Skip to content

MBi Distributing Inc. dba MBi Nutraceuticals

211 N 1800 W, Lindon, Utah, United States

FEI 3005482889

FDA has one inspection on file for MBi Distributing Inc. dba MBi Nutraceuticals in Lindon, Utah (FEI 3005482889). It ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2018
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written records kept in individual logs

      Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.

    2. Establish reliability of supplier's C of A

      Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.

    3. Component Test Records

      The component records do not include the results of tests or examinations performed and the conclusions derived from tests or examinations performed.

    4. Complete Test Data

      Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.

    5. Individual inventory record

      Records fail to include an individual inventory record of each component and reconciliation of the use of each component with sufficient information to allow determination of any associated batch or lot of drug product.

    Show 7 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    2. Written procedures not established/followed

      Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Strict control not exercised over labeling issued

      Strict control is not exercised over labeling issued for use in drug product labeling operations.

    4. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

    5. Homeopathic drugs, assessment of stability

      There is no written assessment of stability of homeopathic drug products based at least on testing or examination of the drug product for compatibility of the ingredients and marketing experience with the drug product to indicate that there is no degradation of the product for the normal or expected period of use.

    6. Calibration/Inspection/Checking not done

      Routine calibration, inspection and checking of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.

    7. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 11

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005482889 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005482889. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.