Skip to content

MEDGEL PRIVATE LIMITED

Special Economic Zone, Plot No.-19-20, Pharma Zone, Phase-II, Sector-III, Pithampur, Dhar, India

FEI 3010165392DUNS 677385498

FDA has 4 inspections on file for MEDGEL PRIVATE LIMITED in Pithampur, Dhar, India (FEI 3010165392), from 2016 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three of the five FOIA requests for this site have asked FDA for this inspection's 483.

The most recent OAI inspection ended on Jan 27, 2023. FDA issued a warning letter on (CDER). 4 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is MEDGEL PRIVATE LIMITED (D-U-N-S 677385498).

Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
4, 2016–2025
1 OAI · 3 VAI · 0 NAI
Inspections with 483 observations shown
3 of 4
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
5 requests, latest FY2023
Import refusals
4 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    3. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, sampling plans and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

    4. Written procedures not established/followed

      Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    5. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    Show 2 more citations
    1. Equipment for Environmental Control

      Equipment for adequate control over air pressure, humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.

    2. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance11 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Approve or reject components, products

      The quality control unit lacks the responsibility and authority to approve all components.

    3. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    5. Storage under appropriate conditions

      Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.

    Show 6 more citations
    1. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

    2. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

    3. Equipment for Environmental Control

      Equipment for adequate control over humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.

    4. Written record of investigation incomplete

      Written records of investigations into the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.

    5. Defined areas of adequate size for operations

      The control systems necessary to prevent contamination or mix-ups are deficient.

    6. Extent of discrepancy, failure investigations

      Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Following/documenting laboratory controls

      Established test procedures and laboratory control mechanisms are not documented at the time of performance.

    2. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not established and followed.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending Feb 21, 2025VAI

    3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 8, 2025. FDAgent holds no copy that FDA posted.

    1. May 1, 2026FDA-FOIA-2026-4323Form 483Withdrawn
    2. Jun 20, 2025FDA-FOIA-2025-7864Form 483· 1 of 10 sitesRecords released
    3. May 30, 2025FDA-FOIA-2025-7108Form 483· 1 of 3 sitesRecords released
  • Inspection ending Jan 27, 2023OAI

    2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-7324Form 483Closed
    2. FY2023FDA-FOIA-2023-7149Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.

Show all 11

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3010165392, one row per refused product line.

4 refusals from 2023-06-14 to 2023-11-03 · charged DRUG GMPS on 4 · no FDA sample analysis

FDA firm profile
  • 2023-11-03

    ACETAMINOPHEN (ANALGESIC)60LBH01

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Northeast ImportsBPQ-1136665-0/51/1

  • 2023-11-03

    DIPHENHYDRAMINE HCL (ANTI-HISTAMINIC)61XAL18

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Northeast ImportsBPQ-1136665-0/11/1

  • 2023-06-14

    DIPHENHYDRAMINE HCL (ANTI-HISTAMINIC)61XAL18

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Northeast ImportsBPQ-1133987-1/31/1

  • 2023-06-14

    DIPHENHYDRAMINE HCL (ANTI-HISTAMINIC)61XAL18

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Northeast ImportsBPQ-1133654-7/51/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2027
Registrant
MEDGEL PRIVATE LIMITEDD-U-N-S 677385498

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010165392 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010165392. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.