Acuity Specialty Products, Inc.
800 Development Ave, Chambersburg, Pennsylvania, United States
FEI 3006317477
FDA has 5 inspections on file for Acuity Specialty Products, Inc. in Chambersburg, Pennsylvania (FEI 3006317477), from 2009 to 2025. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 9 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Four of the five FOIA requests for this site have asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
16 regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 5, 2009–2025
- 1 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 5 of 5
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 5 requests, latest May 19, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration/Inspection/Checking not done
Routine calibration, inspection and checking of mechanical equipment is not performed according to a written program designed to assure proper performance.
Written program not followed
The written stability testing program is not followed.
Component identification test
Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.
Show 4 more citations
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written program not followed
The written stability testing program is not followed.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance20 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Drug product sample
Drug product samples are not representative of the entire batch.
Variation in the Amount of Components Used
The master production and control records are deficient in that they lack a justification for the variation in the amount of components used in the preparation of a dosage form.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded.
Establishment of calibration procedures
Procedures describing the calibration of instruments, apparatus, gauges and recording devices are deficiently written or followed.
Theoretical Yield and Percentages
The master production and control records are deficient in that they do not include a statement of theoretical yield and minimum, maximum, and yield percentages.
Show 15 more citations
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not reviewed and approved by the quality control unit.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
GMP Training Frequency
GMP training is not conducted on a continuing basis to assure that employees remain familiar with CGMP requirements applicable to them.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Reserve sample retention time
The retention period for drug product reserve samples (except those described in 211.170(b)(2) and (3)) is deficient in that they are not retained for one year after the expiration date of the drug product.
Training--operations, GMPs, written procedures
Employees are not given training in written procedures required by current good manufacturing practice regulations.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Documentation of Actual Yield and Theoretical Yield
The batch production and control records are deficient in that they do not include a statement of the percentage of theoretical yield.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Labeling control records including specimens or copies
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Containers Marked to Show Samples Taken
Containers from which samples have been taken are not marked to show that samples have been taken from them.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Variation in the Amount of Components Used
The master production and control records are deficient in that they lack a justification for the variation in the amount of components used in the preparation of a dosage form.
Theoretical Yield and Percentages
The master production and control records are deficient in that they do not include a statement of theoretical yield and minimum, maximum, and yield percentages.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
Show 8 more citations
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Documentation of Actual Yield and Theoretical Yield
The batch production and control records are deficient in that they do not include a statement of the.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Labeling control records including specimens or copies
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Five requests to FDA under the Freedom of Information Act named this site, most recently on May 19, 2026. Each one asked for a Form 483.
Inspection ending Mar 14, 2025OAI
4 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 11, 2025. FDAgent holds no copy that FDA posted.
- May 19, 2026FDA-FOIA-2026-5090Form 483· 1 of 5 sitesWithdrawn
- Sep 29, 2025FDA-FOIA-2025-11396Form 483· 1 of 4 sitesRecords released
- Jul 11, 2025FDA-FOIA-2025-8582Form 483Records released
- Jun 4, 2025FDA-FOIA-2025-7225Form 483· 1 of 5 sitesClosed
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Jun 23, 2025FDA-FOIA-2025-7930Form 483· 1 of 10 sitesWithdrawn
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 17 sections of 21 CFR in FDA’s published citations for this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance4 of 5
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures4 of 5
- 21 CFR 211.100Written procedures; deviations4 of 5
- 21 CFR 211.22Responsibilities of quality control unit3 of 5
- 21 CFR 211.166Stability testing3 of 5
- 21 CFR 211.180General requirements3 of 5
- 21 CFR 211.25Personnel qualifications2 of 5
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 5
Show all 17
- 21 CFR 211.160General requirements2 of 5
- 21 CFR 211.165Testing and release for distribution2 of 5
- 21 CFR 211.186Master production and control records2 of 5
- 21 CFR 211.188Batch production and control records2 of 5
- 21 CFR 211.192Production record review2 of 5
- 21 CFR 211.194Laboratory records2 of 5
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 5
- 21 CFR 211.137Expiration dating1 of 5
- 21 CFR 211.170Reserve samples1 of 5
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006317477 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006317477. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.