Skip to content

Legacy Pharmaceutical Packaging LLC

13333 Lakefront Dr, Earth City, Missouri, United States

FEI 3004453700

FDA has 15 inspections on file for Legacy Pharmaceutical Packaging LLC in Earth City, Missouri (FEI 3004453700), from 2010 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.

The most recent OAI inspection ended on Jun 30, 2023. FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations III). No court action or import refusal is filed under this FEI.

Five regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
15, 2010–2024
2 OAI · 12 VAI · 1 NAI
Inspections with 483 observations shown
10 of 15
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
5 requests, latest Aug 10, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

15 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    2. Packaging line inspection before use

      Inspection of the packaging and labeling facilities immediately before use is not done to assure that all drug products have been removed from previous operations.

    3. Training , Education , Experience overall

      Employees engaged in the packing of a drug product lack the training required to perform their assigned functions.

    4. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

    5. Calibration/Inspection/Checking not done

      Routine calibration and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.

    Show 1 more citation
    1. Written procedures not established/followed

      Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

  3. NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: DevicesPosted 483 · 2 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Software validation for automated processes

      Software used as part of the quality system has not been adequately validated for its intended use according to an established protocol.

    2. Lack of or inadequate procedures

      Procedures for corrective and preventive action have not been established.

  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: DevicesPosted 483 · 5 observations
    Not in FDA’s current Data Dashboard list (checked Nov 19, 2026)

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate validation of vision system

      A process whose results cannot be fully verified by subsequent inspection and test has not been adequately validated according to established procedures. Specifically, the following was noted from review of the Final Report for Performance Qualification for Packaging 1 (5) (4), dated on or about 12/23/19: A. The process control verification protocol (QP 19-416, -417 and -418, part 8.0) documents the Vision System Challenge tests for incorrect/illegible carton part code and/or UDI barcode on the carton label was a critical quality classification. The final report (part 4.0) reads as follows: "***All PQ tests of the *** Vision System with *** camera and critical quality attribute checks were performed, verified and demonstrated to meet all acceptance criteria***". I. However, the vision system challenge as described in part 9 of the I (o) (4) packaging instructions (Document Number MBR-06U2, revision 01), does not include using a challenge carton with either an incorrect carton part code or incorrect UDI barcode. The packaging project manager stated the optical character recognition (OCR) capability of the vision system was never tested (challenged) to detect and reject incorrect part codes or incorrect UDI barcodes during any of the I (6) (4) performance qualification (PQ) lots. II. He said the vision system was challenged for "missing / illegible codes," only. The challenge devices for missing / illegible codes were not a controlled/standardized set of test articles used for all performance qualification (PQ) lot tests. The test articles were [illegible] to each challenge of each lot (15) (4) vision challenges were performed per lot. B. The final report (part 5.0) reads: "There were no exceptions initiated during the execution of the PQ protocols". However the following occurred and were not included in the final PQ evaluation: 1. Maintenance was required to adjust the vision system during (o) (4) production lot number I (I>) (4). The engineering technician said he adjusted [illegible] on the vision system because the system was rejecting too many packages. This maintenance activity was not documented or evaluated as a process exception in the final report. II. Vision system labeling rejects was a stated critical quality attribute check for the performance qualification; however the number of labeling rejects (nonconformances) detected were not recorded or evaluated as process exceptions in the final report. III. The packaging project manager stated rejected/mislabeled cartons were reworked during (15) (4) of the production lots. However, the amount of rework was not recorded or included in the final report as process exceptions.

    2. Observation 2

      Rework not documented in device history

      Rework and reevaluation activities have not been documented in the device history record. Specifically, the packaging project manager said mislabeled packages were rejected in I (o) (4) performance qualification production lots. He said the contents I (6) (4) were removed from the rejected cartons and reused. The mislabeled packages were destroyed. There was no documentation in the device history records for the I (ID-:=-@1) performance qualification lots of any rework or reevaluation of the rejected package components. Lot numbers for the performance qualifications were [illegible].

