Skip to content

Fagron Compounding Services

8710 E 34th St N, Wichita, Kansas, United States

FEI 3012104093

FDA has 5 inspections on file for Fagron Compounding Services in Wichita, Kansas (FEI 3012104093), from 2016 to 2025. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three FOIA requests have asked FDA for this inspection's 483.

FDA has issued 2 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
5, 2016–2025
4 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
5 of 5
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
5 posted
Requested under FOIA
3 requests, latest May 14, 2026
Warning letters
· CDER ↗
2 on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    2. Written procedures not established/followed

      Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    4. Inadequate number of personnel

      The number of qualified personnel is inadequate to perform the manufacture of each drug product.

    5. Buildings of Suitable Size, Construction, Location

      Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable size to facilitate cleaning, maintenance, and proper operations.

    Show 1 more citation
    1. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate aseptic procedures

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, A. Your firm released batches of sterile drug products even though positive microbial growth was detected during environmental monitoring (EM) and personnel monitoring (PM) in the ISO 5 aseptic area during batch processing. For example, since 2023, your firm has released a total of 9 batches with positive growth identified on operators' gloved hands, settle plates, or active air samples in the ISO 5 areas for the following products: • Ketamin[e] 10 mg/ml (API) 5 ml Fill in 5 mL Syringe, Lot# [(6) (4) ] 1, 1 CFU of Staphylococcus capitis identified on the right surface sample • PHENYL[e]phrine 0.1 mg/mL PF Inj Soln 10 mL Syringe API, Lot# [(6) (4) ] 1, 1 CFU of Staphylococcus epidermidis identified on the left hand • Norepinephrine Bitartrate 8 mg added to 250 mL 0.9% NaCl Bag, Lot# [(6) (4) ] 1, 1 CFU of Staphylococcus hominis identified on the left glove • Succinylcholine 20 mg/mL Solution, Lot# [(6) (4) ] 1, 1 CFU of Staphylococcus capitis identified on the left glove • Rocuronium Bromide Inj. Solution 10 mg/mL from API, Lot# [(b) (4) ] 1, 1 CFU of Peribacillus simplex identified on the left glove • Oxytocin 30U Inj Sol 500 mL Fill in 500 mL 2-Port IV Bag API Lot# [(b) (4) ] 1, 1 CFU of Metabacillus galliciensis identified on the left hand • Norepinephrine Bitartrate 16 mg added to 250 mL 0.9% NaCl Bag, Lot# [(b) (4) ] 1, 1 CFU of Niallia circulans identified on the right active air sample • Ketamine 50 mg/mL (API) 1 mL Fill in 3 mL Syringe, Lot# [(6) (4) ] 1 CFU of Micrococcus luteus identified on the right active air sample • Lidocaine HCl 2% 20 mg/mL Sol for Inj. PF from API, Lot# [(b) (4) ] 1 CFU of Bacillus licheniformis identified on the left glove Your investigation indicated that syringes and IV bags were filled in a minimally exposed environment for these batches, unlike vials and eye droppers; however, there is no assurance that product sterility was maintained throughout batch processing. B. Your qualification of the cleanrooms after construction was inadequate prior to the resumption of production of sterile products. Your firm reconstructed the production area from January 30, 2023, to February 7, 2023, including the construction of a new Filling Room [ (b) (4) ] by [(6) (4) ] with [(b) (4) ]. However the Change Control 23-CC-006 was inadequate, as it only required the qualification of Filling Room H, the gowning room and the corridor, but the other (b) (4) connected filling rooms were not qualified until the July 2023 qualification before production resumed immediately after the construction was completed. Your firm produced approximately [illegible] batches a day varying from [5][<][illegible] units to [(b) (4) ] units per batch. C. Media fill was not conducted prior to the production of sterile products in the newly constructed Filling Room [ (b) (4) ]. Your firm constructed a new Filling Room [ (b) (4) ] which is equipped with new [illegible] filling equipment and the ISO 5 Laminar Airflow Hoods (LAFHs) transferred from Fill Room ' for the filling of sterile IV bags in February 2023. However, the initial media fill (Protocol Number: FSS-2023-099) for this filling room was not conducted until August 2023. Despite this, the room was put into use for producing IV bags immediately after construction was completed. Your firm produced [b] batches prior to the media fill in Filling Room [#4]. For example, your firm produced the first batch of Norepinephrine Bitartrate 16 mg added to 250 mL 0.9% NaCl Bag, Lot# [(b) (4) ], on February 13, 2023. D. The qualification of ISO 5 Laminar Airflow Hoods used for aseptic production was inadequate. Your [(b) (4)] certifications of HEPA filters conducted in January 2024 and January 2023 revealed multiple occasions of HEPA filter leaks in the ISO 5 aseptic processing areas, deviations in air velocity and discoloration.

      Shortened here; the PDF has the full text.

