Novel Laboratories, Inc. d.b.a Lupin Somerset
400 Campus Dr, Somerset, New Jersey, United States
FEI 3006271438DUNS 793518643
FDA has 16 inspections on file for Novel Laboratories, Inc. d.b.a Lupin Somerset in Somerset, New Jersey (FEI 3006271438), from 2010 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the nine FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Nov 5, 2020. FDA issued a warning letter on (CDER · Office of Pharmaceutical Quality Operations Division I). 2 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.22(d), 21 CFR 211.192 and 21 CFR 211.42(c).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2027. Its registrant is Novel Laboratories Inc (D-U-N-S 793518643).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 16, 2010–2026
- 1 OAI · 11 VAI · 4 NAI
- Inspections with 483 observations shown
- 7 of 16
- Requested under FOIA
- 9 requests, latest Sep 1, 2026
- Import refusals
- 2 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
16 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Representative Samples Criteria
The number of containers to be sampled and amount of material taken from each container is not based upon appropriate criteria.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Design validation- Lack of or inadequate procedures
Procedures for design validation have not been adequately established.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 13 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate OOS investigations
OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the failure componentsto meet any of its specifications whether or not the batch has been already distributed. REPEAT OBSERVATION Specifically, A. OOS LAB00157, dated 4/16/2021, for (b)( ) an out of specification for (b)( ) impurity (b)( ). Lots of (b)( ) tablets manufactured in 2019. The cause was identified. It was hypothesized that the most probable cause for the OOS was moisture uptake when the bottle was opened for analysis. An initial FAR was filed on 4/21/21. The Phase I testing the same lot 8 months later. Your investigation did not test the retains of additional lots in 2019, which were still within expiry, to ensure they were within specification. The investigation did not evaluate if different packaging was needed (i.e. blister packs) containing (b)( ) tablets which was analyzed the same day, caused B. LAB00182, dated 9/9/2021, for Oxycodone (b)( ) out of specification for impurity (b)( ). January 2022. This sample represents (b)( ) lots confirmed on 9/9/2021 and no root cause identified. Batch S000268 was recalled. The remaining (b)( ) batches were not analyzed for compliance until two months later on 11/8/2021. C. LAB00197 and LAB00198, dated 11/8/2021 and 11/10/2021, for (b)( ) (expiry 7/2022) regarded out of expectation results being converted. OOS assay results obtained during re-analysis for (b)(4) in a joint packaging revalidation of (b)(4) was initiated on 11/12/21. The OOS was confirmed on 12/17/2021. (b)( ) produced after (b)( ) have been ongoing (+4 months) and batch is still on hold. D. No documented root cause investigation was initiated into the root cause of the system on 5/27/2021 and 6/23/2021. The (b)( ) solution and cleaning of equipment used in the manufacturing of Capsules, (b)(4) and (b)(4). E. There is no scientific justification for not investigating extraneous peaks which are less than the response of the swab sample. Extraneous peaks were noted during (b)( ) testing. The equipment was not recleaned and the source of the extraneous peaks was not investigated.
- Observation 2
Supplier, SAP, and change control gaps
OBSERVATION 2 The responsibilities and procedures applicable to (b)( ) are not adequate. Specifically, A. You have not documented the qualification of the contract packager. Although qualified for other products, (b)(4) contract packager starting in March 2021. NL-QA-013.6 Vendor Qualification, effective 7/7/2021 specifies an audit frequency for a contract packager. The Quality Agreement with them does not include (b)( ). The Director of Quality stated VPP-01780 Legacy Vendor Qualification Program, dated 7/7/2021, was approved to assess gaps in their supplier qualification program. Your firm is in the process to assess vendors against current expectations. These gaps are not reflected in any other quality system documents. The current tracker associated with VPP-01780 shows the contract packagers for (b)(4) (b)(4) tablets, and (b)(4) are currently not audited. B. Investigations into the SAP discrepancies are currently not being evaluated within Observation 8. The Associate Director of Supply Chain and Warehouse Operations stated material listed in the SAP system that wasn't physically present in the bin location was discovered approximately 4-6 weeks ago. The Associate Director of Supply Chain and Warehouse Operations stated he is working with SAP to fix the issue, but currently the investigation/evaluation is not documented. C. There is no procedure for the issuance and reconciliation of (b)( ) limited to equipment cleaning forms, preventative maintenance forms. D. Scientific justification could not be provided for not performing microbial testing on the following products: • (b)(4) • (b)(4) (b)( ) • (b)(4) tablets • (b)(4) • (b)(4) • (b)(4) • Capsules (b)(4) • (b)(4) (b)( ) mg • (b)(4) (b)( ) E. Change controls covering multiple documents do not contain sufficient detail or adequate evaluation of the change prior to implementation. Effectiveness checks are not performed. F. Implementation of switching to 100% verification for cleaning on non-dedicated equipment was not handled through a Quality System (i.e. deviation). This change was a commitment made during the FDA inspection. Instead, this change was verbally directed downward to mid-level managers in Quality then requested the swabs to be taken on a sample request. G. The location listed for USP raw material Lot# (b)( ) was not accurate in the SAP system. During a walkthrough on 03/09/2022, we observed that (b)( ) was placed on QA Hold due to Out of Specification (OOS) investigation LAB-00190; however, the SAP record shows the current storage location as "0101" which is the 190 control of the raw material Lot# (b)( ) which was put on "QA Hold".
