Skip to content

Hawthorne Products, Inc

16828 N State Road 167n, Dunkirk, Indiana, United States

FEI 1824900DUNS 085616605

FDA has 5 inspections on file for Hawthorne Products, Inc in Dunkirk, Indiana (FEI 1824900), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

11 regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is Hawthorne Products, Inc (D-U-N-S 085616605).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
5, 2009–2025
0 OAI · 5 VAI · 0 NAI
Inspections with 483 observations shown
4 of 5
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
1 request, latest Jul 11, 2025
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
  2. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Destruction of excess labels with lot numbers

      Excess labeling bearing lot or control numbers is not destroyed.

    2. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    3. Cleaning/maintenance records not kept

      Records are not kept for the cleaning of equipment.

    4. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    5. Procedures to be written and followed

      Procedures describing the handling of all written and oral complaints regarding a drug product are not established.

    Show 8 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    2. Calibration - at intervals, written program, remedial action

      The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.

    3. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that conform to appropriate standards of identity, strength, quality and purity.

    4. Items to cover on annual reviews

      Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.

    5. Distinctive ID or code not recorded in batch record

      The batch records do not record the distinctive to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.

    6. Component identification test

      Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.

    7. Quality control unit review of records

      Drug product production and control records, are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

    8. Second person sign off

      Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards.

  3. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices11 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Manufacturing Instructions and Specifications

      The master production and control records are deficient in that they do not include complete sampling and testing.

    2. Laboratory equipment calibration records

      Laboratory records do not include complete records of the periodic calibration of laboratory instruments, apparatus, gauges, and recording devices.

    3. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    4. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    5. Test methods

      The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.

    Show 6 more citations
    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Calibration - at intervals, written program, remedial action

      The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.

    3. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    5. Theoretical Yield and Percentages

      The master production and control records are deficient in that they do not include a statement of theoretical yield and minimum, maximum, and yield percentages.

    6. Written complaint record to be maintained at facility

      A written record of each complaint is not maintained in a file designated for drug product complaints at the facility where the drug product was manufactured, processed or packed.

  4. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices18 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    4. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

    5. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    Show 13 more citations
    1. Cleaning/maintenance records not kept

      Records are not kept for the maintenance, cleaning, sanitizing, and inspection of equipment.

    2. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include maintenance and cleaning schedules.

    3. Written in-process control procedures

      Written procedures are not established that describe the in-process controls, tests, and examinations to be conducted on appropriate samples of in-process materials of each batch.

    4. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and standards designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

    5. Review of representative number of batches

      Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    6. In process materials - conformance to written specs

      Laboratory controls do not include a determination of conformance to written specifications for in-process materials.

    7. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

    8. In-process materials characteristics testing

      In-process materials are not tested for identity, strength, quality, and purity and approved or rejected by the quality control unit after storage for long periods.

    9. Sampling and testing procedures described

      Written specifications for laboratory controls do not include a description of the sampling and testing procedures used.

    10. Items to cover on annual reviews

      Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.

    11. Lot or control number assigned

      The drug product is not identified with a lot or control number that permits the determination of the history of the manufacture and control of the batch.

    12. Documentation of Actual Yield and Theoretical Yield

      The batch production and control records are deficient in that they do not include a statement of the actual yield and percentage of theoretical yield.

    13. Certificates of Testing (Containers, Closures)

      Certificates of testing of are accepted in lieu of testing without establishing the reliability of the supplier's test results through appropriate validation of the test results at appropriate intervals.

  5. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices22 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Sampling and testing plans not described

      Sampling and testing plans for drug products are not described in written procedures which include the method of sampling.

    2. Component Test Records

      The component records do not include the results of tests or examinations performed.

    3. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, approval, and rejection of components, drug product containers, and closures.

    4. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    5. Destruction of excess labels with lot numbers

      Excess labeling bearing lot or control numbers is not destroyed.

    Show 17 more citations
    1. Active Ingredient Name and Weight

      The master production and control records are deficient in that they do not include the name and weight of each active ingredient per dosage unit or unit of weight statement of total weight or measure of any dosage unit.

    2. Items to cover on annual reviews

      Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints and investigations conducted for each drug product.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    4. Distribution Record Requirements

      Distribution records do not contain the lot or control number of drug product.

    5. Calibration/Inspection/Checking not done

      Routine calibration of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.

    6. Cleaning/maintenance records not kept

      Records are not kept for the maintenance and cleaning of equipment.

    7. Certificates of Testing (Containers, Closures)

      Certificates of testing of are accepted in lieu of testing without establishing the reliability of the supplier's test results through appropriate validation of the test results at appropriate intervals.

    8. Description of containers and closures

      Batch production and control records do not include a description of drug product containers and closures used for each batch of drug product produced.

    9. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    10. Approval and review of procedures

      Written procedures are not drafted, reviewed and approved by the appropriate organizational units.

    11. Signature and checking of records -- 2 persons

      The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.

    12. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    13. Actual yield, % of theoretical yield

      The batch production and control records do not include a statement of the percentage of theoretical yield at appropriate stages of processing for each batch of drug product produced.

    14. Strict control not exercised over labeling issued

      Strict control is not exercised over labeling issued for use in drug product labeling operations.

    15. Individual inventory record

      Records fail to include an individual inventory record of each component, reconciliation of the use of each component, drug product container, and drug product closure with sufficient information to allow determination of any associated batch or lot of drug product.

    16. Labeling control records including specimens or copies

      Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.

    17. Description of containers, labels, et. al.

      Master production and control records lack a specimen or copy of each label and all other labeling and the signatures and dates entered by the person or persons responsible for the approval of labeling.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jul 11, 2025. It asked for a Form 483.

  • Inspection ending May 21, 2025VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 24, 2025. FDAgent holds no copy that FDA posted.

    1. Jul 11, 2025FDA-FOIA-2025-8595Form 483· 1 of 4 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 24 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 5 inspections, with how many of them cited each.

Show all 24

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2026
Registrant
Hawthorne Products, IncD-U-N-S 085616605

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1824900 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1824900. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.