Vitti Labs, LLC
834 W Kansas St Ste C, Liberty, Missouri, United States
FEI 3015365441
FDA has 2 inspections on file for Vitti Labs, LLC in Liberty, Missouri (FEI 3015365441), from 2021 to 2024. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 14 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two of the seven FOIA requests for this site have asked FDA for this inspection's 483.
FDA issued a warning letter on (CBER · Office of Biological Products Operations - Division 2). No court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.100(a), 21 CFR 211.113(b) and 21 CFR 211.42(c)(10)(v).
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2021–2024
- 1 OAI · 0 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 7 requests, latest FY2023
- Warning letters
- · CBER · Office of Biological Products Operations - Division 2 ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Records not made readily available to FDA
Records associated with drug product control and within the retention period for such records, were not made readily available for authorized inspection.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Temperature / Humidity Controls
Aseptic processing areas are deficient regarding temperature and humidity controls.
Show 9 more citations
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
input/output verification
Input to and output from records or data are not checked for accuracy.
Reserve samples identified, representative, stored
Reserve drug product samples are not retained and stored under conditions consistent with product labeling.
Floors, walls, ceiling surfaces
Aseptic processing areas are deficient in that walls and ceilings are not smooth and/or hard surfaces that are easily cleanable.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Equipment for Environmental Control
Equipment for adequate control over air pressure, micro-organisms and dust is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Written procedures lacking for use of pesticides etc.
Written procedures are lacking for the use of cleaning and sanitizing agents designed to prevent the contamination of equipment.
Component identification test
Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.
- NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic Products8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Aseptic Processing Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.
Components withheld from use pending release
Each lot of drug product containers and closures is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Show 3 more citations
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing and processing.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the to produce aseptic conditions.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Seven requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.
Inspection ending Mar 15, 2024OAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 18, 2026. FDAgent holds no copy that FDA posted.
- Sep 15, 2026FDA-FOIA-2026-8917Form 483· 1 of 5 sitesRecords released
- Sep 25, 2025FDA-FOIA-2025-11250Form 483Withdrawn
Inspection ending Dec 20, 2021NAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2023-4526Form 483Closed
Inspection date not given
4 requests. FDA released records in answer to a request for its Form 483 + EIR on Oct 18, 2022. FDAgent holds no copy that FDA posted.
- Sep 24, 2026FDA-FOIA-2026-9261Form 483Closed, no reply from requester
- Aug 11, 2025FDA-FOIA-2025-9602Form 483Closed, no reply from requester
- Oct 1, 2024FDA-FOIA-2024-8564Inspection recordsReleased in part
- Aug 25, 2022FDA-FOIA-2022-6189Form 483 + EIRReleased in part
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features2 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 2
- 21 CFR 211.100Written procedures; deviations2 of 2
- 21 CFR 211.113Control of microbiological contamination2 of 2
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 2
- 21 CFR 211.56Sanitation1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
Show all 14
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.170Reserve samples1 of 2
- 21 CFR 211.180General requirements1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
- 21 CFR 211.194Laboratory records1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCBER · Office of Biological Products Operations - Division 2 · BiologicsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3015365441 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3015365441. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.