Show observations 3 to 13
- Observation 3
Complaint handling not documented/followed
OBSERVATION 3 Procedures describing the handling of all written and oral complaints regarding a drug product are not written and followed. Specifically, your complaint SOP NL-QA-037.10 does not include instructions to initiate investigations when multiple complaints are received. For example, (b)( ) received twenty (20) market complaints for (b)( ) Batch (b)( ) (b)( ) and (b)( ) (11/2020 to 03/03/2022): (b)( ) is packaged in count bottles. The batch record specification for (b)( ) and your complaint reports state that market complaints for short/over bottle count for this batch are considered minor and no further actions are required. In addition, your firm received seven (7) and seventy-three (73) market complaints for short/over counts for (b)( ) and (b)( ) respectively regarding short/over counts (complaint dates ranged from ...). The firm received four (4) field alerts for empty capsules and did not adequately investigate.
- Observation 4
Incomplete training and OJT records
OBSERVATION 4 Employees engaged in the manufacture, processing and packing do not perform their assigned functions. REPEAT OBSERVATION Specifically, A. There are no records documenting On the Job Training (OJT) for all Operators hired prior to 01/2022. Your SOP No. NL-GN-009.5 "Personnel Training" Effective Date 08/16/2021 states Quality Assurance (QA) "Ensures that personnel have completed required on-the-job training and providing documentation releasing personnel to perform role/task"; however, QA does not have documentation to justify their release to perform GMP operations. B. Deviation from SOP No. NL-GN-009.5 Section 6 "training frequency" or as required, with such frequency to assure that personnel remain familiar with requirements is documented in an email instead of formal quality documentation. cGMP training for 2020 was replaced with (b)( ) through a company email; no quality documentation exists. C. Your training SOP No. NL-GN-009.5 does not outline actions when an "Unsuccessful" assessment is received by the trainee. Example: drums and pallets received an "Unsuccessful" training for (b)( ). A particular operator received an "Unsuccessful" assessment. The SOP "TRAINING OF STANDARD OPERATING PROCEDURES" Effective Date 01/04/2022 was in place; however, as of 03/10/2022 no retraining for the operator was documented after the assessment. In addition, the same operator received "Operation, Cleaning, Calibration and Preventive Maintenance of (b)( ) Solvent System" Effective Date 11/25/2020 approximately 14 months later, on 11/23/2021.
- Observation 5
Deficient cleaning/maintenance procedures
OBSERVATION 5 Procedures for the cleaning and maintenance of equipment, and materials used in the cleaning and maintenance operation, and the methods for disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance are not established and followed. Specifically, A. The operators do not document start/stop times, amounts and jets used during the cleaning of manufacturing equipment as per the firm's approved procedure. B. Gaps in cleaning of up to 14 days were noted during the cleaning Checklist for Liquid Manufacturing Tanks with 1 (b)( ) Capacity (b)( ) liters. On 12/20/2021, the operator executed cleaning using the exit valve. The operator did not continue; the tank is drained, closed the discharge valve of Tank A from (b)( ) on step (b) of a multi-step cleaning procedure. Starting on step (b) of the cleaning procedure the operator did not finish the validation. C. On 3/7/2022, during the walk-through of the (b)( ) cu.ft. (b)( ) (ID#0152) stated the last cleaning was 2/24/2022. This cleaning is listed as still in-process within the logbook. However, review of the cleaning checklist shows the only cleaning activity executed was identifying "Cleaned". As dirty hold time for this equipment is based on (b)( ) days, the logbook shows a hold time of 0 days instead of the (b)( ) days it should be. D. Your firm could not provide supporting documentation for protocol MVP-SOAP-CLN-LC and report MVR-SOAP-CLN-LC from 2007, which contain data on limit of detection, and accuracy/method precision. The amended in-house cleaning method (CL(b)( )(b) ) does not include actual validation of cleaning method for (b)( ).
