FDA has 3 inspections on file for BENEV Company Inc in Mission Viejo, California (FEI 3003205477), from 2009 to 2013. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Dec 14, 2010. FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . No court action is filed under this FEI.
10 regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 3, 2009–2013
- 2 OAI · 0 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance18 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.
Results not used for expiration dates, storage cond.
Results of stability testing are not used in determining expiration dates.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.
Drains--Size, Back-siphonage Prevention
Drains are not of adequate size.
Show 13 more citations
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Review of representative number of batches
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Label storage access limited to authorized personnel
Access to the storage area for labels and labeling materials is not limited to authorized personnel.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Labeling control records including specimens or copies
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.
Rejecting When Specifications Not Met
Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
In-process samples representative, identified properly
Samples taken of in-process materials for determination of conformance to specifications are not representative.
Valid stability test methods
The written stability program for drug products does not include reliable, meaningful, and specific test methods.
Drug products - samples representative, identified properly
Samples taken of drug products for determination of conformance to written specifications are not representative.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance25 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Results not used for expiration dates, storage cond.
Results of stability testing are not used in determining expiration dates.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
Quality control unit review of records
Drug product production and control records, are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.
Show 20 more citations
Record maintenance 1 year (except exempt OTC)
All records of production and control associated with a batch of drug product are not maintained at least one (1) year after the expiration date.
No written record of investigation
Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components and in-process materials conform to appropriate standards of identity, strength, quality and purity.
Sample size - test intervals
The written stability program for drug products does not include sample size based on statistical criteria for each attribute examined to assure valid estimates of stability.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing and specifications.
Rejecting When Specifications Not Met
Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not reviewed and approved by the quality control unit.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Signatures and dates--person who performs test
Laboratory records do not include the initials or signature of the person who performs each test.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.
Adverse Drug Experience
Complaint procedures are deficient in that they do not include provisions that allow for the review to determine if the complaints represent serious and unexpected adverse drug experiences which are required to be reported to FDA.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Equipment construction - reactive surfaces
Equipment surfaces that contact components and in-process materials are reactive, additive or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements.
Written program not followed
The written stability testing program is not followed.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Retention time of reserve samples, in general
Reserve samples for drug products are not retained for one year after the expiration date of the drug product.
In-process samples representative, identified properly
Samples taken of in-process materials for determination of conformance to specifications are not representative.
Regulations FDA cited here
The 18 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.25Personnel qualifications2 of 2
- 21 CFR 211.67Equipment cleaning and maintenance2 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 2
- 21 CFR 211.100Written procedures; deviations2 of 2
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.166Stability testing2 of 2
- 21 CFR 211.180General requirements2 of 2
- 21 CFR 211.182Equipment cleaning and use log2 of 2
Show all 18
- 21 CFR 211.192Production record review2 of 2
- 21 CFR 211.194Laboratory records2 of 2
- 21 CFR 211.48Plumbing1 of 2
- 21 CFR 211.63Equipment design, size, and location1 of 2
- 21 CFR 211.65Equipment construction1 of 2
- 21 CFR 211.122Materials examination and usage criteria1 of 2
- 21 CFR 211.170Reserve samples1 of 2
- 21 CFR 211.186Master production and control records1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
- 21 CFR 211.198Complaint files1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3003205477, one row per refused product line.
1 refusal on 2018-09-12 · charged NOT LISTED on 1, FRNMFGREG on 1 · no FDA sample analysis
FDA firm profile- 2018-09-12
MISCELLANEOUS PATENT MEDICINES, ETC.66VBK99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of Northern Border ImportsAEK-5096513-3/11/1E
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003205477 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003205477. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.