Medical Center Pharmacy, Inc.
2401 N Ocoee St, Cleveland, Tennessee, United States
FEI 3010536120
FDA has 2 inspections on file for Medical Center Pharmacy, Inc. in Cleveland, Tennessee (FEI 3010536120), from 2015 to 2020. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 11 observations from the PDF; they are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2015–2020
- 2 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- 1 posted 483 not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Non-microbial contamination in ISO-5
OBSERVATION 1 Sources of non-microbial contamination were observed in the ISO 5 classified aseptic processing areas that are difficult to clean, particle-generating and visibly dirty. Specifically, on 03/09/2020, we observed the following inside your firm's Laminar Air Flow Hood (LAFH) (ISO-5 classified), (b) (4): A. Visible discoloration what appears to be brown residue (approximately 3-inches in height) was observed on the HEPA screen of your firm's B. Visible discoloration that appears to be residue buildup was observed on the inside corners of the HEPA screen; C. What appeared to be chipped paint was observed on the inside corner D. Gaps were observed on the inside of your firm's transparent acrylic plastic side wall where the workbench meets the wall; E. Caulking was observed on the inside of the HEPA screen. The caulking is not smooth and not easily cleanable; F. Visible lint and residue were observed on the inside wall of the LAFH where the workbench meets the wall; According to your firm's aseptic processing lead pharmacy technician, the status ISO-5 classified; Buffer Room: ISO-7 classified; Anteroom:
- Observation 2
Non-sterile disinfectants/wipes used
OBSERVATION 2 Disinfecting agents and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, A. Your firm uses a non-sterile bactericidal (b) (4), sterile (b) (4) wipes, and non-sterile (b) (4) wipes in your classified areas where aseptic operations are performed, for example, but not limited to, the interior surfaces of ISO-5 equipment: - Laminar Air Flow Hood (LAFH) - firm's Buffer Room; Your firm does not render these products sterile prior to use. According to your firm's aseptic processing lead pharmacy technician who conducts operations in the aseptic processing areas, these non-sterile products are also used in the Buffer Room (ISO 7 classified) and anteroom (ISO 8 classified). According to your firm's prescription log, dated April 2019 - March 2020, your firm produces, but are not limited to the following routes: Route of Administration Injectable (including intrathecals) Ophthalmic Inhalation Drop Irrigation Grand Total
Show observations 3 to 11
- Observation 3
Inadequate remedial action after contamination
OBSERVATION 3 You did not make adequate product evaluation and take remedial action where microbial contamination was found to be present in the ISO 5 classified aseptic processing or areas surrounding the ISO 5 classified area. Specifically, A. According to your firm's Certification Report, dated 16 April 2019, a viable air sample (VAS) revealed: 1. In the LAFH (b) (4) hood 6" from the rear: i. Bacterial Results and Trending: Nineteen (19) CFUs identified as Coag-Neg. Staphylococcus; Micrococcus. 2. In the Anteroom (ISO-7 classified) on the "counter near center of room": i. Fungal Results and Trending: Three (3) CFUs identified as Exophiala; and ii. Bacterial Results and Trending: Seventeen (17) CFUs identified as Coag-Neg. Staphylococcus; Micrococcus. According to your firm's Sterile Log, the following products were produced on 16 April 2019, including but are not limited to: Drug Name Vitamin B Complex High Potency Injection Nandrolone Decanoate 200mg/mL Anastrozole/Testosterone Cypionate Oil Injection 10mg/200mg/mL Estradiol Valerate/Testosterone Cypionate 40mg/50mg per mL B. According to your firm's Certification Report, dated October 2019, a viable air sample revealed: 1. In the Laminar Air Flow Hood (b) (4) center, approximately 6" from the rear: i. Bacterial Results and Trending: (b) (4) CFUs identified as Bacillus; One (1) CFU identified as Bacillus. 2. In the Buffer Room (ISO-7 classified) "top shelf of shelving": i. Bacterial Results and Trending: (b) (4) CFUs; Two (2) CFUs identified as Micrococcus; Four (4) CFUs identified as Non-Sporulating; and Five (5) CFUs identified as Coag-Neg. 3. In the Anteroom (ISO-8 classified) on the "counter near center of room": i. Fungal Results and Trending: Curvularia; Pithomyces; Yeast; Exophiala; and ii. Bacterial Results and Trending: Five (5) CFUs identified as Coag-Neg. Staphylococcus; Micrococcus. According to your firm's Sterile Log, the following products were produced, including but are not limited to: Drug Name Hydromorphone - Preservative Free Your firm does not have a written procedure outlining cleaning requirements. However, your firm's Staff Pharmacist stated a thorough clean should be conducted followed by resampling when environmental monitoring excursions are evident. Review of your firm's (b) (4) and (b) (4) cleaning records do not document a rigorous cleaning was conducted. For example, but are not limited to: - On 4/16/2019, environmental monitoring for VAS was performed by a 3rd party contractor; your firm's (b) (4) cleaning records document non-sterile (b) (4) cleaning was performed on 04/16-19/2019, a (b) (4) clean was performed on 04/30/2019. Your firm documented a (b) (4) clean on 04/20/2019. - On 10/11/2019, environmental monitoring for VAS was performed by a 3rd party contractor; your firm's (b) (4) cleaning records document cleaning and VAS sampling, a (b) (4) clean was performed on 10/21/2019. Your firm documented that a (b) (4) clean was performed in October 2019. Your firm continued aseptic operations until 03/11/2020. To date, a viable air resampling has not been performed. Your firm produces sterile drug products including, but not limited to: injectables (including intrathecals), ophthalmics, and inhalations.