- Observation 6
Inadequate sampling and campaign cleaning
OBSERVATION 6 Written procedures are not established and followed for utensils used in the manufacture, processing, packing, or holding of a drug product. REPEAT OBSERVATION Specifically, A. Determination of equipment sampling sites are not evaluated using a risk-based approach. The swab locations listed in SOP Form NL-VA-002-1.15 Locations are not based on a risk assessment to ensure the swab samples, used to verify the cleaning of equipment, are based on the hardest to clean areas. The Checklist for (b)( ) L (b)( ) (b)(4) is unclear whether the other locations are representative. The swab locations used to verify cleaning of the (b)( ) were insufficient. B. The studies in support of campaign cleaning (e.g., degradants or objectionable levels of microorganisms): 1. PRP-0264 Campaign Length Study Protocol for (b)( ) products for which you campaign was not performed prior to the final cleaning validation. 2. Campaign manufacturing was performed prior to studies of the previous campaigns to ensure the cleaning validation encompassed the campaign lengths. C. There is no procedure for cleaning of the (b)( ) equipment. This equipment was observed dirty during manufacture of (b)( ) drugs.
- Observation 7
Inadequate equipment design and qualification
OBSERVATION 7 Equipment used in the manufacture, processing, packing, or holding of a drug product is not of appropriate design to facilitate operations for its intended use. Specifically, (b)( ) A. Procedures for (b)( ) Cu.Ft (b)( ) and the discharge valve during (b)( ) process: On 03/07/2022, a drum was observed attached to the discharge/loading chute in Room (b)( ). The drum was left in this position; the operation of the equipment or process was not performed with appropriate controls. Issues were reported in drug product that were manufactured. B. 100% check-weigher machine ID No. 2017 used for (b)(4) filling, and (b)(4) Capsules (b)( ) was not calibrated for its intended use. Individual capsules verification between (b)(4) net (b)(4) g, using machine speed, and point weight verification at (b)( ) g was performed during the initial qualification. Machine speed was not verified during qualification. Your firm received about eight complaints for empty or underfilled capsules and submitted two field alerts for empty capsules. C. The (b)( ) system used to generate (b)( ) liquid and solid dosage drug products has deficiencies: 1. The first phase of the performance qualification specified in the approved protocol. The protocol identified sampling sites and point-of-use, except for the points before the (b) filter. Additional sites were identified, but only (b) sites were sampled and tested. The qualification was not performing the other sites. 2. Installation/operational qualification report states that the storage and distribution system was designed to feed with a set point of NLT (b)( ). A change control was issued to change (b)( ) to (b)( ). Another low loop supply and return flow alarm was observed. No justification was documented for the change in set point for both return and supply flow. 3. During the walkthrough of the (b)( ) system the (b)(4) flow meter on the (b)(4) was located before the filter on the distribution loop and was not examined. 4. On 08/30/2021, 08/31/2021, 10/20/2021, 11/11/2021, 01/06/2022 and 02/25/2022, the date and time of the Human Machine Interface (HMI) were not set to the correct date and time. A work order was issued but the performance of the system was not assessed. Sanitization was not assessed at the (b)(4) time set.
- Observation 8
SAP inventory and computer controls lacking
OBSERVATION 8 Input to and output from the computer and records are not properly controlled. Specifically, A. During the review of the last (b)(4) inventory reconciliation performed March 2021, the inventory was reconciled, material listed in SAP did not match physical quantities. This includes (b)( ) (b)( ). The review was not initiated. In addition, the label inventory is not reconciled and there is no procedure detailing the execution of the inventory reconciliation. B. On 3/9/2022, SAP listed 6 different materials (b)( ) TSE (b)(4) (b)( ). Only containers of (b)( ) were in storage. C. During a walk-through inspection of the warehouse (b)( ) were viewed in SAP to confirm the inventory balance. Two lots, although physically present on the pallet were listed as zero in SAP.
