Skip to content

Products By O2, Inc

4950 W Prospect Rd, Fort Lauderdale, Florida, United States

FEI 3005835723DUNS 136932444

FDA has 2 inspections on file for Products By O2, Inc in Fort Lauderdale, Florida (FEI 3005835723), from 2017 to 2023. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 11 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One FOIA request has asked FDA for this inspection's records.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is Products by O2, Inc. (D-U-N-S 136932444).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2017–2023
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
1 request, latest Sep 21, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance11 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Label storage access limited to authorized personnel

      Access to the storage area for labels and labeling materials is not limited to authorized personnel.

    2. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    3. Changes to Procedures Not Reviewed, Approved

      Changes to written procedures are not reviewed and approved by the quality control unit.

    4. Washing and toilet facilities are deficient

      Washing and toilet facilities lack hot and cold water.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components conform to appropriate standards of identity, strength, quality and purity.

    Show 6 more citations
    1. Written procedures not established/followed

      Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    2. Reserve samples identified, representative, stored

      Reserve drug product samples are not retained and stored under conditions consistent with product labeling.

    3. Approval and review of procedures

      Written procedures are not drafted, reviewed and approved by the appropriate organizational units.

    4. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use.

    5. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    6. Component identification test

      Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    2. Description of containers, labels, et. al.

      Master production and control records lack a description of the drug product containers, closures and packaging materials, a specimen or copy of each label and all other labeling and the signatures and dates entered by the person or persons responsible for the approval of labeling.

    3. Written records kept in individual logs

      Written records of major equipment are not included in individual equipment logs.

    4. Components withheld from use pending release

      Each lot of is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.

    5. Cleaning SOPs/instructions

      Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Sep 21, 2026.

  • Inspection ending Oct 23, 2023OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Sep 21, 2026FDA-FOIA-2026-9150EIRWithdrawn

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 13 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.

Show all 13

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2027
Registrant
Products by O2, Inc.D-U-N-S 136932444

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005835723 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005835723. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.