Skip to content

Formatech Inc.

200 Bulfinch Dr, Andover, Massachusetts, United States

FEI 3003220485

FDA has 2 inspections on file for Formatech Inc. in Andover, Massachusetts (FEI 3003220485), from 2010 to 2011. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 13 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2010–2011
2 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    2. In-process materials specifications

      In-process specifications are not determined by the application of suitable statistical procedures where appropriate.

    3. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    5. Buildings not maintained in good state of repair

      Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair.

    Show 8 more citations
    1. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    2. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    3. Buildings of Suitable Size, Construction, Location

      Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.

    4. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include parameters relevant to the operation.

    5. Changes to Procedures Not Reviewed, Approved

      Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit.

    6. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    7. Equipment for Environmental Control

      Equipment for adequate control over air pressure and dust is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.

    8. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Component identity verification

      Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.

    2. Calibration/Inspection/Checking not done

      Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance.

    3. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    4. Test methods

      The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.

    5. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    Show 7 more citations
    1. Reserve samples identified, representative, stored

      Reserve drug product samples are not representative of each lot or batch of drug product.

    2. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    3. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing, and packing of a drug product are not maintained in a good state of repair.

    4. Microbiological Contamination Exam

      Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.

    5. Buildings of Suitable Size, Construction, Location

      Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable size and construction to facilitate cleaning, maintenance, and proper operations.

    6. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.

    7. Temperature / Humidity Controls

      Aseptic processing areas are deficient regarding humidity controls.

Regulations FDA cited here

The 14 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.

Show all 14

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3003220485 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3003220485. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.