    2. Observation 2

      Inadequate OOS investigations

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Your investigations of out-of-specification (OOS) results in environmental monitoring (EM), visual inspection failures, and consumer complaints were inadequate for the following: • Since 2023, your firm has reported 22 deviations due to OOS results of gloved hands, settle plates, or active air monitoring in the ISO 5 areas during aseptic batch processing. No definite root causes were identified and therefore no CAPAs were initiated for any of these EM OOS results. For example, your firm reported 1 CFU of Chaetomium globosum on the right glove of an aseptic technician during the production of norepinephrine Bitartrate 8 mg added to 250 mL 0.9% NaCl Bag, Lot# [(b) (4)] dated February 1, 2024 (DEV-2024-0174). Since no definite root causes have been identified for the OOS result, the batch was rejected, and no CAPA was initiated. • Since 2023, your firm has rejected approximately 30 batches of ketamine syringes due to visual inspection failures. Although your firm suggests the cause might be a combination of factors such as [(b) (4)] the units, no definite root causes have been identified. Your firm continues to produce commercial batches of this product. • Your firm has received four complaints regarding Lidocaine-Epinephrine-Tetracaine (L.E.T.) topical gel (Lot # [(b) (4)] ) being discolored. The investigation identified the root cause as inappropriate storage conditions, leading to the oxidation of epinephrine and the resulting color change. However, retention samples stored at your facility were also found to be discolored, which is defined as a critical defect. No definite root causes have been identified for discoloration of products.

    Show observations 3 to 7
    1. Observation 3

      QC unit lacks full responsibilities

      The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products. Specifically, A. Your [(6) (4)] certifications of HEPA filters conducted in January 2024 and January 2023 identified HEPA filter leaks and/or discoloration in the ISO 5 aseptic processing areas; however, no CAPA has been initiated to prevent similar situations from reoccurrence. B. No risk assessment or change control has been initiated for the impact of ongoing adjacent construction on sterile manufacturing. Your firm plans to construct an adjacent [(6) (4)] expansion to the east of the FSSE facility at 8720 East 34th St. North, [(b) (4)] facility upon completion. The construction has started in the second quarter of 2024, with a target completion date of [(o) (4)] 1. However, your firm has not initiated a change control for this project, stating that a change control will be initiated once the new construction [(b) (4)] is [(b) (4)]. Your firm claims there is no impact on current manufacturing before the new construction is completed, but there are no documented records of risk assessment and its impact on current manufacturing.

    2. Observation 4

      Inadequate complaint investigations

      Complaint records are deficient in that they do not include the findings of the investigation and follow-up. Specifically Customer complaint investigations are inadequate because your firm did not thoroughly investigate batches and provide supporting data to determine if a complaint is related to a quality issue. Since 2022, your firm has received complaints about potential infections after using sterile drug products produced at your facility, as follows: • COMP-2023-0581: inflammation resulting in vision loss following the administration of TRIAMCINOLONE acetonide 40 mg/mL Inj Susp PF 2 mL SDV Lot#: [(b) (4)] dated August 25, 2022 • COMP-2022-0423: endophthalmitis following the administration of Avastin Solution for Injection, 2.5 mg/0.1 mL, 0.12 mL Fill, Lot# [(b) (4)] dated June 22, 2022 • COMP-2023-0671: infection following the administration of Moxifloxacin HCl (Avelox) 1.6 mg/mL 1 mL fill in 3 mL Syringe, Lot# [(b) (4)] dated September 14, 2023 • COMP-2023-0680: spinal meningitis following the administration of TRIAMCINOLONE acetonide 40 mg/mL Inj Susp PF 1 mL SDV, Lot# [(b) (4)] dated September 18, 2023 • COMP-2024-0250: diffuse corneal swelling following the administration of Lidocaine 1%/Phenylephrine 1.5% BSS PF/SF Inj Soln 1 mL SYR Lot# [(b) (4)] dated May 17, 2024 Your firm conducted an investigation for each case without identifying any deficiencies; however, no sterility tests were performed on retention samples from the batches related to these adverse event reports.

    3. Observation 5

      Inadequate laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate designed to assure that conform to appropriate standards of identity, strength, quality and purity. Specifically, During the walkthrough of the warehouse where [(b) (4)] incubators were located, I observed that all environmental monitoring [(b) (4)] plates were placed in a [(b) (4)] for incubation without any visible gaps. For example, I observed EM plates for Moxifloxacin HCl (Avelox) 1.6 mg/mL 1 mL fill in 3 mL Syringe, Lot# [(b) (4)] were placed in a [(b) (4)] for incubation. Currently, all environmental monitoring samples collected during production of sterile drug products were placed in [(b) (4)] incubators for microbial growth testing in these incubators. However, your firm has not validated this method using known bacterial strains under the same conditions. Your growth promotion testing was conducted in the microbiology laboratory in a different location using [r4l] plates that were unsealed. There is no documented evidence or study demonstrating the impact of this practice on bacterial and fungal growth.

