KRS Global Biotechnology, Inc
791 Park Of Commerce Blvd Ste 600, Boca Raton, Florida, United States
FEI 3006412304
FDA has 4 inspections on file for KRS Global Biotechnology, Inc in Boca Raton, Florida (FEI 3006412304), from 2014 to 2019. The latest ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Aug 20, 2019 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 14 citations from this inspection. They are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Seven regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 4, 2014–2019
- 2 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 4
- 4 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
- FDCA 503B(a)(10)
Container label, outsourcer facility
The container labels of your outsourcing facility's drug products are deficient.
Show 9 more citations
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to approve and reject all components, drug product containers, in process materials and drug products.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Components withheld from use pending release
Each lot of components is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Calibration/Inspection/Checking not done
Routine calibration of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- FDCA 503B(a)(10)
Drug product label, outsourcer facility
The labels of your outsourcing facility’s drug products are deficient.
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Show 1 more citation
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Clothing appropriate for duties performed
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Test methods
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features3 of 4
- 21 CFR 211.113Control of microbiological contamination3 of 4
- 21 CFR 211.165Testing and release for distribution3 of 4
- 21 CFR 211.28Personnel responsibilities2 of 4
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
- 21 CFR 211.63Equipment design, size, and location1 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 4
Show all 13
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 4
- 21 CFR 211.100Written procedures; deviations1 of 4
- 21 CFR 211.137Expiration dating1 of 4
- 21 CFR 211.167Special testing requirements1 of 4
- 21 CFR 211.198Complaint files1 of 4
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006412304 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006412304. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.