RIMOS SRL
Via Aldo Manuzio Il Vecchio 15, Mirandola, Italy
FEI 3002926090
FDA has one inspection on file for RIMOS SRL in Mirandola, Italy (FEI 3002926090). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDRH).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 8 citations from this inspection, all under 21 CFR Part 820, the device quality system rules. They are listed below. One FOIA request asked FDA for the 483 from a later inspection, ending Jul 23, 2026, that FDA's Data Dashboard doesn't list yet.
21 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2012
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest Sep 16, 2026
- Warning letters
- · CDRH ↗
- Import refusals
- 21 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDevices · Compliance: Devices8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Mixups
Labeling and packaging operations were not controlled to prevent labeling mix-ups.
Quality Audits - defined intervals
Quality audits were not performed at sufficient frequency to determine whether the quality system activities and results comply with quality system procedures.
Personnel
Personnel do not have the necessary training and experience to perform their jobs.
Documentation
Process validation activities and results have not been adequately documented and adequately approved.
Evaluation of suppliers, contractors, etc., requirements
Requirements that must be met by suppliers have not been adequately established.
Show 3 more citations
Buildings
Buildings are not of suitable design and do not contain sufficient space to perform necessary operations, prevent mix-ups, and assure orderly handling of product.
Incoming acceptance records, documentation
Acceptance or rejection of incoming product was not documented.
Calibration procedures - content
Calibration procedures do not include specific directions and limits for accuracy and precision.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Sep 16, 2026. It asked for a Form 483.
Inspection ending Jul 23, 2026
1 request. Not listed in FDA’s Data Dashboard yet.
- Sep 16, 2026FDA-FOIA-2026-8951Form 483· 1 of 2 sitesOpen
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 820.22Quality audit1 of 1
- 21 CFR 820.25Personnel1 of 1
- 21 CFR 820.50Purchasing controls1 of 1
- 21 CFR 820.70Production and process controls1 of 1
- 21 CFR 820.72Inspection, measuring, and test equipment1 of 1
- 21 CFR 820.75Process validation1 of 1
- 21 CFR 820.80Receiving, in-process, and finished device acceptance1 of 1
- 21 CFR 820.120Device labeling1 of 1
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDRH · DevicesFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002926090, one row per refused product line.
21 refusals from 2016-12-23 to 2026-05-29 · charged DEVICEGMPS on 14, NO 510(K) on 10 · no FDA sample analysis
FDA firm profile- 2026-05-29
SYRINGE, PISTON80FMF
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
Division of Southeast Imports1FX-1207215-2/10002/1
- 2026-05-29
ENTERAL SYRINGES WITH ENTERAL SPECIFIC CONNECTORS78PNR
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
Division of Southeast Imports1FX-1200403-1/10002/1
- 2026-03-27
NEEDLE, HYPODERMIC, SINGLE LUMEN80FMI
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
NO 510(K) 801(a)(3); 502(o) Misbranding
Division of Southeast Imports1FX-1235041-8/10002/2
- 2026-03-27
NEEDLE, HYPODERMIC, SINGLE LUMEN80FMI
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
NO 510(K) 801(a)(3); 502(o) Misbranding
Division of Southeast Imports1FX-1235041-8/10002/1
- 2025-10-08
NEEDLE, HYPODERMIC, SINGLE LUMEN80FMI
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
NO 510(K) 801(a)(3); 502(o) Misbranding
Division of Southeast Imports799-2488267-5/10002/2
Show 16 more
- 2025-10-08
NEEDLE, HYPODERMIC, SINGLE LUMEN80FMI
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
NO 510(K) 801(a)(3); 502(o) Misbranding
Division of Southeast Imports799-2488267-5/10002/1
- 2024-05-17
ANIMAL MEDICAL DEVICES, NEC68ZYG99
FALSE 502(a), 801(a)(3); MISBRANDING
708NODIREC 502(f)(1), 801(a)(3); MISBRANDING
Division of Southeast Imports799-0505108-3/11/1
- 2023-07-12
GUIDE, NEEDLE, SURGICAL79GDF
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
Division of Southeast Imports799-5375861-2/11/1
- 2022-11-09
INTRODUCER, SYRINGE NEEDLE80KZH
NO PMA 501(f)(1)(B), 801(a)(3); ADULTERATION
Division of Southeast Imports799-1465735-8/11/1
- 2022-06-07
GUIDE, NEEDLE, SURGICAL79GDF
DV QUALITY 501(c); 801(a)(3) Adulteration
Division of Southeast Imports799-8884364-4/11/1
- 2022-05-27
GUIDE, NEEDLE, SURGICAL79GDF
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
Division of Southeast Imports799-8833263-0/11/1
- 2021-10-08
ANIMAL MEDICAL DEVICES, NEC68ZYG99
DV QUALITY 501(c); 801(a)(3) Adulteration
Division of Southeast Imports799-4649376-3/11/1
- 2021-03-27
NEEDLE, CATHETER79GCB
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
NO 510(K) 801(a)(3); 502(o) Misbranding
Division of Southeast Imports799-1495525-6/11/1
- 2018-09-30
OTHER ANIMAL, N.E.C. DEVICE/DIAG PROD FOR ANIMAL68XYY99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
NO 510(K) 801(a)(3); 502(o) Misbranding
Division of Southeast Imports799-6952686-9/11/1
- 2018-09-24
DEVICE, GENERAL MEDICAL80LDQ
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
STD LABEL 502(s), 801(a)(3); MISBRANDING
Division of Southeast Imports799-7355360-2/11/1
- 2018-08-23
OTHER ANIMAL, N.E.C. DEVICE/DIAG PROD FOR ANIMAL68XDY99
DE IMP GMP 801(a)(1); NON CONFORMING MANUFACTURING PRACTICES
Division of Southeast Imports799-6006787-1/11/1
- 2016-12-23
NEEDLE, ACUPUNCTURE, SINGLE USE80MQX
NOT LISTED 502(o), 801(a)(3); MISBRANDING
NO PMA 501(f)(1)(B), 801(a)(3); ADULTERATION
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
NO 510(K) 801(a)(3); 502(o) Misbranding
New Orleans District Office799-7778010-0/2/2
- 2016-12-23
NEEDLE, ACUPUNCTURE, SINGLE USE80MQX
NOT LISTED 502(o), 801(a)(3); MISBRANDING
NO PMA 501(f)(1)(B), 801(a)(3); ADULTERATION
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
NO 510(K) 801(a)(3); 502(o) Misbranding
New Orleans District Office799-7778010-0/2/1
- 2016-12-23
NEEDLE, ACUPUNCTURE, SINGLE USE80MQX
NOT LISTED 502(o), 801(a)(3); MISBRANDING
NO PMA 501(f)(1)(B), 801(a)(3); ADULTERATION
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
NO 510(K) 801(a)(3); 502(o) Misbranding
New Orleans District Office799-7778010-0/1/1
- 2016-12-23
SYRINGE, PISTON80FMF
DE IMP GMP 801(a)(1); NON CONFORMING MANUFACTURING PRACTICES
Division of Southeast Imports799-7764599-8/2/1
- 2016-12-23
NEEDLE, HYPODERMIC, SINGLE LUMEN80FMI
NOT LISTED 502(o), 801(a)(3); MISBRANDING
NO PMA 501(f)(1)(B), 801(a)(3); ADULTERATION
DEVICEGMPS 501(h), 801(a)(1); ADULTERATION
NO 510(K) 801(a)(3); 502(o) Misbranding
Division of Southeast Imports799-7764599-8/1/1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002926090 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002926090. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.