- Observation 9
Weak user access and system controls
OBSERVATION 9 Appropriate controls are not exercised over computers and/or control records or other records are instituted only in a limited manner. REPEAT OBSERVATION Specifically, A. One general UID and password is used for IT and Computer System Validation (CSV) departments to access the (b)(4) tablet tester which is used for the in-process check for (b)( ). The tester is used for the weight of the following products: (b)( ) (b)(4) tablets, (b)(4) ... Your SOP No. NL-IT-010.0 "GxP Computerized and Automated Systems User Access Management" Effective Date 06/12/2020 states that IT provides system access to users. During the walkthrough on 03/07/2022, we observed the user login for (b) (use for In-Process testing during compression) for Operators. Upon CT record verification, we observed that these Operators were missing from the user access list.
- Observation 10
Calibration and mapping not performed
OBSERVATION 10 Routine calibration, inspection and checking of equipment is not performed according to a written program designed to assure proper performance. Specifically, A. Stability chambers are not periodically temperature mapped and no procedure exists describing how and when to perform temperature mapping. Management stated temperature mapping is only performed during qualification. The CRT chambers (25°C/60%) were last qualified in 2014 and 2015. B. Weight sets ID# 3346, 3281, 3282, 3346 and 2085 used in the production area has an as found disposition value. The last recorded verification that these weight sets were found within tolerance was in June 2020. These scales and balances are routinely used for dispensing and weighing of materials and/or in-process samples.
- Observation 11
Inadequate laboratory method controls
OBSERVATION 11 Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling and finished drug products conform to appropriate standards of identity, strength, quality and purity. REPEAT OBSERVATION Specifically, A. The following discrepancies were noted during the review of the system used in the cleaning and manufacturing areas: 1. The firm's microbiological method has not demonstrated that the current practice derives statistically valid colony counts. CFUs were only detected on 27 plates. This method has not been validated at the firm or at the contract testing laboratory. 2. Action levels for (b)( ) are not scientifically justified and a trend/action level is not defined when the action level is exceeded. As the action level is set at (b)( ) CFUs, an investigation will only take place after the (b)( ) is out of specification. 3. The microbial flora of your (b)( ) has not been adequately used to identify microbial flora. Currently, identification only takes place after alert levels are exceeded. B. Your current analytical test methods for (b)( ) Tablets, (b)( ) Capsules, and (b)( ) are not adequately verified (Test Methods: FP-123-Ar-02, and FP-10f:AS-01 respectively). Methods such as USP and (b)( ) (Test Methods: RM-5043-AS-02 and RM-5053-AS respectively) do not include verification at the firm's site. Your firm's SOP No. NL-QC-040.05 "REQUIREMENTS" dated 05/07/2018 only requires (b)( ) individual sample reading of each assay analysts and does not include verification for finished products and APIs. C. Your firm's SOP No. NL-QC-113.0 "INTEGRATION OF DATA" Effective Date 09/29/2021 does not include instructions to routinely set multiple "Minimum area" and "Threshold" set for the processing method which inhibit integrations; the impurity integration events are not consistently processed for (b)( ) Capsules (Test Method FP-123-DEG-00).
- Observation 12
Incomplete laboratory data records
OBSERVATION 12 Laboratory records do not include complete data derived from all tests, examinations, and assay necessary to assure compliance with established specifications and standards. Specifically, injection and data reconciliations are not performed in the QC laboratory. Data reviewers only review what is printed for FTIR and there is no procedure for reconciliation of electronic data. There is no procedure for naming data files for FTIR. On 03/07/2022, during our review of FTIR #01 we observed unconventional file names without documentation that unconventional names are official samples and had been reviewed. Reviewers do not review electronic data for standalone equipment including but not limited to the Osmometer, Density Meter, and Viscometer. Review is conducted only of printed data.
