Owen Biosciences Inc.
7053 Revenue Dr, Baton Rouge, Louisiana, United States
FEI 1000132299DUNS 790003045
FDA has 7 inspections on file for Owen Biosciences Inc. in Baton Rouge, Louisiana (FEI 1000132299), from 2009 to 2026. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the five FOIA requests for this site has asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Six regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and labeling, through Dec 31, 2027. Its registrant is Owen Biosciences Inc (D-U-N-S 790003045).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 7, 2009–2026
- 3 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 6 of 7
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 5 requests, latest Jul 13, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
No written record of investigation
Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Testing in same container - closure system
The written stability program does not assure testing of the drug product in the same container-closure system as that in which the drug product is marketed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Stability testing records not included
Laboratory records do not include complete records of all stability testing performed.
Show 1 more citation
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Identification of containers, lines, equipment
All compounding and storage containers, processing lines and major equipment used during the production of a batch of drug product is not properly identified at all times to indicate contents and the phase of processing of the batch.
Weighing/measuring/subdividing supervision
Component weighing, measuring and subdividing operations are not adequately supervised.
Written warehousing procedures established/followed
Procedures describing the warehousing of drug products are not followed.
Accurate reproduction
The batch production and control records are deficient in that they are not an accurate reproduction of the appropriate master production or control record.
Training , Education , Experience overall
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions.
Show 4 more citations
Complete instructions, procedures, specifications et. al.
Master production and control records lack specifications.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing and processing.
Calibration/Inspection/Checking not done
Routine calibration, inspection and checking of mechanical equipment is not performed according to a written program designed to assure proper performance.
Supervisor Training/Education/Experience
Individuals responsible for supervising the manufacture and processing of a drug product lack the training to perform their assigned functions in such a manner as to assure the drug product has the safety, identity, strength, quality and purity that it purports or is represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Test devices not meeting specifications
Test devices are deficient in that instruments not meeting established specifications are used.
Calibration/Inspection/Checking not done
Routine inspection and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Accelerated stability studies
Accelerated stability studies, combined with basic stability information, used to support tentative expiration dates are not supported with ongoing full shelf life studies.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Calibration/Inspection/Checking not done
Routine calibration and checking of equipment is not performed according to a written program designed to assure proper performance.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Accelerated stability studies
Accelerated stability studies, combined with basic stability information, used to support tentative expiration dates are not supported with ongoing full shelf life studies.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Labeling control records including specimens or copies
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.
Control procedures fail to include the following
Control procedures fail to include adequacy of mixing to assure uniformity and homogeneity.
Adequate number of batches on stability
An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.
Review of representative number of batches
Written procedures are not established and followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Show 5 more citations
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Written records kept in individual logs
Written records of major equipment maintenance and use are not included in individual equipment logs.
Testing and standardization of standards et. al.
Laboratory records do not include complete records of any testing and standardization of laboratory reference standards, reagents, and standard solutions.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate designed to assure that components and drug product containers conform to appropriate standards of identity, strength, quality and purity.
GMP Training Frequency
GMP training is not conducted with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Five requests to FDA under the Freedom of Information Act named this site, most recently on Jul 13, 2026. Each one asked for a Form 483.
Inspection ending May 15, 2026OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 13, 2026FDA-FOIA-2026-6645Form 483· 1 of 5 sitesRecords released
Inspection ending Mar 27, 2025OAI
4 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 11, 2025. FDAgent holds no copy that FDA posted.
- May 15, 2026FDA-FOIA-2026-4997Form 483· 1 of 5 sitesWithdrawn
- Sep 29, 2025FDA-FOIA-2025-11394Form 483· 1 of 4 sitesRecords released
- Jul 10, 2025FDA-FOIA-2025-8498Form 483Records released
- May 22, 2025FDA-FOIA-2025-4543Form 483· 1 of 5 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 19 sections of 21 CFR in FDA’s published citations for 6 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.166Stability testing4 of 6
- 21 CFR 211.192Production record review4 of 6
- 21 CFR 211.25Personnel qualifications3 of 6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment3 of 6
- 21 CFR 211.160General requirements3 of 6
- 21 CFR 211.22Responsibilities of quality control unit2 of 6
- 21 CFR 211.180General requirements2 of 6
- 21 CFR 211.188Batch production and control records2 of 6
Show all 19
- 21 CFR 211.194Laboratory records2 of 6
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 6
- 21 CFR 211.101Charge-in of components1 of 6
- 21 CFR 211.105Equipment identification1 of 6
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 6
- 21 CFR 211.113Control of microbiological contamination1 of 6
- 21 CFR 211.137Expiration dating1 of 6
- 21 CFR 211.142Warehousing procedures1 of 6
- 21 CFR 211.165Testing and release for distribution1 of 6
- 21 CFR 211.182Equipment cleaning and use log1 of 6
- 21 CFR 211.186Master production and control records1 of 6
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling
- Registration runs through
- Dec 31, 2027
- Registrant
- Owen Biosciences IncD-U-N-S 790003045
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000132299 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000132299. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.