Gland Chemicals Private Limited
& B - 11 Plot No B - 3, Sipcot Industrial Park; & B - 6 To B - 18, Chennai, India
FEI 3008386908DUNS 914234285
Company: GCBC Pharma Private Limited · Linked by exact D-U-N-S match (914234285) in FDA registration data
FDA has 6 inspections on file for Gland Chemicals Private Limited in Chennai, India (FEI 3008386908), from 2011 to 2025. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. Three of the four FOIA requests for this site have asked FDA for this inspection's 483.
FDA has issued 2 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.113(b), 21 CFR 211.192 and 21 CFR 211.80(a).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis and sterilization, through Dec 31, 2027. Its registrant, GCBC Pharma Private Limited (D-U-N-S 914234285), has registered 2 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 6, 2011–2025
- 4 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 4 of 6
- Requested under FOIA
- 4 requests, latest Apr 1, 2026
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Deficient contamination control areas
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations. Your Quality Unit failed to perform a comprehensive assessment of the risks associated with potential cross contamination throughout the facility/common areas. Your firm is engaged in the manufacturing of [©] sterile drug®® (e.g. 00 or) For example. there are no adequate containment practices regarding movement of personnel, handling of laboratory control samples. and production documents, through common areas. Furthermore, your firm failed to conduct a risk assessment to justify the sampling points of your cross-contamination monitoring program to ensure that the sterile products are not cross-contaminated. Specifically, 3 enpLoves sionsgur [= OYEE(S) NAWE AND TITLE (Pit or Toe! - owEsoD rer To Alan A. Rivera, Investigator i Ea | Jose E. Melendez, DDC Investigator | sioverber7, 2025 PAGE a0 | Angelica M. Hernandez, Investigator FORM FDA 483 (09/05) PREVIOUS EDITION OBSOLETE INSPECTIONAL OBSERVATIONS page OF 18 A. The Quality Control and microbiology laboratory located inwe@ Block use a non-dedicated mye to transferm@ samples, in-process, raw material, stability, and finish product samples to QC laboratory. B. ®® in-process finished product and stability samples pending for QC analyses are stored in a common area (control roonge After receipt, the samples are assigned to your Quality Control laboratory analysts that perform samples preparation and analytical tests for gy products simultaneously. C. m® batch production control records and EM control records are sent to officem® for Quality Assurance (QA) review. This office is located inside theme Block. These manufacturing records are transferred from theme Block to officemea through the same main entrance and hallways thatm manufacturing employees use to access their respectivem a manufacturing areas, creating a potential cross-contamination. D. As per your General Manager QA. your Quality Assurance representatives, Quality Control analysts ando® manufacturing operators use a common canteen during lunch. Your Quality Control analysts responsible to prepare and test laboratory samples forme along with your Quality Assurance employees that reviewm@ BMRs, use the same hallways and join the ®@ manufacturing operators during lunch creating a potential source for cross-contamination. Moreover, it was informed by your General Manager- QA. that your QC laboratory has not validated analytical test methods to detect and quantify the presence ofwme in ®@ sterile drugme and vice versa. E. Your “Cross Contamination Study Program", SOP Number: QA050-02, Effective Date: June 27, 2025. is deficient in that does not consider personnel monitoring to ensure that personnel flow is not introducing cross-contamination into the ga Blocks. Furthermore, there is no risk assessment to justify that the current sampling locations are scientifically sound to ensure that the established sampling points and areas represent the worst locations. The current sampling locations were selected randomly.
- Observation 2
Inadequate sterilization validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. A. The aseptic process simulation (media fill) studies carried out in thebo blocks are inadequate. During our review of the media fill batch records used to qualify the filling lines in co processes, we found that an assignable cause is not provided for all vials rejected during filling and stoppering activities. The rejected vials summarized below were not included with the incubation of the aseptically filled batches. B. Your Quality Unit failed to perform a comprehensive assessment of the risks associated with aseptic processing operations. Specifically, your Quality Unit did not conduct a formal, documented risk assessment to determine the frequency, duration, and contamination risk associated with inherent and corrective aseptic process interventions that might occur during your aseptic filling operations. As a result, the bo blocks lack a scientifically sound basis for assessing the impact of operators” interventions on aseptic processing lines. establishing adequate EM controls, and ensuring that aseptic processing is performed under process conditions designed to prevent microbial contamination. C. There is no assurance that corrective interventions requiring the removal of glass vials from different zones of the filling line are accurately simulated during aseptic process simulation (APS) studies.
