Skip to content

SterRx, LLC Form 483, November 2021

FDA issued this Form 483 to SterRx, LLC in Plattsburgh, New York (FEI 3010840309) at the end of a drug inspection that ended November 4, 2021. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on July 27, 2022.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Mar 2, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Nov 4, 2021
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Mar 2, 2022
118 days after the inspection
Facility
FEI 3010840309
Plattsburgh, New York

FDA's 12 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Equipment Design, Size and Location

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.

  2. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

  3. Substances That Come in Contact

    Substances required for equipment operations such as lubricants and coolants come in contact with components and closures so as to alter the safety, identity, strength, quality or purity of the drug product beyond the official or other established requirements.

  4. Training--operations, GMPs, written procedures

    Employees are not given training in the particular operations they perform as part of their function.

  5. Complaint Record required information

    Complaint records are deficient in that they do not include the known reply to complainant.

  6. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  7. Protective Apparel Not Worn

    Protective apparel is not worn as necessary to protect drug products from contamination.

  8. Valid stability test methods

    The written stability program for drug products does not include meaningful test methods.

  9. Protection from external factors

    Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.

  10. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  11. Air Supply

    Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

  12. Cleaning SOPs/equipment protection

    Procedures for the cleaning and maintenance of equipment are deficient regarding the protection of clean equipment from contamination prior to use.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3010840309, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.