- Observation 13
Unreliable stability program and storage
OBSERVATION 13 The written stability program for drug products does not include reliable, meaningful, and specific stability storage and testing conditions. Specifically, A. Stability samples are not stored in a manner to ensure proper air flow in the stability chambers. During a walk through inspection of the stability chambers on 3/10/2022 and 3/16/2022 we observed stability samples stored in (b)( ) lining the wire shelves on which stability samples were placed. There is no assurance that methods used during stability studies are able to determine specificity and detect all potential impurities. This applies to all commercial products manufactured at Lupin. B. NL-AR-005.4 Validation of Assay and Related Compounds Method describes the actions taken for specificity of methods used during stability studies. There is no assurance that these studies are able to detect all potential impurities as mass balance for all commercial products manufactured at Lupin.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate equipment cleaning and maintenance
OBSERVATION 1 Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, the firm's equipment cleaning and maintenance was found deficient. We observed several non-dedicated equipment utilized for the manufacturing of commercial drug products with 'cleaned' status label contaminated with powder residue and not properly maintained. Examples include, but are not limited to, the following observations made during the inspection: A. On 9/30/2020, during inspectional walkthrough of building Room # [illegible], we observed unknown white powder residue inside a [illegible] Equipment # 0235. The status label of the equipment was identified as "cleaned". Powder residue was observed at several locations inside the equipment including, but not limited to, [illegible]. The [illegible] were found with visible damage at several locations. The [illegible] duct and duct were found dirty with unknown powder residue. The firm stated that evaluation of [illegible] ducts are not part of routine maintenance activities and hence they were never dismantled since the machine was installed in 2008. This non-dedicated equipment is routinely utilized for the manufacturing of multiple products including Tinidazole Tablets, 250 mg & 500 mg, Trimethoprim Tablets, 100 mg and Voriconazole Tablets, 50 mg and 200 mg. B. On 10/1/2020, during inspectional walkthrough of building [illegible] we observed one used [illegible] without a unique identification number stored inside the clean equipment storage room. We observed black mold like appearance inside the [illegible]. The drum used for the storage of the [illegible] contained powder residue at the bottom. Based on the [illegible] cleaning procedure, the [illegible] should be product dedicated. The firm could neither confirm which product this belonged to nor provide any documented usage history. The [illegible] Equipment # 0235 is non-dedicated and utilized for the manufacturing of multiple products. C. On 10/21/2020, during inspectional walkthrough of building [illegible] we randomly selected about 10 trays out of [illegible] trays and observed white powder residue on at least 4 trays of these non-dedicated [illegible], Equipment # 0351 and 0352, used for the manufacturing of potent and non-potent products. The trays were stored as 'cleaned'. This non-dedicated equipment is utilized for the manufacturing of multiple products such as, but not limited to, Hydrocodone Bitartrate/Homatropine Methylbromide Tablets, 5 mg/1.5 mg, Phenelzine Sulfate Tablets, USP 15 mg and Methylergonovine Maleate Tablets, USP 0.2 mg. D. On 10/5/2020, during inspectional walkthrough of building [illegible], we observed a [illegible] filling machine, Equipment # 0247, with powder residue inside the segments for [illegible]. Rust-like material was found inside [illegible] tray used for the collection of capsules during filling operation. The status label of the machine was identified as "cleaned". This non-dedicated machine is routinely used for products such as, but not limited to, Temazepam Capsules, 15 mg and 30 mg; and Trimethobenzamide HCl Capsules, 300 mg. E. On 9/11/2020, we observed three [illegible] sampling tools without any unique identification number or associated log books stored inside the "Cleaned Equipment Storage Room" at building [illegible]. The QA technician stated that the tools are brand new and did not follow the "New equipment release procedure" before storing inside the manufacturing floor. We found unknown powder residue on the tip of a sampling tool. No log book was available to track the usage of these sampling tools. F. On 9/30/2020, during inspectional walkthrough of building we observed a [illegible] Equipment # 0837, stored with a status label as 'cleaned' dated '5/12/2020'. When the [illegible] was dismantled, approximately 50 ml o
Shortened here; the PDF has the full text.
