Skip to content

Medical Products Laboratories, Inc.

9990 Global Rd, Philadelphia, Pennsylvania, United States

FEI 2513595DUNS 002290302

FDA has 8 inspections on file for Medical Products Laboratories, Inc. in Philadelphia, Pennsylvania (FEI 2513595), from 2010 to 2023. The latest ended on and was classified VAI, voluntary action indicated. FDA issued a warning letter on (CDER).

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below. One FOIA request has asked FDA for this inspection's 483, and two more for the 483 from a later inspection, ending Oct 16, 2025, that FDA's Data Dashboard doesn't list yet.

No court action or import refusal is filed under this FEI.

Seven regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis, relabeling and repacking, through Dec 31, 2027. Its registrant is Medical Products Laboratories, Inc. (D-U-N-S 002290302).

Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
8, 2010–2023
0 OAI · 6 VAI · 2 NAI
Inspections with 483 observations shown
5 of 8
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
3 requests, latest Jun 10, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

    2. Quarantine of Rejected Components et. al.

      Rejected components and drug product containers are not controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.

    3. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Calibration/Inspection/Checking not done

      Routine calibration and inspection of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.

    2. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and sampling plans designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    3. Extent of discrepancy, failure investigations

      Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    5. Quarantine of Rejected Components et. al.

      Rejected components are not controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.

    Show 8 more citations
    1. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    2. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used.

    3. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

    4. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair.

    5. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    6. Storage under appropriate conditions

      Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected.

    7. Valid stability test methods

      The written stability program for drug products does not include meaningful test methods.

    8. Production processes

      Production processes were not controlled to ensure that a device conforms to its specifications.

  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  7. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Buildings not maintained in good state of repair

      Buildings used in the manufacturing of a drug product are not maintained in a good state of repair.

  8. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices14 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Documentation - review in response to changes or deviations

      There is no documentation of the review and evaluation of a process performed in response to changes or process deviations.

    2. Accurate reproduction

      The batch production and control records are deficient in that they are not an accurate reproduction of the appropriate master production or control record.

    3. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    4. Containers sampled so as to prevent contamination

      Containers are not sampled in a manner designed to prevent contamination of their contents and other components.

    5. Management review - Lack of or inadequate procedures

      Procedures for management review have not been established.

    Show 9 more citations
    1. Document review, approval by designated individual

      Documents were not approved by designated individual(s) prior to issuance .

    2. Lack of or inadequate process validation

      A process whose results cannot be fully verified by subsequent inspection and test has not been validated according to established procedures.

    3. Environmental control Lack of or inadequate procedures

      Procedures to control environmental conditions have not been adequately established.

    4. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.

    5. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

    6. Lack of or inadequate organizational structure

      The organizational structure has not been adequately established and maintained to ensure that devices are designed and produced in accordance with 21 CFR 820.

    7. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    8. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    9. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Jun 10, 2026. Each one asked for a Form 483.

  • Inspection ending Oct 16, 2025

    2 requests. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Jan 28, 2026. FDAgent holds no copy that FDA posted.

    1. Jun 10, 2026FDA-FOIA-2026-5687Form 483Records released
    2. Dec 29, 2025FDA-FOIA-2025-14392Form 483· 1 of 5 sitesRecords released
  • Inspection ending Jul 13, 2023VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Nov 16, 2023FDA-FOIA-2023-10281Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 18 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 8 inspections, with how many of them cited each.

Show all 18

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis, relabeling, repacking
Registration runs through
Dec 31, 2027
Registrant
Medical Products Laboratories, Inc.D-U-N-S 002290302

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 2513595 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 2513595. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.