 211.160General requirements3 of 4
- 21 CFR 211.194Laboratory records3 of 4
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
- 21 CFR 211.42Design and construction features1 of 4
- 21 CFR 211.56Sanitation1 of 4
- 21 CFR 211.58Maintenance1 of 4
Show all 11
- 21 CFR 211.100Written procedures; deviations1 of 4
- 21 CFR 211.180General requirements1 of 4
- 21 CFR 211.182Equipment cleaning and use log1 of 4
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Division of Pharmaceutical Quality Operations IV · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- ACCU BIO-CHEM LABSD-U-N-S 146789651
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004876794 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004876794. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.