- Observation 2
Failure to investigate OOS and deviations
OBSERVATION 2 REPEAT OBSERVATION There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. The firm's contract testing laboratory reported an OOS result of [illegible] ppb for TOC analysis (specification: NMT [illegible]) for [illegible] collected on 06/24/2019 from the [illegible] Site # located in manufacturing area of Building [illegible]. The firm failed to initiate an investigation for this OOS result until approximately 1 year later on a [illegible] (# LAB-00046) and concluded in the investigation report stating, "As per the investigation, a review of online TOC readings, for 06/23/2019, 06/24/2019 and 06/25/2019, revealed that the TOC readings were within limit. The root cause does not seem to be related to the operation of [illegible] system or method used for testing. It is more likely that the sample was contaminated during collection / transportation. Based on the acceptable results for other POU's, it can be concluded from the investigation that it is an isolated event and that the OOS TOC result was most likely due to sample contamination during collection / transportation. There was no impact as no product was processed with [illegible] from a [illegible] since the last passing TOC result." The Quality Unit failed to investigate the following: I. The Quality Unit failed to review the TOC print outs collected from the return loop [illegible]. The Quality Unit reviewed the [illegible] entered TOC data by the operators into the 'log book', book # 027 issued from 04/24/2019 to 09/17/2019 but never compared the accuracy with the print outs. A review of TOC print outs, which are the raw data of TOC readings, revealed that failed TOC results were disregarded, and incorrect data was entered into the logbook. This discrepancy was identified at the time of inspection. Reading as per Return loop On-line TOC Date analyzer print-out-Equipment# Action Limit-[illegible] 06/13/2019 [illegible] 06/20/2019 [illegible] 2. The Quality Unit failed to perform an impact assessment of all products manufactured at the facility during this period. A review of on-line TOC analyzer print-outs revealed multiple failures from 06/13/2019 to 07/26/2019 in the return loop of [illegible] Water System as shown below: Reading as per Return loop On-line TOC analyzer- Date Time [illegible] (Action Limit -- [illegible]) 06/13/2019 7:11 AM to 8:02 AM - [illegible] ppb 06/19/2019 8:15 AM to 10:38 AM [illegible] 06/20/2019 3:52 AM to 8:22 AM [illegible] ppb 07/1/2019 9:57 AM to 10:44 AM [illegible] ppb 07/26/2019 6:43 AM to 7:20 AM [illegible] 3. The Quality Unit shared the responsibility with Operations for the review of [illegible] Water analytical results received from the Contract Testing Laboratory. The OOS result received by the Validation Manager were not logged in and hence no investigation was initiated for [illegible] by the Quality Unit. B. OOS-19-023 was initiated on 06/13/2019 to probe the OOS results obtained during cleaning verification analysis associated with Orphenadrine Citrate ER Tablets, 100 mg USP, batch # S900734. Orphenadrine citrate residue results of [illegible] μg/swab for the [illegible], [illegible] μg/swab for [illegible] and [illegible] μg/swab for [illegible] samples of the [illegible] Tablet Press (Equipment ID# 0626), did not meet the established cleaning limit of NMT [illegible] μg/swab. The reinjection of the original vial and [illegible] samples confirmed the initial OOS and no assignable cause could be identified for the failure. During the review of chromatograms from initial analysis a peak was observed at run time ([illegible]) that was not integrated in sample swabbed from [illegible]. Also peak at [illegible] in [illegible] sample was not integrated. No further investigation was performed to identify the peaks. Multiple unknown peaks were also obs
Shortened here; the PDF has the full text.
Show observation 3
- Observation 3
Stability testing not completed on schedule
OBSERVATION 3 The written stability program is not followed. Specifically, analytical testing of the [illegible] stability batches is not completed as required under SOP (No. NL-ST-001.4, Administration of Stability Program, Effective Date: 2/6/2020). Section 6.10.1 of this SOP requires that testing of the stability samples must be completed within [illegible] of the pull date. However, as of 9/28/2020 stability testing of the following [illegible] batches is still pending. Days since Storage Scheduled Date Name of the Product Batch # Time Point pulled Condition pull date pulled and 9/28/2020 Nystatin Topical Powder, USP 100,000 Units/Gram S801331 Nystatin Topical Powder, USP 100,000 Units/Gram S800703 Nystatin Topical Powder, USP 100,000 Units/Gram M17023A Nystatin Topical Powder, USP 100,000 Units/Gram S900145 Nystatin Topical Powder, USP 100,000 Units/Gram S800290 Methylphenidate Hydrochloride Tablets, USP 10 mg CII S901607 Nystatin Topical Powder, USP 100,000 Units/Gram S901264 Nystatin Topical Powder, USP 100,000 Units/Gram S901265 Nystatin Topical Powder, USP 100,000 Units/Gram S900493 Nystatin Topical Powder, USP 100,000 Units/Gram S900492 (b) (4) (Long Term) Other deficiencies observed in stability testing include: - Approximately [illegible] stability samples were not tested within the [illegible] period. - Approximately [illegible] samples were tested [illegible] days after the scheduled test completion date. Most of the batches in the aforementioned table are [illegible] stability batches that represent the actual product in the market. During the year of 2019, the site manufactured Nystatin commercial batches as below: Product Info Batch No. Expiry date [illegible]
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch Monitoring3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Timely submission
An annual report was not submitted within 60 days of the anniversary date of U.S. approval of the application to the FDA division responsible for reviewing the application.
