LEC Custom Products, Inc.
7 Kenview Blvd, Brampton, Canada
FEI 3004737602
FDA has 4 inspections on file for LEC Custom Products, Inc. in Brampton, Canada (FEI 3004737602), from 2011 to 2020. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 22 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
14 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 4, 2011–2020
- 1 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 4
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- 14 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance22 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written in-process control procedures
Written procedures are not established and followed that describe the in-process controls, tests and examinations to be conducted on appropriate samples of in-process materials of each batch.
Measured components for manufacturing
Components for drug product manufacturing are not weighed and measured.
Distribution Recall System
The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary.
Identification of Each Lot in Each Shipment
Each lot in each shipment received was not identified with a distinctive code for each container or grouping of containers for components, drug product containers and closures.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Show 17 more citations
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to approve and reject all drug product containers, closures, in process materials and drug products.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established, written and followed.
Status of Each Lot Identified
Each lot of components, drug product containers and closures was not appropriately identified as to its status in terms of being quarantined, approved or rejected.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Following/documenting laboratory controls
Established specifications, sampling plans, test procedures and laboratory control mechanisms are not followed and documented at the time of performance.
Calibration/Inspection/Checking not done
Routine calibration and checking of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Handling and Storage to Prevent Contamination
There was a failure to handle and store components at all times in a manner to prevent contamination.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing and packing.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.
Identification of Persons Performing Significant Steps
The batch production and control records are deficient in that they do not include identification of persons performing each significant step in the operation.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing and packaging of the drug product.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred.
Batches Formulated to less than 100%
Written production and control procedures include batches formulated with the intent to provide less than 100 percent of the labeled or established amount of active ingredient.
Lack of quality control unit
There is no quality control unit.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration/Inspection/Checking not done
Routine calibration, inspection and checking of electronic equipment is not performed according to a written program designed to assure proper performance.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Testing Each Component for Conformity with Specs
Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Show 5 more citations
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Verification of component addition
Each component is not added to the batch by one person and verified by a second person..
In-process materials characteristics testing
In-process materials are not tested for identity, strength, quality and purity and approved or rejected by the quality control unit during the production process and after storage for long periods.
Mfg / Processing Operations Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Regulations FDA cited here
The 18 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.25Personnel qualifications2 of 2
- 21 CFR 211.67Equipment cleaning and maintenance2 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 2
- 21 CFR 211.101Charge-in of components2 of 2
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 2
- 21 CFR 211.166Stability testing2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
Show all 18
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.80General requirements1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.103Calculation of yield1 of 2
- 21 CFR 211.150Distribution procedures1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.182Equipment cleaning and use log1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
- 21 CFR 211.192Production record review1 of 2
- 21 CFR 211.198Complaint files1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004737602, one row per refused product line.
14 refusals from 2020-08-10 to 2020-11-17 · charged DRUG GMPS on 14 · no FDA sample analysis
FDA firm profile- 2020-11-17
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8381228-8/31/4
- 2020-11-17
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8381228-8/31/3
- 2020-11-17
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8381228-8/31/2
- 2020-11-17
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8381228-8/21/1
- 2020-09-01
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8377717-6/11/1
Show 9 more
- 2020-09-01
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8361233-2/11/2
- 2020-09-01
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8361233-2/11/1
- 2020-09-01
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8105317-4/11/1
- 2020-08-20
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8276581-8/21/3
- 2020-08-20
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8276581-8/21/2
- 2020-08-20
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8276581-8/21/1
- 2020-08-20
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8267297-2/11/1
- 2020-08-10
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8107256-2/11/2
- 2020-08-10
DENTAL PROTECTANT N.E.C.63SBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports799-8107256-2/11/1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004737602 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004737602. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.