Skip to content

Pharbest Pharmaceuticals, Inc.

14 Engineers Ln, Farmingdale, New York, United States

FEI 3005382247DUNS 557054835

FDA has 8 inspections on file for Pharbest Pharmaceuticals, Inc. in Farmingdale, New York (FEI 3005382247), from 2010 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 8 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two FOIA requests have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

11 regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis and repacking, through Dec 31, 2026. Its registrant is Pharbest Pharmaceuticals, Inc. (D-U-N-S 557054835).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
8, 2010–2025
0 OAI · 7 VAI · 1 NAI
Inspections with 483 observations shown
7 of 8
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
2 requests, latest May 4, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Annual visual exams of drug products

      Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.

    2. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested nor are records of such data maintained to determine an appropriate expiration date.

    3. Calibration/Inspection/Checking not done

      Routine calibration, inspection and checking of mechanical equipment is not performed according to a written program designed to assure proper performance.

    4. Review of problem drugs

      The procedures for the annual quality standards record evaluation are deficient in that they do not address a review of records for each drug product.

    5. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    Show 3 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    2. Establishment of calibration procedures

      Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed.

    3. Written record not kept of program and validation data

      A written record of the program along with appropriate validation data has not been maintained in situations where backup data is eliminated by computerization or other automated processes.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.

    2. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.

    3. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used and description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance.

    4. Calibration/Inspection/Checking not done

      Routine inspection and checking of electronic equipment is not performed according to a written program designed to assure proper performance.

    5. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    Show 2 more citations
    1. Defined areas of adequate size for operations

      The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.

    2. Laboratory equipment calibration records

      Laboratory records do not include complete records of the periodic calibration of laboratory instruments and apparatus.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Calibration/Inspection/Checking not done

      Routine inspection and checking of electronic equipment is not performed according to a written program designed to assure proper performance.

    2. Defined areas of adequate size for operations

      The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.

    3. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    4. Reserve samples identified, representative, stored

      Reserve drug product samples are not appropriately identified, representative of each lot or batch of drug product and retained and stored under conditions consistent with product labeling.

    5. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    Show 1 more citation
    1. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Storage under appropriate conditions

      Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.

    2. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    3. Drug products - samples representative, identified properly

      Samples taken of drug products for determination of conformance to written specifications are not properly identified.

    4. Status of Each Lot Identified

      Each lot of components was not appropriately identified as to its status in terms of being quarantined, approved or rejected.

    5. Identification of Each Lot in Each Shipment

      Each lot in each shipment received was not identified with a distinctive code for each container or grouping of containers for components.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Adequate lighting not provided

      Adequate lighting is not provided in all areas.

    2. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    3. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.

    4. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

    5. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not followed.

    Show 1 more citation
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    2. In-process materials - sampling, testing procedures

      Laboratory controls do not include a description of testing procedures for in-process materials.

    3. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    4. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    2. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    3. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    4. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate standards designed to assure that conform to appropriate standards of identity, strength, quality and purity.

    Show 4 more citations
    1. Annual visual exams of drug products

      Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.

    2. Accelerated stability studies

      Accelerated stability studies, combined with basic stability information, used to support tentative expiration dates are not supported with ongoing full shelf life studies.

    3. Records reviewed annually

      Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.

    4. Instruments, apparatus, et. al. not meeting specs

      The use of apparatus not meeting established specifications was observed.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on May 4, 2026. Each one asked for a Form 483.

  • Inspection ending Sep 15, 2025VAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Dec 8, 2025. FDAgent holds no copy that FDA posted.

    1. May 4, 2026FDA-FOIA-2026-4375Form 483· 1 of 5 sitesWithdrawn
    2. Nov 18, 2025FDA-FOIA-2025-13118Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 17 sections of 21 CFR in FDA’s published citations for 7 of this facility’s 8 inspections, with how many of them cited each.

Show all 17

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis, repacking
Registration runs through
Dec 31, 2026
Registrant
Pharbest Pharmaceuticals, Inc.D-U-N-S 557054835

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005382247 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005382247. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.