Late submission of quarterly safety reports
Not all quarterly periodic adverse drug experience reports have been submitted within 30 days of the close of the quarter.
Late submission of annual safety reports
Not all annual periodic adverse drug experience reports have been submitted within 60 days of the anniversary date of the approval of the application.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Defined areas of adequate size for operations
The control systems necessary to prevent contamination or mix-ups are deficient.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure and followed.
Complaint Investigation/Follow-Up Findings
Complaint records are deficient in that they do not include the findings of the investigation and follow-up.
Show 8 more citations
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Defined areas of adequate size for operations
The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.
No written record of investigation
Written records are not always made of investigations into the failure of a batch or any of its components to meet specifications.
Failure to meet specifications
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application.
Written record of complaint to include findings, follow-up
Written records of investigation of a drug complaint do not include the follow-up.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are not written or followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Nine requests to FDA under the Freedom of Information Act named this site, most recently on Sep 1, 2026. Each one asked for a Form 483.
Inspection ending Apr 17, 2026VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jun 9, 2026FDA-FOIA-2026-5642Form 483· 1 of 5 sitesRecords released
Inspection ending Oct 10, 2025VAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Feb 10, 2026. FDAgent holds no copy that FDA posted.
- Sep 1, 2026FDA-FOIA-2026-8500Form 483Records released
- Dec 9, 2025FDA-FOIA-2025-13723Form 483· 1 of 5 sitesRecords released
Inspection ending May 17, 2024NAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Aug 27, 2026. FDAgent holds no copy that FDA posted.
- Sep 1, 2026FDA-FOIA-2026-8501Form 483Open
- Aug 21, 2026FDA-FOIA-2026-8111Form 483Records released
- Jul 31, 2024FDA-FOIA-2024-6655Form 483· 1 of 2 sitesClosed
Inspection ending Nov 5, 2020OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jan 12, 2021FDA-FOIA-2021-267Form 483Closed
Inspection date not given
2 requests. FDA released records in answer to a request for its Form 483 on Nov 17, 2025. FDAgent holds no copy that FDA posted.
- Nov 3, 2025FDA-FOIA-2025-12549Form 483Records released
- Oct 6, 2020FDA-FOIA-2020-7099Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 15 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 16 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit3 of 5
- 21 CFR 211.42Design and construction features2 of 5
- 21 CFR 211.192Production record review2 of 5
- 21 CFR 314.81Other postmarketing reports2 of 5
- 21 CFR 211.25Personnel qualifications1 of 5
- 21 CFR 211.63Equipment design, size, and location1 of 5
- 21 CFR 211.67Equipment cleaning and maintenance1 of 5
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 5
Show all 15
- 21 CFR 211.100Written procedures; deviations1 of 5
- 21 CFR 211.137Expiration dating1 of 5
- 21 CFR 211.165Testing and release for distribution1 of 5
- 21 CFR 211.186Master production and control records1 of 5
- 21 CFR 211.198Complaint files1 of 5
- 21 CFR 314.80Postmarketing reporting of adverse drug experiences1 of 5
- 21 CFR 820.30Design controls1 of 5
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Office of Pharmaceutical Quality Operations Division I · DrugsLetter on fda.govFDA record
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3006271438, one row per refused product line.
2 refusals on 2022-01-10 · charged UNAPPROVED on 2 · no FDA sample analysis
FDA firm profile- 2022-01-10
SUPPRESSANT N.E.C.66FDA99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-6671732-3/11/8
- 2022-01-10
SUPPRESSANT N.E.C.66FDE99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-6671732-3/11/7
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Novel Laboratories IncD-U-N-S 793518643
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006271438 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006271438. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.