Show observations 3 to 5
- Observation 3
Aseptic procedures not followed
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. Smoke studies conducted in the ge vial filling lines ®OT do not accurately reflect the conditions that would be encountered during routine manufacturing processes. Technicians involved in the studies show multiple instances of poor aseptic technique and non-compliance with established procedures observed, including but not limited to: Smoke study®@ Block: A. During thege interventions. fix the®® stopper length chute and fix th®® ®@ the manufacturing operator was observed sanitizing his gloved hands immediately prior to performing the finger-dab monitoring. This practice may reduce microbial recovery and does not reflect the true aseptic conditions of the gloves during routine operations. B. During theme intervention. cleaning of ge spillage under Grade A. it was observed that the manufacturing operator did not adequately sanitize the {gg hose used to remove the sterile - near the {ye prior to introducing it into the ISO 5 area. In addition. the hose is kept at the edge of the (y) LAF (filling room classification is Grade B) without any protective covering on the hose opening, exposing aseptic core area (ISO 5) to potential contamination. C. It was observed that airflow laminarity is not maintained during the demonstration of airflow direction among filling line (ISO 5 area). | LAF andw@ LAF. The gq LAF is positioned at the front side of the filling line during the assembly process, and both the filling line and the [gy LAF are kept with the {j throughout the assembly interventions. The video shows an interruption in the unidirectional airflow. Smoke study we Block: A. During the {yj intervention, remove the protective cover from the stopper bowl and replace used forceps with new one, it was noted that only the manufacturing operator positioned at the front side of the filling line was subjected to finger dab monitoring. The operator positioned at the rear side of the line, who also participated in the intervention, was not monitored. This practice fails to ensure that all personnel involved in this intervention are assessed for potential contamination risk. B. During the intervention, loading ofg API canister, it was observed the design of the dispensing area (ISO 5 area) does not allow the manufacturing operator to perform the loading process of the canister smoothly or with deliberate, controlled movements. This restricted space increases the risk of unintentional contact of the ga with equipment and surfaces. which may compromise aseptic technique. At the conclusion of the intervention, it was further observed that the manufacturing operator used theme to remove them @ me Thisaction may create a risk of cross-contamination between jg land is inconsistent with adequate aseptic gq handling techniques expected in controlled environments. C. During the intervention, loading the API canister, it was observed that the fingers and sleeve of the operatol contacted thege stopper of sterilelyg | filled canister. This action represents an unacceptable breach of aseptic technique and potentially increase the risk of contaminating the sterile API. At the conclusion of the intervention, it was further observed that the manufacturing operator removed th sing the wo which is inconsistent with adequat removal procedure and presents an additional potential risk of cross-contamination. D. During thew intervention, opening o valve to load API intome it was observed that the manufacturing operator removed thy using thepw bo This action may create a risk of cross-contamination between nd is inconsistent with adequate aseptic gq handling techniques expected in controlled environments.
- Observation 4
Sampling plan not followed
Established sampling plan and test procedures are not followed. We reviewed the biometric access control system (eSSL Security at Fingertips) for thewe here I is located. and [gg samples are collected. We observed the following deficiencies: A. Oonpe your Quality Assurance employee ID: ®@1 7 documented in form QAS028-F07-00. Sampling Intimation Details, that he started collecting sample abe andbe sample However, the biometric access control system that limits access to the area (Room Block) does not show that employee IDRC entered that room during the sampling period. B. Similarly, onw® your Quality Assurance employee ID: documented in form QAS028-F07-00, Sampling [ntimation Details, that he started collectin, Nonetheless, the biometric access control system that limits access to the area (Room bo Block) does not show that employee ID: ®® entered that room during the sampling period. C. O our Quality Assurance employee ID: ®® 1 documented in form QAS028-F07-00, Sampling Intimation Details, that he started fhe sample at 9:4 1:11am. But the biometric access control system that limits access to the area (Room Block) shows that your employee ID: ®® entered the room at 9:41:28am. During my interview with your QA employee ID: @® = he explained that he always enters the sampling room via thew door, using the biometric access panel. performs we sampling by himself. and that the time it takes him from entering the room to start any gj sample collection is approximately | D. one your Quality Assurance employee IDP® documented in form QAS028-F07-00, Sampling Intimation Details, that he started collecting fale [8 mR mn Sg respectively. However. the biometric access control system that limits access to the area Block) shows that employee D2 entered the room at 12:52pm. During my interview with your QA employee 10:2 he explained that he always entered the room via the door. using the biometric access panel, that he always performs [fi sampling by himself. and that the time it takes him from entering the room to starting any fyaifisample collection is approximately ge lo © routine samples collected by your Quality Assurance (QA) personnel are tested by your Quality Control (QC) laboratory for microbiological analysis, Bacterial Endotoxin Test (BET), chemical analysis, and ge to ensure thatme meets established specifications for use in the manufacturing areasww of yourge ®® Blocks. Although these discrepancies were discussed with Quality Assurance managers, no investigation was initiated to determine why the Junior Executive QA employees were not physically present in the area during sample collection and to establish actions to prevent recurrence.
