PRIMROSE CANDY CO
4111 W Parker Ave, Chicago, Illinois, United States
FEI 1412287DUNS 005086855
FDA has 5 inspections on file for PRIMROSE CANDY CO in Chicago, Illinois (FEI 1412287), from 2009 to 2021. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the three FOIA requests for this site asked FDA for the 483 from a later inspection, ending Mar 13, 2026, that FDA's Data Dashboard doesn't list yet.
No warning letter, court action or import refusal is filed under this FEI.
20 regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is Primrose Candy Company (D-U-N-S 005086855).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2009–2021
- 0 OAI · 5 VAI · 0 NAI
- Inspections with 483 observations shown
- 5 of 5
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest FY2023
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Label storage access limited to authorized personnel
Access to the storage area for labels and labeling materials is not limited to authorized personnel.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without.
Show 7 more citations
Approval and review of procedures
Written procedures are not drafted, reviewed and approved by the appropriate organizational units and reviewed and approved by the quality control unit.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of of the drug product.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration - at intervals, written program, remedial action
The calibration of instruments, apparatus, gauges and recording devices is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Show 2 more citations
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance11 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions.
No written record of investigation
Written records are not made of investigations into unexplained discrepancies.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Show 6 more citations
Drug products - samples representative, identified properly
Samples taken of drug products for determination of conformance to written specifications are not representative.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, sampling plans, and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance22 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Adequate lab facilities not available
Adequate lab facilities for testing and approval or rejection of components, in-process materials, and drug products are not available to the quality control unit.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Show 17 more citations
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Individual inventory record
Records fail to include an individual inventory record of each component, reconciliation of the use of each component, and drug product container with sufficient information to allow determination of any associated batch or lot of drug product.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing and packaging of the drug product.
Records not made readily available to FDA
Records associated with drug product production and distribution and within the retention period for such records, were not made readily available for authorized inspection.
Procedures Written and Followed
Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to approve and reject all drug products.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.
No written record of investigation
Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
Drug products - samples representative, identified properly
Samples taken of drug products for determination of conformance to written specifications are not representative.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing, control, instructions, sampling, and specifications.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Reprocessing procedures not written or followed
Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not written.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance25 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Calibration/Inspection/Checking not done
Routine calibration of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and sampling plans designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing, control, instructions, and sampling.
Show 20 more citations
Drug product sample
Drug product samples are not representative of the entire batch.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and written.
Individual inventory record
Records fail to include an individual inventory record of each component, reconciliation of the use of each component, drug product container, and drug product closure with sufficient information to allow determination of any associated batch or lot of drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used, description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance, and instructions for protection of clean equipment from contamination prior to use.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, packing, and holding.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Procedures Written and Followed
Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Sampling/testing of labeling/packaging materials
Labeling and packaging materials are not representatively sampled and examined upon receipt and before use in packaging and labeling of a drug product.
Reprocessing procedures not written or followed
Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not written and followed.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies.
Determination not to conduct investigation of complaint
The written record did not include the reason an investigation was found not to be necessary when an investigation into the failure of a batch or any of its components to meet specifications was not conducted.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Adequate lab facilities not available
Adequate lab facilities for testing and approval or rejection of components and drug products are not available to the quality control unit.
Packaging line inspection documentation
Results of inspection of packaging and labeling facilities are not documented in the batch production records.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.
Inspection ending Mar 13, 2026
1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Jun 5, 2026. FDAgent holds no copy that FDA posted.
- May 20, 2026FDA-FOIA-2026-5158Form 483· 1 of 5 sitesRecords released
Inspection date not given
2 requests. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2023-1632Form 483 + EIRClosed
- Aug 12, 2021FDA-FOIA-2021-5273Inspection recordsClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 26 sections of 21 CFR in FDA’s published citations for this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures5 of 5
- 21 CFR 211.110Sampling and testing of in-process materials and drug products5 of 5
- 21 CFR 211.160General requirements5 of 5
- 21 CFR 211.166Stability testing5 of 5
- 21 CFR 211.192Production record review5 of 5
- 21 CFR 211.194Laboratory records4 of 5
- 21 CFR 211.25Personnel qualifications3 of 5
- 21 CFR 211.186Master production and control records3 of 5
Show all 26
- 21 CFR 211.22Responsibilities of quality control unit2 of 5
- 21 CFR 211.63Equipment design, size, and location2 of 5
- 21 CFR 211.103Calculation of yield2 of 5
- 21 CFR 211.111Time limitations on production2 of 5
- 21 CFR 211.115Reprocessing2 of 5
- 21 CFR 211.122Materials examination and usage criteria2 of 5
- 21 CFR 211.125Labeling issuance2 of 5
- 21 CFR 211.165Testing and release for distribution2 of 5
- 21 CFR 211.180General requirements2 of 5
- 21 CFR 211.184Component, drug product container, closure, and labeling records2 of 5
- 21 CFR 211.188Batch production and control records2 of 5
- 21 CFR 211.198Complaint files2 of 5
- 21 CFR 211.67Equipment cleaning and maintenance1 of 5
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 5
- 21 CFR 211.100Written procedures; deviations1 of 5
- 21 CFR 211.113Control of microbiological contamination1 of 5
- 21 CFR 211.130Packaging and labeling operations1 of 5
- 21 CFR 211.170Reserve samples1 of 5
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- Primrose Candy CompanyD-U-N-S 005086855
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1412287 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1412287. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.