Defender SD Manufacturing LLC
3443 Tripp Ct, San Diego, California, United States
FEI 1000135880
FDA has 9 inspections on file for Defender SD Manufacturing LLC in San Diego, California (FEI 1000135880), from 2009 to 2022. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One FOIA request has asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 9, 2009–2022
- 2 OAI · 6 VAI · 1 NAI
- Inspections with 483 observations shown
- 5 of 9
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest Aug 12, 2024
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to fully investigate errors that have occurred.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit.
Plumbing System Defects
The plumbing system contains defects that could contribute to the contamination of drug products.
Show 3 more citations
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Theoretical yield statement including percentages
Master production and control records lack a statement of theoretical yield including the maximum and minimum percentages of theoretical yield beyond which investigation is required.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Deviations from laboratory control requirements
Deviations from written specifications and test procedures are not justified.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Show 1 more citation
Handling and Storage to Prevent Contamination
There was a failure to handle and store components, drug product containers, and closures at all times in a manner to prevent contamination.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Adequate lab facilities not available
Adequate lab facilities for testing and approval or rejection of components are not available to the quality control unit.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning SOP/inspection
Procedures for the cleaning and maintenance of equipment are deficient regarding inspection of the equipment for cleanliness immediately before use.
Calibration/Inspection/Checking not done
Routine inspection and checking of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Approve or reject procedures or specs
The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality, and purity of drug products.
Individual inventory record
Records fail to include an individual inventory record of each component, reconciliation of the use of each component, drug product container, and drug product closure with sufficient information to allow determination of any associated batch or lot of drug product.
Show 5 more citations
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Rejected Material Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the holding of rejected before disposition.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: DevicesCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Aug 12, 2024. It asked for a Form 483.
Inspection ending Sep 22, 2022OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Aug 12, 2024FDA-FOIA-2024-7161Form 483· 1 of 5 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 16 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 9 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features4 of 5
- 21 CFR 211.160General requirements4 of 5
- 21 CFR 211.22Responsibilities of quality control unit3 of 5
- 21 CFR 211.113Control of microbiological contamination3 of 5
- 21 CFR 211.67Equipment cleaning and maintenance2 of 5
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 5
- 21 CFR 211.100Written procedures; deviations2 of 5
- 21 CFR 211.48Plumbing1 of 5
Show all 16
- 21 CFR 211.80General requirements1 of 5
- 21 CFR 211.125Labeling issuance1 of 5
- 21 CFR 211.142Warehousing procedures1 of 5
- 21 CFR 211.180General requirements1 of 5
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 5
- 21 CFR 211.186Master production and control records1 of 5
- 21 CFR 211.192Production record review1 of 5
- 21 CFR 211.194Laboratory records1 of 5
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000135880 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000135880. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.