- Observation 5
BET testing deficiencies
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that in-process materials conform to appropriate standards of identity, strength, quality and purity. On November 17. 2025. we observed the preparation and reading of the Bacterial Endotoxin Test (BET) following your procedure titled “Bacterial Endotoxin Test by Gel Cloth Method", GTP Number: GTP009-01, Effective Date: March 15, 2025, and during our assessment the following deficiencies were identified: A. Your microbiologist performing the Bacterial Endotoxin Test (BET) gel formation reading for routine ee; sampling points: o® ®@ transferred the gel-clot sample tubes from the incubator to the waste container in a single rapid motion during microbiological analysis, without the crucial pause required to inspect the firmness of the gel for endotoxin detection. At the same time, a second QC Microbiologist/Analyst acting as a verifier. observed the primary microbiologist rapid assessment and verified the BET results at a distance and angle that failed to ensure that he could accurately observe and confirm the results at the time that the task was being performed and documented. Despite this basic deficiency, the secondary analyst signed off on the verification. B. For the BET gel formation reading for routine me the results of Positive Control (PC) and Product Positive Control (PPC) for samples o@ ®@ were invalid because no gel formation was observed. Your firm-initiated deviation number DEV/MB/25-014 on November 17, 2025, and identified that the root causes for the discrepant results were that the analyst missed a vial tap on the lysate prior to reconstitution and improper timing for rehydration. Deviation Report DEV/MB/25-014 is inadequate, since the identified causes lack scientific data to demonstrate that such analytical practices during sample preparation could alter the results and cause the deviation. According to your Microbiology Manager, during the preparation of the Control Standard Endotoxin Solution (CSE) for the BET, a minimum of ig time is required to ensure that the final concentration of the dilution is not affected (Positive Control). However, this critical step is not defined in your GTP Number: GTP009-01. Moreover, this fg time is not being recorded to ensure that it is always met. Since November 2023. your firm has approximately performed the BET on a total of ge sample sets. encompassin ma different sterile ma: products. © o@ intended for the U.S. market, and no discrepant/atypical/invalid results have been observed. Additionally. the QC Microbiology Analyst associated to Deviation Report DEV/MB/25-014 has performed this test for a total of approximately ma samples without any incident.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
Failure to meet specifications
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Show 6 more citations
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.
Identification of Person Performing the Testing
Laboratory records are deficient in that they do not include the initials and signature of the person performing the tests and the dates the tests were performed.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the sampling, testing, approval, and rejection of components, drug product containers, and closures.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Show 2 more citations
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Habits of good sanitation & health
Production personnel were not practicing good sanitation and health habits.
Written Procedures Not Followed
Written procedures are not followed for the receipt, handling, sampling, testing, and approval of components.
Buildings not maintained in good state of repair
Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on Apr 1, 2026. Each one asked for a Form 483.
Inspection ending Nov 27, 2025OAI
3 requests. In the inspection history above. FDA has posted its Form 483.
- Apr 1, 2026FDA-FOIA-2026-3260Form 483· 1 of 21 sitesClosed over fees
- Mar 11, 2026FDA-FOIA-2026-2372Form 483Records released
- Feb 5, 2026FDA-FOIA-2026-1249Form 483· 1 of 2 sitesRecords released
Inspection date not given
1 request. FDA released records in answer to a request for its Form 483 on Feb 11, 2026. FDAgent holds no copy that FDA posted.
- Dec 23, 2025FDA-FOIA-2025-14312Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.113Control of microbiological contamination3 of 3
- 21 CFR 211.80General requirements2 of 3
- 21 CFR 211.100Written procedures; deviations2 of 3
- 21 CFR 211.192Production record review2 of 3
- 21 CFR 211.194Laboratory records2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.28Personnel responsibilities1 of 3
- 21 CFR 211.42Design and construction features1 of 3
Show all 13
- 21 CFR 211.58Maintenance1 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.160General requirements1 of 3
- 21 CFR 211.165Testing and release for distribution1 of 3
- 21 CFR 314.81Other postmarketing reports1 of 3
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, sterilization
- Registration runs through
- Dec 31, 2027
- Registrant
- GCBC Pharma Private LimitedD-U-N-S 914234285
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names GCBC Pharma Private Limited (D-U-N-S 914234285) as the registrant for this site and the 2 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Gland Chemicals Private LimitedMalur, India · FEI 30002809913 inspections3latestDec 14, 2023NAINone on file
- Gland Chemicals Private LimitedAurangabad, India · FEI 30039834544 inspections4latestAug 7, 2018VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3008386908 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3008386908. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.