    Show observations 3 to 5
    1. Observation 3

      No procedures for nonconforming product

      Procedures have not been adequately established to control product that does not conform to specified requirements. Specifically, the vision system is intended to detect rejected packages for lot numbers and bar codes that are either missing or inaccurate. The packaging project manager stated the optical system detected failures (rejects) of labeling non-conformances during production of (o) (4) of the performance qualification lots. The number of labeling rejections (nonconformances) detected during the PQ production runs were not recorded. A. There were no reports documenting the identification, documentation, evaluation, segregation, and disposition of nonconforming products. B. There was no documentation of an evaluation of nonconformance to include a determination of the need for an investigation and notification of the persons or organizations responsible for the nonconformance.

    2. Observation 4

      Maintenance schedules and records lacking

      Schedules for the adjustment, cleaning, and other maintenance of equipment have not been adequately established. Specifically, maintenance activities, including the reason (problem), maintenance performed, date and individual(s) performing the maintenance activities, were not documented when maintenance was accomplished on the vision system for performance qualification lot numberi (5) (4).

    3. Observation 5

      Inadequate complaint handling procedures

      Procedures for receiving, reviewing, and evaluating complaints by a formally designated unit have not been adequately established. Specifically, Legacy does not have complaint procedures that ensure complaints are evaluated for MDR reportability.

  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

    2. Records reviewed annually

      Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.

    3. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Specific information required in individual logs

      Individual equipment logs do not show time, date, product, and lot number of each batch processed.

    2. Chronological Order of Equipment Log Entries

      The entries in the equipment cleaning and use logs are not in chronological order.

    3. Reprocessing procedures not written or followed

      Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not written and followed.

    4. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.

    5. SOPs not followed / documented

      Written production and process control procedures are not documented at the time of performance.

    Show 2 more citations
    1. Calibration/Inspection/Checking not done

      Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.

    2. In-process materials specifications

      In-process specifications are not consistent with drug product final specifications.

  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Changes to Procedures Not Reviewed, Approved

      Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit and reviewed and approved by the quality control unit.

    2. Approve or reject procedures or specs

      The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, and quality of drug products.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    4. Extent of discrepancy, failure investigations

      Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.

    5. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

    Show 1 more citation
    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

  10. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  11. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.

    2. SOPs not followed / documented

      Written production and process control procedures are not documented at the time of performance.

    3. No written record of investigation

      Written records are not always made of investigations into unexplained discrepancies.

    4. Sampling/testing of labeling/packaging materials

      Labeling and packaging materials are not examined upon receipt and before use in packaging and labeling of a drug product.

    5. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    Show 1 more citation
    1. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not followed.

  12. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Quarantine Storage of Components

      Incoming components, drug product containers, and closures are not stored under quarantine until they have been tested or examined, as appropriate, and released.

    2. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

    3. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the identification and testing of components.

    4. Quarantine - actual practice

      Drug products are not quarantined before being released by the quality control unit.

    5. Quarantine of Rejected Components et. al.

      Rejected components are not controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.

    Show 2 more citations
    1. Training , Education , Experience overall

      Employees engaged in the manufacture, processing, and packing of a drug product lack the training required to perform their assigned functions.

    2. Deviations from laboratory control requirements

      Deviations from written specifications and standards are not recorded and justified.

  13. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Documentation of Sampling Performed

      The batch production and control records are deficient in that they do not include documentation of sampling performed.

  14. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  15. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Review of representative number of batches

      Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    2. Procedures to be written and followed

      Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on Aug 10, 2026. Each one asked for a Form 483.

  • Inspection ending Jun 30, 2023OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jul 22, 2024FDA-FOIA-2024-6427Form 483Closed
  • Inspection ending Jun 20, 2023NAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Aug 10, 2026FDA-FOIA-2026-7654Form 483· 1 of 5 sitesRecords released
    2. May 5, 2025FDA-FOIA-2025-3966Form 483· 1 of 4 sitesClosed
  • Inspection ending Apr 27, 2022OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jul 22, 2024FDA-FOIA-2024-6426Form 483Closed
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Sep 12, 2022FDA-FOIA-2022-6528Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 22 sections of 21 CFR in FDA’s published citations for 9 of this facility’s 15 inspections, with how many of them cited each.

Show all 22

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004453700 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004453700. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.