Skip to content

Colorlab Cosmetics, Inc.

110 Pioneer Dr, Williston, Vermont, United States

FEI 3005000375

FDA has one inspection on file for Colorlab Cosmetics, Inc. in Williston, Vermont (FEI 3005000375). It ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 18 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2022
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance18 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    2. Batches Formulated to less than 100%

      Written production and control procedures include batches formulated with the intent to provide less than 100 percent of the labeled or established amount of active ingredient.

    3. No written record of investigation

      Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.

    4. Distinctive ID or code not recorded in batch record

      The batch records do not record the distinctive identification number, code and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.

    5. Calibration/Inspection/Checking not done

      Routine calibration and checking of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.

    Show 13 more citations
    1. Mfg / Processing Operations Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.

    2. Lack of quality control unit

      There is no quality control unit.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function.

    4. Written in-process control procedures

      Written procedures are not established that describe the in-process controls, tests and examinations to be conducted on appropriate samples of in-process materials of each batch.

    5. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

    6. Written records kept in individual logs

      Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.

    7. Component release checked by 2nd person

      Each container of component dispensed to manufacturing is not examined by a second person to assure that the component was released by the quality control unit, the weight or measure is correct as stated in the batch records and the containers are properly identified.

    8. Written sanitation procedures lacking

      There is a lack of written procedures assigning responsibility, providing cleaning schedules and describing in sufficient detail the methods, equipment and materials to be used for sanitation.

    9. Cleaning/maintenance records not kept

      Records are not kept for the cleaning and inspection of equipment.

    10. Drains--Size, Back-siphonage Prevention

      Drains are not provided with an air break or other mechanical device to prevent back-siphonage where connected directly with a sewer.

    11. Examination of packaging and labeling

      Examination of packaging and labeling materials for suitability and correctness before packaging operations is not documented in the batch production records.

    12. Component identification test

      Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.

    13. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

Regulations FDA cited here

The 15 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 15

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005000375 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005000375. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.