Canberra Corporation
3610 N Holland Sylvania Rd, Toledo, Ohio, United States
FEI 1000508133
FDA has 5 inspections on file for Canberra Corporation in Toledo, Ohio (FEI 1000508133), from 2010 to 2014. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.113(a) and 21 CFR 211.165(e).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 5, 2010–2014
- 0 OAI · 4 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 5
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance22 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration/Inspection/Checking not done
Routine inspection of electronic equipment is not performed according to a written program designed to assure proper performance.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Measured components for manufacturing
Components for drug product manufacturing are not measured and subdivided as appropriate.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 17 more citations
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of investigations conducted for each drug product.
Test methods
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written, and followed.
Label storage access limited to authorized personnel
Access to the storage area for labels and labeling materials is not limited to authorized personnel.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions, sampling and testing procedures, specifications, special notations, and precautions to be followed.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing, and holding of a drug product lack the education, training, and experience required to perform their assigned functions.
Following/documenting laboratory controls
Established test procedures and laboratory control mechanisms are not followed and documented at the time of performance.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and sampling plans designed to assure that components, in-process materials, and drug products conform to appropriate standards of identity, strength, quality and purity.
Inadequate number of personnel
The number of qualified personnel is inadequate to perform and supervise the manufacture, processing, packing, and holding of each drug product.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size, and suitably located to facilitate operations for its intended use and cleaning and maintenance.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals with provisions for remedial action in the event accuracy and/or precision limits are not met.
Status of Each Lot Identified
Each lot of components, drug product containers, and closures was not appropriately identified as to its status in terms of being quarantined, approved or rejected.
Retention time of reserve samples, in general
Reserve samples for active ingredients and drug products are not retained for one year after the expiration date of the drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and followed.
Calculations performed are in the records
Laboratory records do not include a record of all calculations performed in connection with the test.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Test methods
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.
Show 1 more citation
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Regulations FDA cited here
The 19 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.113Control of microbiological contamination2 of 2
- 21 CFR 211.165Testing and release for distribution2 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.58Maintenance1 of 2
- 21 CFR 211.63Equipment design, size, and location1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
- 21 CFR 211.80General requirements1 of 2
Show all 19
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.101Charge-in of components1 of 2
- 21 CFR 211.122Materials examination and usage criteria1 of 2
- 21 CFR 211.137Expiration dating1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.170Reserve samples1 of 2
- 21 CFR 211.180General requirements1 of 2
- 21 CFR 211.182Equipment cleaning and use log1 of 2
- 21 CFR 211.186Master production and control records1 of 2
- 21 CFR 211.192Production record review1 of 2
- 21 CFR 211.194Laboratory records1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000508133 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000508133. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.