Best Sanitizers Inc
154 Mullen Dr, Walton, Kentucky, United States
FEI 3005763425DUNS 627278224
FDA has 6 inspections on file for Best Sanitizers Inc in Walton, Kentucky (FEI 3005763425), from 2009 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.166(a), 21 CFR 211.192 and 21 CFR 211.68(a).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and API manufacturing, through Dec 31, 2026. Its registrant is Best Sanitizers, Inc (D-U-N-S 627278224).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2009–2026
- 0 OAI · 5 VAI · 1 NAI
- Inspections with 483 observations shown
- 5 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest Jul 24, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.
input/output verification
Input to and output from the computer and records or data are not checked for accuracy.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Written program not followed
The written stability testing program is not followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.
Calibration/Inspection/Checking not done
Routine inspection and checking of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Purchasing controls, Lack of or inadequate procedures
Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements have not been adequately established.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Documentation of Batch Investigations
The batch production and control records are deficient in that they do not include documentation of batch investigations performed.
Calibration/Inspection/Checking not done
Routine inspection and checking of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed .
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Show 2 more citations
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Returned drug procedures in writing and followed
Procedures describing the holding and testing and reprocessing of returned drug products are not in writing .
- NAINo objectionable conditions that need follow-upDevices · Compliance: Devices7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Habits of good sanitation & health
Production personnel were not practicing good sanitation and health habits.
Following/documenting laboratory controls
Established laboratory control mechanisms are not documented at the time of performance.
Show 2 more citations
Reserve samples identified, representative, stored
Reserve drug product samples are not appropriately identified.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Jul 24, 2026. It asked for a Form 483.
Inspection ending May 1, 2026VAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 29, 2026. FDAgent holds no copy that FDA posted.
- Jul 24, 2026FDA-FOIA-2026-7132Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 17 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.68Automatic, mechanical, and electronic equipment3 of 5
- 21 CFR 211.67Equipment cleaning and maintenance2 of 5
- 21 CFR 211.160General requirements2 of 5
- 21 CFR 211.166Stability testing2 of 5
- 21 CFR 211.192Production record review2 of 5
- 21 CFR 211.28Personnel responsibilities1 of 5
- 21 CFR 211.100Written procedures; deviations1 of 5
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 5
Show all 17
- 21 CFR 211.125Labeling issuance1 of 5
- 21 CFR 211.170Reserve samples1 of 5
- 21 CFR 211.180General requirements1 of 5
- 21 CFR 211.182Equipment cleaning and use log1 of 5
- 21 CFR 211.188Batch production and control records1 of 5
- 21 CFR 211.194Laboratory records1 of 5
- 21 CFR 211.198Complaint files1 of 5
- 21 CFR 211.204Returned drug products1 of 5
- 21 CFR 820.50Purchasing controls1 of 5
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- Best Sanitizers, IncD-U-N-S 627278224
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3005763425 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3005763425. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.