Skip to content

Grandpa's Compounding Pharmacy, Inc. Form 483, September 2013

FDA issued this Form 483 to Grandpa's Compounding Pharmacy, Inc. in Placerville, California (FEI 3006365166) at the end of a drug inspection that ended September 10, 2013. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Sep 10, 2013
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
3,781 days after the inspection
Facility
FEI 3006365166
Placerville, California

FDA's 10 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Equipment Design, Size and Location

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

  2. Equipment construction - reactive surfaces

    Equipment surfaces that contact drug products are reactive, additive or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements.

  3. Written calibration / inspection records not kept

    Records of the calibration checks of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.

  4. Buildings not maintained in good state of repair

    Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair.

  5. Procedures for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.

  6. Cleaning / Sanitizing / Maintenance

    Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product.

  7. Clothing appropriate for duties performed

    Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.

  8. Supervisor Training/Education/Experience

    Individuals responsible for supervising the manufacture and processing of a drug product lack the education, training, and experience to perform their assigned functions in such a manner as to assure the drug product has the safety, identity, strength, quality and purity that it purports or is represented to possess.

  9. Air Supply

    Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

  10. Statement of methods and data

    Laboratory records do not include a statement of the location of data that establish that the methods used in the testing of the sample meet proper standards of accuracy and reliability as applied to the product tested.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterMay 2, 2014CDER · 234 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3006365166, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.