SterRx, LLC
141 Idaho Ave, Plattsburgh, New York, United States
FEI 3010840309
FDA has 4 inspections on file for SterRx, LLC in Plattsburgh, New York (FEI 3010840309), from 2017 to 2023. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
FDA issued a warning letter on (CDER · Division Pharmaceutical Quality Operations I). No court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 4, 2017–2023
- 2 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 4
- 1 posted 483 not matched to an inspection
- Warning letters
- · CDER · Division Pharmaceutical Quality Operations I ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for compliance with established standards.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components and closures at all times in a manner to prevent contamination.
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
Show 2 more citations
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Calibration/Inspection/Checking not done
Routine calibration and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 12 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Substances That Come in Contact
Substances required for equipment operations such as lubricants and coolants come in contact with components and closures so as to alter the safety, identity, strength, quality or purity of the drug product beyond the official or other established requirements.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function.
Complaint Record required information
Complaint records are deficient in that they do not include the known reply to complainant.
Show 7 more citations
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
Valid stability test methods
The written stability program for drug products does not include meaningful test methods.
Protection from external factors
Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Cleaning SOPs/equipment protection
Procedures for the cleaning and maintenance of equipment are deficient regarding the protection of clean equipment from contamination prior to use.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Results not used for expiration dates, storage cond.
Results of stability testing are not used in determining expiration dates.
- FDCA 503B(a)(10)
Drug product label, outsourcer facility
The labels of your outsourcing facility’s drug products are deficient.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features3 of 3
- 21 CFR 211.28Personnel responsibilities2 of 3
- 21 CFR 211.63Equipment design, size, and location2 of 3
- 21 CFR 211.67Equipment cleaning and maintenance2 of 3
- 21 CFR 211.113Control of microbiological contamination2 of 3
- 21 CFR 211.166Stability testing2 of 3
- 21 CFR 211.25Personnel qualifications1 of 3
- 21 CFR 211.65Equipment construction1 of 3
Show all 14
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.94Drug product containers and closures1 of 3
- 21 CFR 211.192Production record review1 of 3
- 21 CFR 211.194Laboratory records1 of 3
- 21 CFR 211.198Complaint files1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Division Pharmaceutical Quality Operations I · DrugsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010840309 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010840309. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.