Iso-Tex Diagnostics, Inc.

1511 County Road 129, Alvin, Texas, United States

FEI 1626310DUNS 181202995

FDA has 12 inspections on file for Iso-Tex Diagnostics, Inc. in Alvin, Texas (FEI 1626310), from 2008 to 2026. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three of the five FOIA requests for this site have asked FDA for this inspection's 483.

FDA has issued 3 warning letters under this FEI, the latest on (CDER · Division of Pharmaceutical Quality Operations II). No court action or import refusal is filed under this FEI.

Eight regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant is Iso-Tex Diagnostics, Inc. (D-U-N-S 181202995).

Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
12, 2008–2026
4 OAI · 3 VAI · 5 NAI
Inspections with 483 observations shown
7 of 12
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
5 requests, latest May 11, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

12 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Calibration/Inspection/Checking not done

      Routine inspection and checking of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.

    2. Calibration - at intervals, written program, remedial action

      The calibration of instruments and recording devices is not done at suitable intervals in accordance with an established written program.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

    5. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

    2. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.

    3. Washing and toilet facilities are deficient

      Washing and toilet facilities lack air driers or single-service towels and cleanliness.

    4. Establishment of calibration procedures

      Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed and deficiently written or followed.

    5. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    Show 2 more citations
    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Buildings of Suitable Size, Construction, Location

      Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.

  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

  6. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Unapproved and Misbranded Drugs10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Calibration/Inspection/Checking not done

      Routine calibration, inspection, and checking of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.

    2. Distinctive ID or code not recorded in batch record

      The batch records do not record the distinctive identification number and code to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.

    3. Written sanitation procedures lacking

      There is a lack of written procedures assigning responsibility, providing cleaning schedules, and describing in sufficient detail the methods, equipment and materials to be used for sanitation.

    4. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

    5. Written records kept in individual logs

      Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.

    Show 5 more citations
    1. Handling and Storage to Prevent Contamination

      There was a failure to handle and store components at all times in a manner to prevent contamination.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    3. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    5. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

  7. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch Monitoring1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Interval

      Periodic reports of non-alert adverse drug experiences have not been submitted yearly for an application which was approved three or more years ago.

  10. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.

    2. Calibration/Inspection/Checking not done

      Routine calibration of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.

    3. Written calibration / inspection records not kept

      Records of the calibration checks of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.

  11. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    2. Written sanitation procedures lacking

      There is a lack of written procedures providing cleaning schedules and describing in sufficient detail the methods, equipment and materials to be used for sanitation.

    3. Written sanitation procedures not followed

      Written procedures for sanitation are not followed.

    4. Equipment for Environmental Control

      Equipment for adequate control over air pressure is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.

    5. Buildings of Suitable Size, Construction, Location

      Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.

    Show 4 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    3. Defined areas of adequate size for operations

      The control systems necessary to prevent contamination or mix-ups are deficient.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

  12. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on May 11, 2026. Each one asked for a Form 483.

  • Inspection ending Feb 3, 2026OAI

    3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Apr 23, 2026. FDAgent holds no copy that FDA posted.

    1. May 11, 2026FDA-FOIA-2026-4823Form 483· 1 of 5 sitesWithdrawn
    2. May 5, 2026FDA-FOIA-2026-4459Form 483Records released
    3. Apr 7, 2026FDA-FOIA-2026-3452Form 483· 1 of 5 sitesRecords released
  • Inspection ending Feb 10, 2023OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jan 25, 2024FDA-FOIA-2024-829Form 483Closed
  • Inspection date not given

    1 request. FDA released records in answer to a request for its Form 483 + EIR on Jan 5, 2024. FDAgent holds no copy that FDA posted.

    1. Nov 16, 2023FDA-FOIA-2023-10278Form 483 + EIRReleased in part

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 16 sections of 21 CFR in FDA’s published citations for 7 of this facility’s 12 inspections, with how many of them cited each.

Show all 16

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, analysis
Registration runs through
Dec 31, 2027
Registrant
Iso-Tex Diagnostics, Inc.D-U-N-S 181202995

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1626310 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1626310. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.