    4. Observation 6

      Missing dosage form on labels

      The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act). Specifically The dosage form is not included on some of your drug product labels. For example, labels for the following drug product do not contain this information: • Tropicamide 1%/Cyclopentolate 1%/Phenylephrine 2.5%/Ketorolac 0.5%, 5 mL in Multi-Dose Dropper Bottle (NDC# 71266-8240-05) • Fentanyl Citrate 2 mcg/mL (100 mcg/50 mL)/Ropivacaine HCl 0.15% (1.5 mg/mL) (75 mg/50 mL), PF, for epidural use only (NDC# 71266-9235-01)

    5. Observation 7

      Missing directions/route on containers

      The container of your outsourcing facility's drug products does not include information required by section 503B(a)(10)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act). Specifically, Your containers do not include the following information: A. Directions for use, including, as appropriate, dosage and administration. Specifically, the route of administration is not included on your containers. Examples of your container labels that do not contain this information include: • Lidocaine 1% (10 mg/mL)/Phenylephrine 1.5% (15 mg/mL) in BSS, PF/SF Injection, 1 mL in 3 mL Single-Use Syringe (NDC# 71266-6360-01) • Epinephrine (1 mg/mL), Sterile Solution for Injection, PF/SF, 1 mL in Single-Use Syringe (NDC# 71266-8120-01) • Phenol Injection 6% (60 mg/mL), In Sterile Water for Injection, 10 mL in Multi-Dose Vial (NDC# 71266-6519-01) • Iohexol (Omnipaque) 300 mg/mL, Sterile Aqueous Injection, PF, Repackaged, 3 mL in Single Use Vial (NDC# 71266-6488-03) • Iohexol (Omnipaque) 240 mg/mL, Sterile Aqueous Injection PF, Repackaged, 5 mL in Single Use Vial (NDC# 71266-6487-05) • Sodium Citrate Injection 4% (40 mg/mL) 30 mL in Multi-Dose Vial (NDC# 71266-6641-01) • Sodium Citrate 4% (40 mg/mL) containing Gentamicin 320 mcg/mL Injection, 30 mL in Multi Dose Vial (NDC# 71266-6670-01) • Sodium Citrate 4% (40 mg/mL) Injection containing Gentamicin 320 mcg/mL, 3 mL in Single Use Syringe for Injection (NDC# 71266-6670-03) • Sodium Citrate 4% (40 mg/mL) Injection containing Gentamicin 320 mcg/mL, 5 mL in Single-Use Syringe for Injection (NDC# 71266-6670-04) • Dexamethasone Sodium Phosphate (dexamethasone phosphate equivalent) 10 mg/mL, Solution for Injection PF, 2 mL in Single-Dose Vial (NDC# 71266-1041-02) • Dexamethasone Sodium Phosphate (dexamethasone phosphate equivalent), 4 mg/mL, Solution for Injection, PF, 2 mL in Single-Dose Vial (NDC# 71266-1051-02) • Methylprednisolone Acetate, 80 mg/mL, Injectable Suspension, PF, 1 mL in Single-Dose Vial (NDC# 71266-1075-01) • Triamcinolone Acetonide, 40 mg/mL, Injectable Suspension, PF, 1 mL in Single-Dose Vial (NDC# 71266-1080-01) • Betamethasone Sodium Phosphate, Sterile Solution for Injection, 6 mg/mL, 2 mL in Single-Dose Vial (NDC# 71266-1025-02)

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lab controls established, including changes

      The establishment of laboratory control mechanisms including any changes thereto, are not reviewed and approved by the quality control unit.

    2. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    3. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    4. Written in-process control procedures

      Written procedures are not established that describe the in-process controls and examinations to be conducted on appropriate samples of in-process materials of each batch.

    5. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    2. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent that would alter the safety, identity, strength, quality or purity of the drug product.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    4. Correct labels during finishing operations

      Packaged and labeled products are not examined during finishing operations to provide assurance that containers and packages in the lot have the correct label.

    5. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    Show 2 more citations
    1. Protective Apparel Not Worn

      Protective apparel is not worn as necessary to protect drug products from contamination.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  6. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    2. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    4. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on May 14, 2026. Each one asked for a Form 483.

  • Inspection ending Aug 8, 2025OAI

    3 requests. In the inspection history above. FDA has posted its Form 483.

    1. May 14, 2026FDA-FOIA-2026-4948Form 483· 1 of 5 sitesWithdrawn
    2. Sep 23, 2025FDA-FOIA-2025-11194Form 483· 1 of 5 sitesRecords released
    3. Aug 15, 2025FDA-FOIA-2025-9904Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 13 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 5 inspections, with how many of them cited each.

Show all 13

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3012104093 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3012104093. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.