Skip to content

Health Plus Incorporated

13837 Magnolia Ave, Chino, California, United States

FEI 2027164

FDA has 6 inspections on file for Health Plus Incorporated in Chino, California (FEI 2027164), from 2010 to 2021. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations IV).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 16 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No court action or import refusal is filed under this FEI.

Three regulations were cited at more than one inspection: 21 CFR 211.100(a), 21 CFR 211.166(a) and 21 CFR 211.22(d).

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
6, 2010–2021
2 OAI · 4 VAI · 0 NAI
Inspections with 483 observations shown
4 of 6
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance16 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not followed.

    2. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.

    3. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    5. Changes to Procedures Not Reviewed, Approved

      Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit and reviewed and approved by the quality control unit.

    Show 11 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    2. Prepared for each batch, include complete information

      Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.

    3. Training , Education , Experience overall

      Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training and experience required to perform their assigned functions.

    4. Rejecting When Specifications Not Met

      Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.

    5. Cleaning SOPs/instructions

      Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.

    6. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    7. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    8. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    9. Written program not followed

      The written stability testing program is not followed.

    10. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    11. Test methods

      The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    2. Annual visual exams of drug products

      Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Documentation of Sampling Performed

      The batch production and control records are deficient in that they do not include documentation of sampling performed.

    2. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    4. Investigations made into any unexplained discrepancy

      Batch production and control records do not include the results of any investigation made into any unexplained discrepancy, whether or not the batch of drug product had already been distributed.

    5. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.

    2. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing and packing of drug products is not appropriate for the duties they perform.

    3. Personnel dating/signing equipment log

      The persons double-checking the cleaning and maintenance are not dating and signing or initialing the equipment cleaning and use log.

Regulations FDA cited here

The 18 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 6 inspections, with how many of them cited each.

Show all 18

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 2027164 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 2027164. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.