- Observation 4
No endotoxin testing or limits
OBSERVATION 4 Your aseptic processing conditions do not offer sufficient assurance that the finished product will meet an endotoxin specification appropriate for its route of administration. Specifically, according to your firm's pharmacist-in-charge, your firm does not perform endotoxin testing for your finished intrathecal drug products. These preparations are made using non-sterile active pharmaceutical ingredients (APIs). Your firm does not test APIs prior to use in aseptic operations. Furthermore, your firm does not calculate the bacterial endotoxin limit. According to your firm's written procedure, 9.140: endotoxin testing is to be performed at least every [illegible]. In addition, the expiration dates of your intrathecals are inconsistent, for example, but not limited to: Date Drug Name Compounded 02/17/2020 Fentanyl/Morphine/Bupivacaine/Hydromorphone Intrathecal 2500mcg/25mg/7.5mg/10mg 02/20/2020 Clonidine/Baclofen 200mcg/2000mcg 02/19/2020 Baclofen (Preservative Free) 3000mcg/mL Your firm has not performed any stability studies to support these expiration dates.
- Observation 5
Uncalibrated air pressure gauge
OBSERVATION 5 Your aseptic processing conditions do not offer sufficient assurance that the finished product is sterile. Specifically, the air pressure gauge used to perform QC checks have not been calibrated since 2015.
- Observation 6
Inadequate media fill simulations
OBSERVATION 6 Media fills are not conducted to simulate aseptic production operations that represent the most-challenging and stressful conditions. Specifically, on 03/16/2020, your pharmacist-in-charge stated the largest batch size produced at your firm under aseptic operations is 1 (b) (4) (processing simulation) records performed by your firm's personnel, who engage only represent 25% of your firm's largest batch size. In addition, your pharmacist-in-charge stated the most-challenging aseptic operation performed at your facility is for inhalation nebulizers. However, the media fills performed are not representative of those products.
- Observation 7
Inadequate HEPA coverage/airflow
OBSERVATION 7 You had inadequate HEPA filter coverage and airflow. Specifically, A. ISO 5 Classified Areas: 1. LAFH: A loose light fixture with exposed wiring was observed on your firm's LAFH. B. ISO 7 Classified Areas: 1. HEPA filters were not sealed around each perimeter. HEPA filter frames: Missing caulk was observed around the perimeter of the HEPA filter frames that seal the buffer room (ISO-7 classified): i. Located directly above your firm's LAFH (ISO-5 classified); ii. Located approximately 6 feet from your firm's LAFH (ISO-5 classified); and iii. Located approximately 10 feet from your firm's LAFH (ISO-5 classified). 2. Light fixture: Missing caulk was observed around your firm's light fixture. 3. Ceiling: A crack observed in the sheetrock located on your firm's ceiling directly above the ISO 5 hood. C. ISO 8 Classified Areas: 1. HEPA filter frames: A loose bolt and missing caulk were observed around the perimeter of the HEPA filter frames that seal the HEPA in the anteroom (ISO-8 classified); 2. Light fixture: missing gasket/caulking was observed around the perimeter of the light fixture; and 3. (b) (4): lacks established controls - according to your pharmacist-in-charge, beakers (containing drug components used in aseptic operations) are (b) (4) in the anteroom (ISO 8 classified) to the buffer room (ISO 7 classified). 4. In addition, your pharmacist-in-charge admitted the beakers are not always covered or sanitized when (b) (4).
- Observation 8
Supplies not disinfected before entry
OBSERVATION 8 Equipment and Materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, A. On 03/16/2020, your pharmacist-in-charge admitted the glassware (e.g. beakers), containing drug products used in aseptic operations are uncovered and are not disinfected when moved from your firm's unclassified (b) (4) to your firm's buffer room (ISO-7 classified). A beaker remains uncovered in the (b) (4) (unclassified), staging tray (located in the buffer room - ISO 7 classified), and (ISO 5 classified). B. Your lead pharmacy technician, who conducts cleaning on a routine basis, admitted the trash bins are removed from the buffer room (ISO 7 classified) and placed into the anteroom (ISO 8 classified) when the floors are cleaned. However, the trash bins are not disinfected when entering an area of higher classification.
