FDA has 10 inspections on file for Constant Irwindale, Inc. in Irwindale, California (FEI 1000125593), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three FOIA requests have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Six regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
10, 2009–2024
0 OAI · 7 VAI · 3 NAI
Inspections with 483 observations shown
4 of 10
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
3 requests, latest Apr 7, 2025
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    3. Training , Education , Experience overall

      Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions.

    4. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    5. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    Show 2 more citations
    1. Written procedures not established/followed

      Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    2. No written record of investigation

      Written records are not always made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.

  2. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
  4. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  5. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Review of representative number of batches

      Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    2. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    3. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

  8. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  9. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food Additives18 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

    2. Actual yield, % of theoretical yield

      The batch production and control records do not include a statement of the actual yield at appropriate stages of processing for each batch of drug product produced.

    3. Defined areas of adequate size for operations

      The separate or defined areas necessary to prevent contamination or mix-ups are deficient.

    4. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    5. Approve or reject procedures or specs

      The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality, and purity of drug products.

    Show 13 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Specific information required in individual logs

      Individual equipment logs do not show product and lot number of each batch processed.

    3. Identification of persons involved, each significant step

      Batch production and control records do not include the identification of the persons performing each significant step in the operation, for each batch of drug product produced.

    4. Inadequate number of personnel

      The number of qualified personnel is inadequate to perform the manufacture and processing of each drug product.

    5. Handling and Storage to Prevent Contamination

      There was a failure to handle and store drug product containers and closures at all times in a manner to prevent contamination.

    6. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function.

    7. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    8. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    9. Calibration - at intervals, written program, remedial action

      The calibration of instruments and apparatus is not done at suitable intervals in accordance with an established written program.

    10. Personnel dating/signing equipment log

      The persons performing the cleaning and maintenance are not signing or initialing the equipment cleaning and use log.

    11. Aseptic Processing Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.

    12. Washing and toilet facilities are deficient

      Washing and toilet facilities lack hot and cold water.

    13. Testing Containers & Closures Conformity with Specs

      Containers and closures are not tested for conformance with all appropriate written procedures.

  10. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Washing and toilet facilities are deficient

      Washing and toilet facilities lack hot and cold water and cleanliness.

    2. Written calibration procedures

      Written calibration procedures for instruments, apparatus, gauges, and recording devices are deficient in that they do not include specific directions, schedules, limits for accuracy and precision, and provisions for remedial action if limits are not met.

    3. Written Procedures Not Followed

      Written procedures are not followed for the testing and approval of components and closures.

    4. Written procedures not established/followed

      Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    5. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the testing and approval of components.

    Show 2 more citations
    1. Written program not followed

      The written stability testing program is not followed.

    2. Plumbing System Defects

      The plumbing system contains defects that could contribute to the contamination of drug products.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Apr 7, 2025. Each one asked for a Form 483.

  • Inspection ending Nov 15, 2024VAI

    3 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Apr 7, 2025FDA-FOIA-2025-3218Form 483· 1 of 3 sitesMerged with another request
    2. Mar 7, 2025FDA-FOIA-2025-2190Form 483· 1 of 3 sitesClosed
    3. Dec 23, 2024FDA-FOIA-2024-11218Form 483· 1 of 3 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 17 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 10 inspections, with how many of them cited each.

Show all 17

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1000125593 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1000125593. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.