FDA has 7 inspections on file for Medline Industries, LP in Northfield, Illinois (FEI 1417592), from 2008 to 2024. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDRH).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 5 citations from this inspection: 4 under 21 CFR Part 820, the device quality system rules, and 1 under 21 CFR Part 803, the device adverse event reporting rules. They are listed below. Two of the six FOIA requests for this site have asked FDA for this inspection's 483, and one more for the 483 from a later inspection, ending Aug 29, 2025, that FDA's Data Dashboard doesn't list yet.
4 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 820.50.
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 7, 2008–2024
- 1 OAI · 2 VAI · 4 NAI
- Inspections with 483 observations shown
- 2 of 7
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 6 requests, latest May 28, 2026
- Import refusals
- 4 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDevices · Compliance: Devices5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Purchasing controls, Lack of or inadequate procedures
Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements have not been adequately established.
Lack of or inadequate procedures
Procedures for corrective and preventive action have not been adequately established.
Lack of or inadequate complaint procedures
Procedures for receiving, reviewing, and evaluating complaints by a formally designated unit have not been adequately established.
Design changes - Lack of or Inadequate Procedures
Procedures for design change have not been adequately established.
Individual Report of Malfunction
An MDR report was not submitted within 30 days of receiving or otherwise becoming aware of information that reasonably suggests that a marketed device has malfunctioned and would be likely to cause or contribute to a death or serious injury if the malfunction were to recur.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: DevicesCitations not published
- NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: DevicesNone
- NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: DevicesNone
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Production processes
Production processes were not complete to ensure that a device conforms to its specifications.
Analysis of data sources
Appropriate sources of quality data are not adequately analyzed to identify existing and potential causes of nonconforming product and other quality problems.
Purchasing controls, Lack of or inadequate procedures
Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements were not complete.
Evaluation of suppliers, contractors, etc., requirements
Adequate quality requirements that must be met by suppliers were not implemented.
Investigation
Certain indicators of nonconformities are not investigated to determine the cause of the nonconformity.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Six requests to FDA under the Freedom of Information Act named this site, most recently on May 28, 2026. Each one asked for a Form 483.
Inspection ending Aug 29, 2025
1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Mar 16, 2026. FDAgent holds no copy that FDA posted.
- Oct 31, 2025FDA-FOIA-2025-12503Form 483· 1 of 5 sitesRecords released
Inspection ending Jan 22, 2024OAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 30, 2024FDA-FOIA-2024-6621Form 483· 1 of 4 sitesClosed
- Jun 25, 2024FDA-FOIA-2024-5566Form 483· 1 of 3 sitesClosed
Inspection ending Apr 6, 2022VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Dec 6, 2023FDA-FOIA-2023-10885Form 483Closed
Inspection date not given
2 requests. FDA released records in answer to a request for its Form 483 on Sep 3, 2026. FDAgent holds no copy that FDA posted.
- May 28, 2026FDA-FOIA-2026-5354Form 483 + EIROpen
- Feb 27, 2026FDA-FOIA-2026-2061Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 6 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 820.50Purchasing controls2 of 2
- 21 CFR 820.100Corrective and preventive action2 of 2
- 21 CFR 803.50If I am a manufacturer, what reporting requirements apply to me?1 of 2
- 21 CFR 820.30Design controls1 of 2
- 21 CFR 820.70Production and process controls1 of 2
- 21 CFR 820.198Complaint files1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDRH · DevicesLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDRH · DevicesFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1417592, one row per refused product line.
4 refusals from 2023-05-08 to 2026-09-08 · charged FRNMFGREG on 2, HOLES on 2 · FDA sample analysis on 2
FDA firm profile- 2026-09-08
DRESSING, WOUND, DRUG79FRO
REGISTERED 502(o), 801(a)(3); MISBRANDING
Division of Northern Border Imports98F-0130567-9/30001/3
- 2025-02-13
GLOVE, PATIENT EXAMINATION, POLY80LZA
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
HOLES 501(c); 801(a)(3) Adulteration
FDA sample analysis
Division of Northern Border ImportsSCS-7973812-0/41/1
- 2025-02-13
GLOVE, PATIENT EXAMINATION, POLY80LZA
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
HOLES 501(c); 801(a)(3) Adulteration
FDA sample analysis
Division of Northern Border ImportsSCS-7973812-0/31/1
- 2023-05-08
ANTIBIOTIC N.E.C.56YBJ99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
Division of Southeast ImportsAV3-0055168-4/241/1
Other FEIs recorded as Medline Industries, LP
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Medline Industries, LPFEI 1000138386Mundelein, Illinois, United States
Last inspected 2026-07-22OAI
Medline Industries, LPFEI 1417411Arlington Heights, Illinois, United States
Last inspected 2026-02-06VAI
Medline Industries, LPFEI 1000514656Waukegan, Illinois, United States
Last inspected 2025-12-11NAI
Medline Industries, LPFEI 3003983334Waukegan, Illinois, United States
Last inspected 2025-10-14OAI
Medline Industries, LPFEI 3011508621Hartland, Wisconsin, United States
Last inspected 2025-07-18OAI
Medline Industries, LPFEI 2125337North Mankato, Minnesota, United States
Last inspected 2024-04-11VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1417592 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1417592. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.