- Observation 9
Dirty, particle-generating adjacent areas
OBSERVATION 9 The area adjacent to the ISO 5 classified aseptic processing areas had difficult to clean, particle-generating and visibly dirty equipment or surface. A. Buffer Room (ISO-7 classified) Area: 1. On 03/09/2020, what appeared to be signs of rust and chipped paint was observed on your firm's LAFH (ISO-5 classified) support frame, located approximately 1-inch from where aseptic operations are performed. 2. On 03/09/2020, what appeared to be dust build-up was observed on your firm's LAFH (ISO-5 classified) support frame, located approximately 1-inch from where aseptic operations are performed. 3. A chair was observed to not be suitable as a cleanroom chair. What appeared to be signs of rust was observed on the back support and legs of the chair, and what appeared to be paint chippings were observed on the upper back portion of the chair. 4. On 03/09/2020, what appeared to be cleaning supplies and drug components are stored. For example, but are not limited to, non-sterile (b) (4) wipes used for cleaning of your firm's area. These non-sterile wipes were observed to be approximately 6 inches from the LAFH; these non-sterile wipes show what appears to be signs of rust located on your firm's storage rack. 5. On 03/09/2020, what appeared to be brown residue was observed on the staging tray, where drug components are placed prior to entering the LAFH (ISO-5 classified). 6. On 03/09/2020, missing caulk, creating a gap, was observed where the floor meets the wall. This area is located approximately 5 feet from the LAFH (ISO-5 classified). 7. On 03/09/2020, a crack was observed on the ceiling approximately 3 feet above the LAFH (ISO-5 classified). B. Anteroom (ISO-8 classified) Area: 1. On 03/09/2020, what appears to be signs of rust was observed on the inside of your firm's (b) (4). According to your pharmacist-in-charge, who oversees aseptic operations, and your lead pharmacy technician, who performs aseptic operations on a routine basis, the (b) (4) used in aseptic operations. According to your lead pharmacy technician, the status of the (b) (4) is (b) (4). 2. On 03/09/2020, what appears to be rust was observed around your firm's light fixture. In addition, missing caulk was observed around the perimeter that seals the fixture to the ceiling. 3. On 03/09/2020, what appears to be a crack alongside the countertop, exposing particle board, located immediately adjacent to the door that leads into the buffer room (ISO-7 classified) was observed. Particle board was also observed on the underside of the countertop where the sink is located. White powder residue was observed on the same countertop.
- Observation 10
Inadequate hazardous drug segregation/controls
OBSERVATION 10 You produced hazardous drugs without providing adequate containment, segregation, cleaning surfaces, cleaning of utensils and cleaning of personnel. Specifically, your firm produces hazardous and non-hazardous, sterile and non-sterile, drug products without adequate segregation. On 03/09/2020, your firm's (b) (4) engaged in aseptic operations on a routine basis, the status (hazardous and non-hazardous) are (b) (4) in this non-dedicated area. Your firm does not use a separate processing schedule when producing hazardous drug products from non-hazardous drug products. For example, but are not limited to, on 1/23/2020, your firm used fluorouracil API (b) (4), a hazardous drug product, to produce a non-sterile cream. However, your firm also engaged in aseptic operations before and after this fluorouracil lot was produced. Furthermore, your firm does not have appropriate cleaning solutions or handling procedures for hazardous drug products. In addition, your technicians do not change gowns between lots; gowns are reused per shift.
- Observation 11
Insufficient sterilization/depyrogenation
OBSERVATION 11 Parameters for sterilization are not lethal to resistant microorganisms. Specifically, your firm uses (b) (4) depyrogenation of glassware used in the production and an endotoxin challenge for the glassware (b) (6).
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Calibration - at intervals, written program, remedial action
The calibration of instruments and gauges is not done at suitable intervals .
Penicillin processing area not kept separate
The operations relating to the manufacture, processing, and packing of penicillin are not performed in facilities separate from those used for other drug products for human use.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.
Show 9 more citations
Equipment for Environmental Control
Equipment for adequate control over air pressure is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Failing drug products not rejected
Drug products failing to meet established standards, specifications, and quality control criteria are not rejected.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing, processing, and packing of drug products is not appropriate for the duties they perform.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 211.28Personnel responsibilities1 of 1
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 1
- 21 CFR 211.63Equipment design, size, and location1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.166Stability testing1 of 1
Show all 10
- 21 CFR 211.167Special testing requirements1 of 1
- 21 CFR 211.194Laboratory records1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010536120 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010536120. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.